Soft tissue Spiked sample wet ashed, treated with HN03/H202, purified by A-CU column, anion exchange, TRU-spec column, and electrodeposition a -Spectrometry No data 53% Qu et al. 1998... [Pg.201]

Rat serum and plasma membrane proteins Design of the monolith cartridge, purification, comparison with conventional columns Anion Exchange, Affinity (Heparin) [45]... [Pg.75]

GTP gamma S binding proteins from membranes of porcine brain Purification, comparison with conventional column Anion Exchange and Affinity (Melittin) disks [82]... [Pg.76]

Model proteins Comparison of the separation on SMC (CIM ), UNO, Mono Q and Sartobind columns Anion Exchange disks [92]... [Pg.76]

Ion Exchange Chromatography—Separation mode for ionized compounds on charged columns. Anion-exchange columns attract and separate anions cation-exchange columns separate cations. [Pg.216]

Aggett and Kadwani [13] employed a two stage single column anion exchange method using sodium hydrogen carbonate and chloride as eluate anions. These species appear to have no adverse effects in subsequent analytical procedures. Its successful application is dependent on careful control of pH. Analyses were performed by hydride generation atomic absorption spectroscopy... [Pg.215]

Apply the sample to the column (anion exchange columns, e.g., DEAE Sepharose CL-6B) and elute with phosphate buffer. Collect 2-mL fractions and monitor the absorbance at 280 nm (Ajgo)... [Pg.86]

Cs is collected from larger volumes of water on large cation-exchange resin columns. Anion-exchange resin columns loaded with one of the above-cited precipitation reagents make these columns specific for cesium. A column loaded with... [Pg.108]

Amide herbicides - preconcentration using SPMDs then bioassay. (2) Diethanol amides by solid-phase extraction-liquid chromatography-atmospheric pressure chemical ionization/electrospray ionization mass spectrometry (SPE-LC-APCI/ESI-MS) o-Phthaldialdehyde derivatization then reversed-phase LC with fluorescence defecfion. Chiral derivafizafion permifs separation of optical isomers on standard LC columns Anion exchange LC Ion-pair liquid chromatography... [Pg.5021]

Two-dimensional LC to determine anionic surfactants (types of carboxylates, sulfates and sulfonates), cationic surfactants (quaternary ammonium and alkyl pyridinium salts) and amphoteric surfactants (amidobetaines) was proposed by Noguchi et al. (1998). First column (anion exchange column for anionics and cation exchange column for cationic and amphoteric surfactants) separated according to functional group and a second column (octadecylsilica) allowed the separation of alkyl homologues. The method was applied to shampoo. [Pg.307]

Fig. 5. Anion-exchange separation of insulin and insulin A- and B-chains, over diethylaminoethyl (DEAF) in a 10.9 x 200 mm column having a volume of 18.7 mL. Sample volume is 0.5 mL and protein concentration ia 16.7 mAf Tris buffer at pH 7.3 is 1 mg/mL for each component ia the presence of EDTA. Eluent (also 16.7 mAf Tris buffer, pH 7.3) flow rate is 1.27 ml,/min, and protein detection is by uv absorbance at 280 nm. The straight line depicts the salt... Fig. 5. Anion-exchange separation of insulin and insulin A- and B-chains, over diethylaminoethyl (DEAF) in a 10.9 x 200 mm column having a volume of 18.7 mL. Sample volume is 0.5 mL and protein concentration ia 16.7 mAf Tris buffer at pH 7.3 is 1 mg/mL for each component ia the presence of EDTA. Eluent (also 16.7 mAf Tris buffer, pH 7.3) flow rate is 1.27 ml,/min, and protein detection is by uv absorbance at 280 nm. The straight line depicts the salt...
Ton-exchange systems vary from simple one-column units, as used in water softening, to numerous arrays of cation and anion exchangers which are dependent upon the appHcation, quaHty of effluent required, and design parameters. An Hlustration of some of these systems, as used in the production of deionized (demineralized) water, is presented in Figure 7. [Pg.381]

Hplc techniques are used to routinely separate and quantify less volatile compounds. The hplc columns used to affect this separation are selected based on the constituents of interest. They are typically reverse phase or anion exchange in nature. The constituents routinely assayed in this type of analysis are those high in molecular weight or low in volatility. Specific compounds of interest include wood sugars, vanillin, and tannin complexes. The most common types of hplc detectors employed in the analysis of distilled spirits are the refractive index detector and the ultraviolet detector. Additionally, the recent introduction of the photodiode array detector is making a significant impact in the analysis of distilled spirits. [Pg.89]


See other pages where Columns anion-exchange is mentioned: [Pg.279]    [Pg.76]    [Pg.126]    [Pg.6096]    [Pg.223]    [Pg.221]    [Pg.127]    [Pg.268]    [Pg.279]    [Pg.6095]    [Pg.311]    [Pg.76]    [Pg.279]    [Pg.76]    [Pg.126]    [Pg.6096]    [Pg.223]    [Pg.221]    [Pg.127]    [Pg.268]    [Pg.279]    [Pg.6095]    [Pg.311]    [Pg.76]    [Pg.275]    [Pg.1114]    [Pg.593]    [Pg.45]    [Pg.48]    [Pg.52]    [Pg.197]    [Pg.478]    [Pg.523]    [Pg.363]    [Pg.377]    [Pg.380]    [Pg.380]    [Pg.382]    [Pg.382]    [Pg.384]    [Pg.386]    [Pg.387]    [Pg.25]    [Pg.11]    [Pg.51]    [Pg.244]    [Pg.41]    [Pg.62]   
See also in sourсe #XX -- [ Pg.74 ]




SEARCH



Anion exchange

Anion exchange columns latex coated

Anion exchanger

Anion-exchange columns Alltech

Anion-exchange columns Dionex

Anion-exchange columns Hamilton

Anion-exchange columns Metrohm

Anion-exchange, chloride column

Anion-exchange, chloride column resin

Anionic exchange

Anionic exchangers

Anions anion exchange

Exchange columns

Exchanger column

© 2024 chempedia.info