Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Computing using light beams

It is highly likely that by the second decade of the new millennium silicon-based computing will have reached fundamental technological or physical limits. Computers will therefore be based on substrates that exhibit superior performance characteristics. One possibility is the photon. Optoelectronic devices, which use substrates such as gallium arsenide, permit the interconversion of electrons and photons. Hybrid computers, which may already be available commercially by 2010, would use silicon for computation and photons for data transfer. The coherent modulation of very-high-frequency light beams enables many high-capacity... [Pg.167]

Plane waves have infinite lateral extent and, for this reason, cannot be simulated on a computer because of floating-point overflow. If the lateral extent is constrained, as in Problem 6.11 of Jackson [5], longitudinal solutions appear in the vacuum, even on the U(l) level without vacuum charges and currents. This property can be simulated on the computer using boundary conditions, for example, a cylindrical beam of light. It can be seen from a comparison of Eqs. (625) and (629) that if the Lorenz condition is not used, there is no increase... [Pg.199]

The interaction between the matter and the light beam is weak and I compute the state TOt using perturbation theory based on the complete set of exact states /> , with energies ha> of the chiral medium in the absence of the light beam, noting that the information yielded by the experiment can then be related to the optically active medium alone. The density matrix, , for the medium in the absence of the light beam can be given a spectral representation in terms of this complete set of states, by virtue of the spectral theorem,... [Pg.16]

Fig. 2. Automated torsion pendulum schematic. An analog electrical signal results from using a light beam passing through a pair of polarizers, one of which oscillates with the pendulum. The penduluin is aligned for linear response and initiated by a computer that also processes the damped waves to provide the elastic modulus and mechanical damping data, which are plotted vs. temperature or time... Fig. 2. Automated torsion pendulum schematic. An analog electrical signal results from using a light beam passing through a pair of polarizers, one of which oscillates with the pendulum. The penduluin is aligned for linear response and initiated by a computer that also processes the damped waves to provide the elastic modulus and mechanical damping data, which are plotted vs. temperature or time...
Fig. 2.17. Schematic layout of a microscope spectrophotometer system used to measure polarized absorption spectra of very small mineral crystals. The computer-operated, single-beam instrument shown here comprises a polarizing microscope equipped with a stabilized light source (xenon arc lamp or tungsten lamp cover the range 250-2000 nm), a modulator that chops the light beam with a frequency of 50 Hz (the amplifier for the photodetector signals is modulated with the same phase and frequency), and a Zeiss prism double monochromator. Single crystals as small as 10 ji.m diameter may be measured with this system. A diamond-windowed high-pressure cell can be readily mounted on the microscope scanning table for spectral measurements at very high pressures (after Burns, 1985, reproduced with the publisher s permission). Fig. 2.17. Schematic layout of a microscope spectrophotometer system used to measure polarized absorption spectra of very small mineral crystals. The computer-operated, single-beam instrument shown here comprises a polarizing microscope equipped with a stabilized light source (xenon arc lamp or tungsten lamp cover the range 250-2000 nm), a modulator that chops the light beam with a frequency of 50 Hz (the amplifier for the photodetector signals is modulated with the same phase and frequency), and a Zeiss prism double monochromator. Single crystals as small as 10 ji.m diameter may be measured with this system. A diamond-windowed high-pressure cell can be readily mounted on the microscope scanning table for spectral measurements at very high pressures (after Burns, 1985, reproduced with the publisher s permission).
In the photocentrifuge method the concentration of a suspension is monitored using a light beam. The light can come from either a white light source (an incandescent bulb) or a monochromatic coherent source (a laser) and the detector may be either a photodiode or photomultiplier. The signal from the detector is usually digitized and converted to a size distribution via a computer. [Pg.417]

The technique of flame atomic absorption spectrophotometry accomplishes this by aspirating the sample solution into a burner chamber, where it is mixed with a fuel gas and an oxidant gas. The mixture is then burned in a specially designed burner head (Fig. 2). The light beam is directed lengthway down the burner, and the absorption of the analyte atoms in the flame is measured. The most commonly used gas mixtures are air with acetylene and nitrous oxide with acetylene. Experimental conditions are well-defined in the literature, and cookbook conditions are available from most instrument manufacturers. In addition, many instruments are computer-controlled, and typical conditions are available directly on the operating screen. [Pg.3368]

Let us stress that the operational definition of the quantum phase of radiation [47] is also based on the use of bilinear forms in the photon operators. In the simplest form, the idea of the operational approach to the phase difference can be illustrated with the aid of the two-port interferometer shown in Fig. 11 (see Refs. 14 and 47 for more detailed discussion). The two incident monochromatic (or quasimonochromatic) light beams are combined by a symmetric beamsplitter oriented at 45° to each beam. The resultant intensities emerging from each output port are measured by the two photodetectors connected with a comparator (computer) as in the Hanbury-Brown-Twiss interferometer [85] (also see Refs. 14, 15, and 86). Following Noh et al. [47], we denote by a and 2 the photon annihilation operators, describing the field at the two input ports, and by a and 04 the corresponding operators at the two output ports. Then... [Pg.445]


See other pages where Computing using light beams is mentioned: [Pg.53]    [Pg.204]    [Pg.5]    [Pg.219]    [Pg.258]    [Pg.98]    [Pg.258]    [Pg.115]    [Pg.653]    [Pg.384]    [Pg.227]    [Pg.693]    [Pg.148]    [Pg.384]    [Pg.117]    [Pg.18]    [Pg.192]    [Pg.51]    [Pg.227]    [Pg.384]    [Pg.309]    [Pg.257]    [Pg.668]    [Pg.3446]    [Pg.211]    [Pg.314]    [Pg.131]    [Pg.113]    [Pg.476]    [Pg.607]    [Pg.619]    [Pg.2093]    [Pg.340]    [Pg.220]    [Pg.74]    [Pg.523]    [Pg.1076]    [Pg.1077]    [Pg.227]    [Pg.294]    [Pg.458]    [Pg.3]   
See also in sourсe #XX -- [ Pg.167 ]




SEARCH



Computer use

Light beam

© 2024 chempedia.info