Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Confirmation Test.Part

An indication of the minimum size of a subsample can be obtained by using the concept of a sampling constant. For example, in the laboratory, the sampling constant can be used to estimate the minimum size of the test portion. However, the suitability of the chosen test portion size must be confirmed as part of method validation. The sampling constant Ks has units of mass. This is the mass of the test portion necessary to ensure a relative subsampling error of 1% (at the 68% confidence level) in a single determination. The value of /Ks is numerically equal to the coefficient of variation, CV (see Chapter 6, Section 6.1.3) for results obtained on 1 g subsamples in a procedure with insignificant analytical error. [Pg.42]

The use of the hemicellulose fraction of wood offers great promise. Some of the results reported herein have been reported in preliminary reports (43) and confirmed in part in other species (I, 4, 8, 39, 42). Hemicellulose can be ammoniated (37). Other wood by-products have been tested with generally favorable results (18). Other reports of this symposium cover these aspects. [Pg.319]

After a plant trip test, Monju restarted operation on 6th December 1995. On 8th December, power was being raised for the next plant trip tests, part of 40% electric power tests. The thermal power had reached 43% when an alarm sounded at 19 47 dueto an off-scale sodium temperature at the outlet of IHX in the secondary circuit loop C. Afire alarm (smoke detector) sounded at the same time. A sodium leak alarm in the secondary circuit followed. The plant conditions of Monju at that time are shown in Fig. 1. The presence of smoke was confirmed when the door of the piping room was opened. The plant operators decided to begin normal shutdown operations becausethey judged it was a small sodium leak had occurred. Reactor power-down operations began at 20 00. [Pg.45]

A BAT can conduct hoth alcohol screening and confirmation tests if he/she meets specific training requirements. The BAT must he knowledgeable about the Part 40 alcohol testing procedures and current Department of Transportation (DOT) guidance. [Pg.37]

Seiko-Epson also investigated utilizing Sn-Ag-Cu to attach area array packages such as EGAs and CSPs. ATC testing (-40 °C to 125°C, 30 min/cycle) confirmed that parts attached with Sn-Ag-Cu exhibited more than three times the fatigue life compared to conventional eutectic Sn-Pb solder. [Pg.658]

Figure 1 compares the results from computer simulations with physical tests for center latch configuration. Computer simulations predicted the seat back to pass the ECE 17 requirements, which is confirmed with the actual test. No signs of cracking, tearing, or any other kind of failirre were observed in the tested parts. [Pg.751]

No emission during holds was observed but the concentration of events in clusters and the high level of amplitude of events confirmed the results of the proof test. After 20 bars, the bottom of the vessel around the defect became silent and activity is observed in the high part of the vessel near welds. [Pg.55]

This approach has not been tested for any dusts that bum heterogeneously such as some metal dusts (A-6-1.2). Also, this large an effect of temperature has not been found by some other workers, it has yet to be confirmed that the effect is not due in part to loss of moisture (6-1.6) or evolution of flammable gas (6-1.3), both of which can have large effects on MIE. [Pg.177]

Berth operator should possess a supplier s certificate for any hose forming part of the pipeline confirming that tests have shown it is unlikely to burst in service. [Pg.481]

One curious observation, however, was that pure U actually had a lower radioactivity than natural U compounds. To investigate this. Curie synthesized one of these compounds from pure reagents and found that the synthetic compound had a lower radioactivity than the identical natural example. This led her to believe that there was an impurity in the natural compound which was more radioactive than U (Curie 1898). Since she had already tested all the other elements, this impurity seemed to be a new element. In fact, it turned out to be two new elements—polonium and radium— which the Curies were successfully able to isolate from pitchblende (Curie and Curie 1898 Curie et al. 1898). For radium, the presence of a new element was confirmed by the observation of new spectral lines not attributable to any other element. This caused a considerable stir and the curious new elements, together with their discoverers, achieved rapid public fame. The Curies were duly awarded the 1903 Nobel prize in Physics for studies into radiation phenomena, along with Becquerel for his discovery of spontaneous radioactivity. Marie Curie would, in 1911, also be awarded the Nobel prize in chemistry for her part in the discovery of Ra and Po. [Pg.663]

The homogeneity of the product should be addressed. The adequacy of mixing processes should be shown (and confirmed with appropriate process validation data) and potential segregation discussed (as affected by surface properties, crystallinity, particle size, etc.). The Ph Eur uniformity of content requirements should apply to the dosage forms and uniformity of distribution needs to be shown between batches and within batches. The need for appropriate routine tests as part of the release specification should be discussed. [Pg.653]

The computerized systems, both hardware and software, that form part of the GLP study should comply with the requirements of the principles of GLP. This relates to the development, validation, operation and maintenance of the system. Validation means that tests have been carried out to demonstrate that the system is fit for its intended purpose. Like any other validation, this will be the use of objective evidence to confirm that the pre-set requirements for the system have been met. There will be a number of different types of computer system, ranging from personal computers and programmable analytical instruments to a laboratory information management system (LIMS). The extent of validation depends on the impact the system has on product quality, safety and record integrity. A risk-based approach can be used to assess the extent of validation required, focusing effort on critical areas. A computerized analytical system in a QC laboratory requires full validation (equipment qualification) with clear boundaries set on its range of operation because this has a high... [Pg.222]

The informative SNPs could be tested prospectively through the surveillance network, and decreases in rate could be confirmed. If confirmed, the tests would be rapidly approved and implemented as part of the risk-reduction strategy for the marketed drug. [Pg.101]


See other pages where Confirmation Test.Part is mentioned: [Pg.9]    [Pg.825]    [Pg.825]    [Pg.503]    [Pg.245]    [Pg.31]    [Pg.472]    [Pg.720]    [Pg.218]    [Pg.148]    [Pg.41]    [Pg.110]    [Pg.117]    [Pg.839]    [Pg.94]    [Pg.154]    [Pg.364]    [Pg.180]    [Pg.137]    [Pg.1458]    [Pg.243]    [Pg.243]    [Pg.167]    [Pg.81]    [Pg.181]    [Pg.494]    [Pg.68]    [Pg.84]    [Pg.498]    [Pg.45]    [Pg.290]    [Pg.1508]    [Pg.406]   


SEARCH



CONFIRM

Confirmation

© 2024 chempedia.info