Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Complexing potentiometry

In all cases, potentiometric titrations provide important constraints on the metalspeciation in aqueous fluids. Although it cannot provide the structure of the complexes, potentiometry constrains the stoichiometries of the possible complexes, and changes with metal concentration, ligand concentration, and pH. [Pg.169]

The potentiometry sensor (ion-selective electrode) controls application for determination of polymeric surface-active substances now gets the increasing value. Potentiometry sensor controls are actively used due to simple instmment registration, a wide range of determined concentrations, and opportunity of continuous substances contents definition. That less, the ionometry application for the cation polymeric SAS analysis in a solution is limited by complexity of polycation charge determination and ion-exchanger synthesis. [Pg.108]

In addition we studied the complexation of ClC+ by the polyamines using microcalorimetry and potentiometry. The enthalpy changes measured are presented as function of the degree of protonation and the amount of CiT bound. [Pg.148]

Potentiometry (discussed in Chapter 5), which is of great practical importance, is a static (zero current) technique in which the information about the sample composition is obtained from measurement of the potential established across a membrane. Different types of membrane materials, possessing different ion-recognition processes, have been developed to impart high selectivity. The resulting potentiometric probes have thus been widely used for several decades for direct monitoring of ionic species such as protons or calcium, fluoride, and potassium ions in complex samples. [Pg.2]

Many IC techniques are now available using single column or dual-column systems with various detection modes. Detection methods in IC are subdivided as follows [838] (i) electrochemical (conductometry, amper-ometry or potentiometry) (ii) spectroscopic (tJV/VIS, RI, AAS, AES, ICP) (iii) mass spectrometric and (iv) postcolumn reaction detection (AFS, CL). The mainstay of routine IC is still the nonspecific conductometric detector. A significant disadvantage of suppressed conductivity detection is the fact that weak to very weak acid anions (e.g. silicate, cyanide) yield poor sensitivity. IC combined with potentiometric detection techniques using ISEs allows quantification of selected analytes even in complex matrices. The main drawback... [Pg.271]

Applications Potentiometry finds widespread use for direct and selective measurement of analyte concentrations, mainly in routine analyses, and for endpoint determinations of titrations. Direct potentiometric measurements provide a rapid and convenient method for determining the activity of a variety of cations and anions. The most frequently determined ion in water is the hydrogen ion (pH measurement). Ion chromatography combined with potentiometric detection techniques using ISEs allows the selective quantification of selected analytes, even in complex matrices. The sensitivity of the electrodes allows sub-ppm concentrations to be measured. [Pg.669]

The complexation of other mixed oxa aza macrocycles has been studied, and protonation and stability constants of the zinc complexes of macrocycles l,4,10,13-tetraoxa-7,16-diazacycloocta-decane-7,16-bis(malonate), the -7-malonate derivative and -7,16-bis(methylacetate) derivative have been determined by potentiometry at a 1 1 ligand-to-metal ratio.730... [Pg.1211]

Classical methods for the investigation of complex formation equilibria in solution (UV/Vis spectrometry, thermochemical and electrochemical techniques) are still in use (for an appraisal of these and other methods see, e.g., ref. 22). Examples for the determination of the ratio of metal to ligand in an Hg-protein complex by UV spectrometry are given in ref. 23, for the study of distributions of complex species of Cd in equilibria by combined UV spectrometry and potentio-metry in ref. 24 and by potentiometry alone in ref. 25, and for the combination of calorimetry and potentiometry to obtain thermodynamic data in ref. 26. [Pg.1254]

Complexation of Cd with a series of polyamine macrocycles, but also related open-chain polyamines, comprising or attached to the 2,2 -bipyridine (bipy) and 1,10-phenanthroline (phen) moieties, has been studied by combined UV/vis spectrometry and potentiometry.24 Formation constants and distribution diagrams of the species present have been evaluated. As a result the thermodynamic stabilities, i.e., the formation constants, are lower for the bipy- and phen-contain-ing ligands than those for Cd complexes with aliphatic oligoaza macrocycles containing the same number of N donors. The probable reason is loss of flexibility of the ligands caused by the size and stiffness of the inserted heteroaromatic moieties. [Pg.1270]

Stepwise formation constants have been determined in the system Hg2+/Cl-/diethylenetriamine (dien) and related systems by potentiometry. Thermodynamic parameters have been calculated and the contribution of the entropy term to complex stability discussed.208... [Pg.1273]

Sodium valproate has been determined in pharmaceuticals using a valproate selective electrode [13,14]. The electroactive material was a valproate-methyl-tris (tetra-decyl)ammonium ion-pair complex in decanol. Silver-silver chloride electrode was used as the reference electrode. The electrode life span was >1 month. Determination of 90-1500 pg/mL in aqueous solution by direct potentiometry gave an average recovery of 100.0% and a response time of 1 min. [Pg.228]

The selectivity here is directly proportional to complex formation constants and can be estimated, once the latter are known. Several methods are now available for determination of the complex formation constants and stoichiometry factors in solvent polymeric membranes, and probably the most elegant one is the so-called sandwich membrane method [31], Two membrane segments of different known compositions are placed into contact, which leads to a concentration polarized sensing membrane, which is measured by means of potentiometry. The power of this method is not limited to complex formation studies, but also allows one to quantify ion pairing, diffusion, and coextraction processes as well as estimation of ionic membrane impurity concentrations. [Pg.106]

In order to determine the stability constants for a series of complexes in solution, we must determine the concentrations of several species. Moreover, we must then solve a rather complex set of equations to evaluate the stability constants. There are several experimental techniques that are frequently employed for determining the concentrations of the complexes. For example, spectrophotometry, polarography, solubility measurements, or potentiometry may be used, but the choice of experimental method is based on the nature of the complexes being studied. Basically, however, we proceed as follows. A parameter is defined as the average number of bound ligands per metal ion, N, which is expressed as... [Pg.677]

Brugmann [784] discussed different approaches to trace metal speciation (bioassays, computer modelling, analytical methods). The electrochemical techniques include conventional polarography, ASV, and potentiometry. ASV diagnosis of seawater was useful for investigating the properties of metal complexes in seawater. Differences in the lead and copper values yielded for Baltic seawater by methods based on differential pulse ASV or AAS are discussed with respect to speciation. [Pg.269]

Complexes of beryllium with phosphonate ligands have been extensively researched, mainly by potentiometry. The ligands investigated are as follows methylphosphonate (259, 260) chloromethyl-phosphonate (259) 2-aminopropane-l-phosphonate (259) methylene-diphosphonate (130, 260, 261) hexamethylenediphosphonate (259) l-hydroxyethane-l,l-diphosphonate (261) 1,1-dimethyl-1-amino-... [Pg.157]

An appropriate ion-specific electrode was found to provide a convenient, precise and relatively inexpensive method for potentiometry of copper(II) ion in copper-complex azo or formazan dyes. Copper(II) ion in copper phthalocyanine dyes can be quantified after anion exchange. Twelve commercial premetallised dyes evaluated using this technique contained copper(II) ion concentrations in the range 0.007 to 0.2%. Thus many copper-complex direct or reactive dyes are likely to contribute low but possibly significant amounts of ionic copper to textile dyeing effluents [52]. [Pg.265]

Saar and Weber [1] compared methods based on spectrofluorimetry and ion-selective electrode potentiometry for determining the complexes formed between fulvic acid and heavy metal ions. [Pg.282]

Analytical determinations with the fluoride ion-selective electrode These are based either on direct potentiometry of fluorides [37, 84, 85, 88, 430] or on titration determinations of either fluorides or of other ions and also on titrations with fluoride ions as indicator. The advantages of potentiometry with an ISE over other analytical methods for determining fluorides were pointed out by Crosby etai [67], Further comparison studies [42, 56, 191, 433] came to the same conclusions, confirmed also by a study of 16 methods [365]. Fluoride ions are titrated either with La (for concentrations greater than 1 mM) or Th (in the concentration range 0.2-1 mM F ) [13, 102, 103, 113,233, 234]. Titration with fluoride ions can be used for the determination of Al with formation of the AIF4 complex up to nanomolar concentrations, especially in ethanol-water mixtures [25] (see also [267,384]). Precipitation titrations can also be used to determine La, Th and UOJ [241, 384] as well as Li in... [Pg.153]

In this work, we have chosen several systems stabilized through hydrogen bonds. The homopolymer is a polybase, i.e. PEO, PVME or PVP, and the copolymer is polyacrylic acid with various degrees of neutralization a, in which the acrylates are the non active groups. Complex formation is studied by potentiometry (because complexation induces a variation of the solution pH) and by viscometry and polarized luminescence which respectively give information about the macroscopic and local structure of the complex in solution. The influence of parameters such as the degree of neutralization of PAA a, the concentration ratio r - [polybase]/[PAA], the concentration and the molecular weight of polymers is examined. [Pg.73]

From potentiometry results we can easily calculate the degree of complexation, which is the ratio of the concentration of complexed acid groups to the total concentration of PAA 0 =... [Pg.75]

When a validated hit is selected as a promising lead compound, its physicochemical profile must be studied in detail. Sophisticated in silica approaches such as 3D lipophilicity predictions coupled with extensive conformational analysis [49, 50,135,146] and molecular field interactions (MIFs) [147-150] could be helpful to better interpret the detailed experimental investigations of their ionization constants by capillary electrophoresis or potentiometric titrations [151, 152] and their lipophilicity profiles by potentiometry [153]. However, these complex approaches cannot be performed easily on large number of compounds and are generally applied only on the most promising compounds. [Pg.107]

Over the past decades several techniques have been used to obtain direct experimental information on the speciation of peroxo metal complexes heteronuclear NMR, IR and Raman spectroscopy, potentiometry and electrospray ionization mass spectrometry (ESI-MS). Often, more than one technique was used at the same time for acquiring complementary evidence. A significant, although nonexhaustive, list of examples related to several metals is given in Table 2. They include cases with hydrogen peroxide or alkyl... [Pg.1069]


See other pages where Complexing potentiometry is mentioned: [Pg.92]    [Pg.92]    [Pg.454]    [Pg.406]    [Pg.92]    [Pg.92]    [Pg.454]    [Pg.406]    [Pg.1023]    [Pg.16]    [Pg.251]    [Pg.272]    [Pg.64]    [Pg.331]    [Pg.115]    [Pg.29]    [Pg.114]    [Pg.1153]    [Pg.1204]    [Pg.1207]    [Pg.1210]    [Pg.1273]    [Pg.93]    [Pg.123]    [Pg.644]    [Pg.282]    [Pg.244]    [Pg.246]    [Pg.86]   
See also in sourсe #XX -- [ Pg.975 ]




SEARCH



Potentiometry

© 2024 chempedia.info