Compressor-condensate

In oil lubricated compressors a condensate is formed [18]. Such condensate is an oil in water emulsion with typical oil contents of 0.5%. In various countries discharge of more than 10 ppm oil is prohibited, e.g. in Austria since the beginning of 1992. In Germany, for new investments for waste water cleaning, the use of chemicals to break emulsions is forbidden. Furthermore, incineration of oily waste streams requires the highest oil content possible. [Pg.620]

With ceramic membranes (typical pore size 0.2 pm) this legal limit of 10 ppm is easily obtained [18]. Average membrane flux is 150 1/m h values are reported between 125 and 6001/m h [19]. The interval between cleanings or the maintenance interval can amount to 1000 h. By combination of the membrane unit with a static separator the concentration factor can be as high as 180, the oil content in the final concentrate can amount to over 90%. The pay-back time for such an installation would be less than two years at a cost of NLG 94/m effluent, and related to the present costs of treatment [18]. [Pg.621]


FIG. 11-98 Performance of complete refrigeration system (1), when there is reduction in heat load (2), and when for the same ambient (or inlet in evaporator) evaporation temperature is maintained constant hy reducing capacity of compressor/condenser part (3). [Pg.1117]

In air conditioning circles, the tower normally represents the final heat sink in a turnkey package which would include compressors/condensers, pipework, ducting, fans, pumps, control gear, etc. Where consultants and experienced contractors are concerned, the tower specification is well defined and the purchases based upon economics related to efficiency. [Pg.528]

Figure 8.24. Simpler circuits of compression refrigeration (see also Example 8.17). (a) Basic circuit consisting of a compressor, condenser, expansion valve and evaporator (load), (b) Conditions of the basic circuit as they appear on a pressure-enthalpy diagram the primed points are on the vapor-liquid boundary curve, (c) Circuit with circulation of refrigerated brine to process loads, (d) Circuit with two-stage compression and intercooling. Figure 8.24. Simpler circuits of compression refrigeration (see also Example 8.17). (a) Basic circuit consisting of a compressor, condenser, expansion valve and evaporator (load), (b) Conditions of the basic circuit as they appear on a pressure-enthalpy diagram the primed points are on the vapor-liquid boundary curve, (c) Circuit with circulation of refrigerated brine to process loads, (d) Circuit with two-stage compression and intercooling.
Fig. 2.57. Laboratory freeze-drying plant. Microprocessor controlled, air-cooled compressor, condenser end temperature-53 °C, 3 kg of ice sublimed in 24 h. (a) Unit with 8 valve connections for 8 containers, condenser in an... Fig. 2.57. Laboratory freeze-drying plant. Microprocessor controlled, air-cooled compressor, condenser end temperature-53 °C, 3 kg of ice sublimed in 24 h. (a) Unit with 8 valve connections for 8 containers, condenser in an...
Design of the evaporator, compressor, condenser, and auxiliary equipment requires knowledge of the rate of circulation of refrigerant m. This is determined from the heat absorbed in the evaporatorf by the equation ... [Pg.149]

Computer simulation models have been formulated for cascade and Stratco sulfuric acid alkylation units. These complete models incorporate mathematical descriptions of all the interacting parts of the units, including reactors, distillation columns, compressors, condensers, and heat exchangers. Examples illus-strate diverse model applications. These Include identifying profitable unit modifications, comparing cascade to Stratco performance, evaluating optimal unit capacity and determining optimal deisobutanizer operation. [Pg.270]

Fig. 1.17. Schematic diagram of a continuous cold stabilization system 1, intake of wine to be treated 2, heat exchanger 3, refrigeration system (with compressor, condenser, etc.) 4, insulation 5, mechanical agitator 6, recycling circuit (optional) 7, outlet of treated wine 8, filter (earth) 9, drain 10, overflow... Fig. 1.17. Schematic diagram of a continuous cold stabilization system 1, intake of wine to be treated 2, heat exchanger 3, refrigeration system (with compressor, condenser, etc.) 4, insulation 5, mechanical agitator 6, recycling circuit (optional) 7, outlet of treated wine 8, filter (earth) 9, drain 10, overflow...
PACKAGE UNITS, (REFRIGERATION) - Complete refrigerating system including compressor, condenser and evaporator located in the refrigerated space. [Pg.112]

Split System Air Conditioner - An air conditioning system that comes in two to five pieces one piece contains the compressor, condenser, and a fan the others have an evaporator and a fan. The condenser, installed outside the house, connects to several evaporators, one in each room to be cooled, mounted Inside the house. Each evaporator is individually controlled, allowing different rooms or zones to be cooled to varying degrees. [Pg.416]

An ordinary fluidized bed drying system consists of a blower, heater, dehumidifler (optional), fluidized bedchamber, and cyclone, whereas an ordinary heat pump drying system consists of evaporator, compressor, condenser, and an expansion valve. By combining fluidized bed and heat pump drying systems, where the evaporator acts as a dehumidifler and the condenser as a heater, a heat pump FBD is formed. [Pg.179]

It should be mentioned that the application of this modular design is not exhaustive, it extends beyond drying and cold storage applications. The concept of a coupled and decoupled process, for easy interface between equipment and air-handling unit, can be used in many air-conditioning applications through appropriate selection of expansion valve, compressor, condensers, evaporators, and refrigerant. [Pg.1122]

Sulfur Dioxide - 60 16 — E plus S7O in compressor condensate for alkylation unit. Alloy C = 0 03 mpy with less thM 1.0 ml pitting. [Pg.712]

Membrane life is an important factor affecting process economics. Membranes typically require replacement every three to seven years. It is therefore necessary to consider factors that may shorten or possibly extend their life. Funk et al. (1986) investigated the effect of impurities in the gas on a cellulose acetate membrane in acid gas service. They found that various components in the gas affect the permeability, the tensile strength, and the elastic modulus of the membrane. Some of the adverse effects of individual components can be mitigated by proper design (e.g., temperature control), but other impurities may require removal prior to membrane processing. Therefore, the feed gas should be evaluated for the presence of particulates, entrained liquids, oil mist (compressors), condensible components, all trace compounds, and water. Pretreatment systems that may be needed include ... [Pg.1246]

On September 15, several key systems were resampled in addition to several air compressor condensate lines and pre- and post-chlorination river water. Raw river water had a fairly modest count (1,500/ml) with a wide variety of species. Post-chlorinated water was collected in thiosulfate to neutralize the residual chlorine. The results suggest that short-term contact (seconds) had no effect on the total count (1,200/ml), although only two species were detected in this sample. A sample of service water was collected from the main header at a point most distal (south) from the intake source. The count was reduced to 21/ml. All the service water systems except one exhibited extremely... [Pg.258]

Ceramic microfiltration is another technology that is being applied in solvent and water-based paint production, and paint applying, industries for the treatment of paint-water mixtures, plus other areas such as oil-water emulsions, compressor condensate and degreasing baths. [Pg.266]


See other pages where Compressor-condensate is mentioned: [Pg.478]    [Pg.996]    [Pg.308]    [Pg.328]    [Pg.70]    [Pg.149]    [Pg.62]    [Pg.149]    [Pg.200]    [Pg.283]    [Pg.620]    [Pg.41]    [Pg.391]    [Pg.250]    [Pg.382]   