Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Composition-averaged parameter

Au-Cu and Au-Ag alloys Isomer shift and electrical resistivity as function of alloy composition and, in CU3AU, of pressure model to describe 5 in terms of average atomic volume, of short-range parameter and alloy composition average charge density on Au... [Pg.370]

The transport parameters and the specific heat of the system are considered to be independent of temperature and composition. Average values are used for these parameters and the ratio of Schmidt to Prandtl number is taken as unity throughout the system. [Pg.118]

As can be seen, the interaction energy is supposed to be of the same form as in Eq. (7), however, the scale factors and are now average composition-dependent parameters. Moreover, for blends based on random copolymers the quantities e a, r A et cetera of the right-hand side of Eq. (8) also have to be replaced by average parameters , and so on. The latter mean values are now number averages over the copolymer composition in terms of mole fractions. [Pg.36]

The MS data are quantitated with the aid of proprietary computer programs. These include programs that calculate composite values from the MS composition for average parameters typically determined by NMR, such as fraction of carbons in aromatic structures and angular H atoms. The scope of these programs is still increasing. [Pg.238]

Consider now the lattices diagrammed in Figures 4.6 and 4.7. Whereas the N dependence of (n) will be found to be qualitatively correct, the fact that these finite lattices are not characterized by a uniform valency v limits the usefulness of Eq. (4.21). In fact, it is necessary to introduce composite (average) lattice parameters in order to be able to compare trends in the data. Specifically, one parameter is needed to account for the nonuniform valency and one parameter to reflect and/or characterize the variety of geometrical shapes. Consistent with the identification of an overall (average) walklength... [Pg.267]

Assuming random mixing, Jain and Simha [1980,1984] have shown that in binary systems, Eqs. (14.2) and (14.3) retain validity, but the L-J parameters s and v are compositional averages of 11,22, and 12 interactions ... [Pg.557]

The CCD curve shown in Fig. 15 contains all the information on composition distribution and it is a common practice to compare the CCD curves of the different resins to be evaluated In addition to the CCD curve, it is convenient to work with some easy-to-use average parameters. In the case of multiple peaks (like those shown in Fig. 15), integration of the peaks is most appropriate. In bimodal LLDPE, the most important parameters to measure are the homopolymer (linear) and soluble fraction percentages. Calculation of moments similar to... [Pg.226]

The growth of scale thicknesses, Xg, under these conditions increases as the square root of time. Values of the composition-average diffusion coefficients are calculated from the equation DM(ThN) = Xs /4 tu where the parameter u is the solution to the equation AX(ThN)/ AX(l,ThN) = jtu e erf u, where AX(ThN) is the drop in N concentration across the ThN layer and AX(l,ThN) is the drop in N concentration at the inside interface between Th-saturated ThN and N-saturated liquid Th as calculated from the phase diagram. The Dfg(ThN) values at temperatures of 1900 to 2400°C are illustrated in Fig. 1, p. 4, and show a possible downward curvature at the more elevated temperatures in the In Dn-vs.-1/T plot. Disregarding the possible curvature and assuming a straight line, the data are represented by the equation... [Pg.24]

When applied to partide-reinforced polymer composites, micromechanics models usually follow certain basic assumptions linear elasticity of fillers and polymer matrix the fillers are axisymmetric, identical in shape and size, and can be characterized by parameters such as aspect ratio well-bonded filler-polymer interface, so no interfacial slip is considered filler-matrix debonding and matrix microcraddng. Further details of some important preliminary concepts such as hnear elastidty, average stress and strain, composites average properties, and the strain concentration and stress concentration tensors can be found in preview literature [48-50]. [Pg.122]

The results presented below were obtained using a 2 mm thick carbon fiber reinforced epoxy composite laminate with 16 layers. The laminate was quasi isotropic with fiber orientations 0°, 90° and 45°. The laminate had an average porosity content of approximately 1.7%. The object was divided in a training area and an evaluation area. The model parameters were determined by data solely from the training area. Both ultrasound tranducers used in the experiment had a center frequency of 21 MHz and a 6 dB bandwidth of 70%. [Pg.890]

Constant volume heat capacities for Hquid organic compounds were estimated with a four parameter fit (219). A 1.3% average absolute error for 31 selected species was reported. A group contribution method for heat capacities of pure soHds andHquids based on elemental composition has also been provided (159). [Pg.253]

In a permeation experiment, an HERO module with a membrane area of 200 m is used to remove a nickel salt from an electroplating wastewater. TTie feed to the module has a flowrate of 5 x IQ— m /s, a nickel-salt composition of 4,(X)0 ppm and an osmotic pressure of 2.5 atm. The average pressure difference across the membrane is 28 atm. The permeate is collected at atmospheric pressure. The results of the experiment indicate that the water recovery is 80% while the solute rejection is 95%. Evaluate the transport parameters Ay and (D2u/KS). [Pg.271]

The lattice parameters showed considerable variation from one crystal to another with average values a 875 pm, c 506 pm this is now thought to arise from variable composition depending on the precise preparative conditions used. [Pg.143]

The reliability factor B was 0276 after the first refinement and 0-211 after the fourth refinement. The parameters from the third and fourth refinements differed very little from one another. The final values are given in Table 1. As large systematic errors were introduced in the refinement process by the unavoidable use of very poor atomic form factors, the probable errors in the parameters as obtained in the refinement were considered to be of questionable significance. For this reason they are not given in the table. The average error was, however, estimated to be 0-001 for the positional parameters and 5% for the compositional parameters. The scattering power of the two atoms of type A was given by the least-squares refinement as only 0-8 times that of aluminum (the fraction... [Pg.608]

Despite the difficulties, there have been many efforts in recent years to evaluate trace metal concentrations in natural systems and to compare trace metal release and transport rates from natural and anthropogenic sources. There is no single parameter that can summarize such comparisons. Frequently, a comparison is made between the composition of atmospheric particles and that of average crustal material to indicate whether certain elements are enriched in the atmospheric particulates. If so, some explanation is sought for the enrichment. Usually, the contribution of seaspray to the enrichment is estimated, and any enrichment unaccounted for is attributed to other natural inputs (volcanoes, low-temperature volatilization processes, etc.) or anthropogenic sources. [Pg.379]

The Eo values for 2-substituted 1,4-benzoquinones (sets 45-4 through 45-7, 45-10) show an average value of pr of 59. Thus the resonance effect predominates. For most of these sets, the Op constants are not the best parameters for correlation. By contrast, the electron reduction potentials (set 45-8) show a Pr value of 39, which indicates predominance of the localized effect. The 2,5-disubstituted 1,4-benzoquinones differ distinctly in their behavior from the 2-substituted 1,4-benzoquinones in that they show an average Pr value of 53. The one-electron reduction potentials of these compounds show about the same composition of the electrical effect, with a value of Pr of 50. The only set of Eq values available for the 2,6-disubstituted 1,4-benzoquinones pve a Pr value of 51, comparable to the values observed for the 2,5-disubsti-tuted 1,4-benzoquinones. The 2,3,5,6-tetrasubstituted 1,4-benzoquinones have... [Pg.167]


See other pages where Composition-averaged parameter is mentioned: [Pg.382]    [Pg.382]    [Pg.1243]    [Pg.30]    [Pg.502]    [Pg.967]    [Pg.29]    [Pg.78]    [Pg.810]    [Pg.221]    [Pg.212]    [Pg.72]    [Pg.235]    [Pg.51]    [Pg.157]    [Pg.40]    [Pg.454]    [Pg.430]    [Pg.396]    [Pg.520]    [Pg.242]    [Pg.502]    [Pg.252]    [Pg.1254]    [Pg.700]    [Pg.344]    [Pg.468]    [Pg.138]    [Pg.306]    [Pg.172]    [Pg.297]    [Pg.32]    [Pg.410]    [Pg.466]   


SEARCH



Average comonomer composition parameters

Composite parameters

Composition-averaged parameter evaluation

© 2024 chempedia.info