Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Composite Correction Program

The CPE/CCP approach to POTW evaluation proceeds in two distinct but linked phases. The Comprehensive Performance Evaluation identifies and prioritizes the design, operational, maintenance, and administrative factors which may be the cause(s) of suboptimal POTW performance. The Composite Correction Program implements procedures (e.g., changes in plant operations, training for plant operators) to address these factors. The CPE and CCP are linked in that implementation of the CCP may feed back to affect the content or order of the prioritized list of factors affecting plant performance. The distinction between CPE and CCP marks a logical problem boundary for an expert system built around the CPE/CCP approach development of POTW EXPERT to date has focused on the Comprehensive Performance Evaluation. [Pg.127]

A new value of frequency is specified and the calculations repeated. Table 12.3 gives a FORTRAN program that performs alt these calculations, The initial part of the program solves for all the steadystate compositions and flow rates, given feed composition and feed flow rate and the desired bottoms and distillate compositions, by converging on the correct value of vapor boilup Vg. Next the coeflicients for the linearized equations arc calculated. Then the stepping technique is used to calculate the intermediate g s and the final P(j transfer functions in the frequency domain. [Pg.446]

Fundamental Parameters (FP) are universal standardless, factory built-in calibration programs that describe the physics of the detector s response to pure elements, correction factors for overlapping peaks, and a number of other parameters to estimate element concentration while theoretically correcting for matrix discrepancies (e.g., Figure 1987). FP should be used for accurately measuring samples of unknown chemical composition in which concentrations of light and heavy elements may vary from ppm to high percent levels. [Pg.84]

These were calculated from the analytical solution compositions given in Table III using the computer program MINEQL (Westall, Zachary and Morel (17)) with stability constants selected from Kartell and Smith (18). MINEQL corrects for all hydrolysis and complexation and for computed ionic strength. The resulting values of KgQ are listed in Table III. The solubility data reported by Cameron (15) were rejected because our calculations showed his solutions to be much oversaturated with respect to HgO. [Pg.345]

Samples spiked with known amounts of stable isotopes Fe> Cu, Zn, Zn were prepared and the measured ion intensities in the mass spectra were compared to theoretical values The response of the mass spectrometer was linear over a wide range of enrichment levels ( ) A computer program included in the mass spectrometer software package was used to calculate the theoretical values for peak intensities in the mass spectra Corrections for isotopic composition of the ligand ( C, H) were made as described previously (2) ... [Pg.142]

Columns between Ke and y(H2) may contain intermediate quantities in the calculation of yni First test your program for the conditions of part (a) and verify that it is correct. Then try a variety of values of the input variables and draw conclusions about the conditions (reactor temperature and feed composition) that maximize the equilibrium yield of hydrogen. [Pg.173]

Using mass spectrometry techniques, the mass distribution of peptide mixtures can be experimentally determined and compared to the theoretical mass distribution this distribution has the shape of a beU curve, and can be calculated using various computer programs. These data provide important information on the composition of the analyzed peptide mixture. While it is not possible to verify the correct representation of each individual peptide within the nnixture, the mass distribution curve can be used to confirm the correct overall composition of the nnixture. It is also often possible to confirm the correct amino acid at a defined position of a peptide nnixture. For example, the average mass (i.e., the peak of the mass distribution bell curve) of the mixture AC-AXXXXX-NH2 (716) is sufficiently different from that of the mixture AC-YXXXXX-NH2 (808). Furthermore, an incorrect mass distribution of the peptide nnixture can indicate problems that occurred during the synthesis, such as incomplete side-chain deprotection of a particular annino acid. [Pg.858]


See other pages where Composite Correction Program is mentioned: [Pg.127]    [Pg.127]    [Pg.92]    [Pg.94]    [Pg.346]    [Pg.163]    [Pg.461]    [Pg.386]    [Pg.139]    [Pg.286]    [Pg.93]    [Pg.202]    [Pg.253]    [Pg.87]    [Pg.166]    [Pg.431]    [Pg.126]    [Pg.103]    [Pg.67]    [Pg.129]    [Pg.297]    [Pg.122]    [Pg.126]    [Pg.85]    [Pg.285]    [Pg.106]    [Pg.266]    [Pg.244]    [Pg.168]    [Pg.493]    [Pg.359]    [Pg.207]    [Pg.208]    [Pg.213]    [Pg.2509]    [Pg.29]    [Pg.87]    [Pg.313]    [Pg.429]    [Pg.625]    [Pg.207]    [Pg.385]    [Pg.262]   


SEARCH



© 2024 chempedia.info