Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Anion-exchange columns Alltech

Thirteen different enantiomers were tentatively used to obtain a significant number of A-V chiral solute descriptors. They were selected because they were well resolved on the four Chirobiotic columns. The set contained eight ionic or zwit-terionic amino acids or amino acid derivatives and five molecular solutes. The 13 enantiomers were separated on 5 well-characterized achiral columns, namely a classical polymeric C18, a diphenyl bonded column, a weak anion exchanger (Primesep D, SiELC), a divinyl benzene bonded column, and a strong anion exchanger (SAX, Alltech). Five different ethanol-water mobile phases were used making more than 300 chromatograms to develop and to analyze. [Pg.26]

Crosslinked amine/Kel-F 800 silica (not commercially available), 4.6 X 250 mm Alltech Cjj HAE weak anion exchange column, 4.6 x 150 mm, or Alltech mixed-mode RP C4, RP Cg, or RP Phenyl ion exchange columns, 4,6 x 250 mm (RP Phenyl ion exchange preferred)... [Pg.248]

A HEMA-based anion exchanger developed by Alltech has been described as a universal stationary phase for the separation of a wide variety of anions [6,7]. This anion-exchange resin has been compared to agglomerated peUicular anion exchangers for the separation of anions by chemically suppressed 1C. The HEMA-based columns exhibit higher capacities for all anions and particularly for weakly retained anions such as fluoride and formate, which were completely resolved. The HEMA columns could be used for both isocratic and gradient techniques. [Pg.40]

Chemical and Agrochemical Applications Mohsin [263] developed an IC-MS method using thermospray and electrospray interfaces for the analysis of organophosphorus and organosulfur compounds in an insecticide such as monomethyl phosphate, monomethyl sulfate, and dimethyl phosphate. All three compounds were separated on an lonPac ASH anion exchanger using a NaOH/ methanol mixture as an eluent. Mohsin used an Alltech lOOOHP suppressor to convert the eluent to water prior to entering the MS interface. The Alltech lOOOHP suppressor contains two packed-bed suppressor columns. One of the... [Pg.890]

SPE column of anion exchanger (Alltech), 0.5 meq capacity, OH form Strongly basic anion exchange SPE cartridge... [Pg.155]


See other pages where Anion-exchange columns Alltech is mentioned: [Pg.134]    [Pg.219]    [Pg.84]    [Pg.39]    [Pg.210]    [Pg.46]    [Pg.658]    [Pg.51]    [Pg.200]    [Pg.74]    [Pg.143]    [Pg.178]    [Pg.105]   
See also in sourсe #XX -- [ Pg.134 ]




SEARCH



Alltech

Anion exchange

Anion exchanger

Anionic exchange

Anionic exchangers

Anions anion exchange

Column anion-exchange

Exchange columns

Exchanger column

© 2024 chempedia.info