Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatography quantitative determinations using

Any material with a capillary structure that can be made to adhere as a layer can be used for thin-layer chromatography. Quantitative determinations by this technique are bound to increase as more and more laboratories obtain scanning equipment. This will give impetus to the companies who make commercially-prepared plates to produce them with more care and uniformity. [Pg.130]

The fermentation-derived food-grade product is sold in 50, 80, and 88% concentrations the other grades are available in 50 and 88% concentrations. The food-grade product meets the Vood Chemicals Codex III and the pharmaceutical grade meets the FCC and the United States Pharmacopoeia XK specifications (7). Other lactic acid derivatives such as salts and esters are also available in weU-estabhshed product specifications. Standard analytical methods such as titration and Hquid chromatography can be used to determine lactic acid, and other gravimetric and specific tests are used to detect impurities for the product specifications. A standard titration method neutralizes the acid with sodium hydroxide and then back-titrates the acid. An older standard quantitative method for determination of lactic acid was based on oxidation by potassium permanganate to acetaldehyde, which is absorbed in sodium bisulfite and titrated iodometricaHy. [Pg.515]

To determine the phosphoHpid and fatty acid compositions chromatographic methods (28) like gas chromatography (gc), thin-layer chromatography (tic), and high performance Hquid chromatography (hlpc) are used. Newer methods for quantitative deterrnination of different phosphoHpid classes include P-nmr (29). [Pg.103]

Polymerization-grade chloroprene is typically at least 99.5% pure, excluding inert solvents that may be present. It must be substantially free of peroxides, polymer [9010-98-4], and inhibitors. A low, controlled concentration of inhibitor is sometimes specified. It must also be free of impurities that are acidic or that will generate additional acidity during emulsion polymerization. Typical impurities are 1-chlorobutadiene [627-22-5] and traces of chlorobutenes (from dehydrochlorination of dichlorobutanes produced from butenes in butadiene [106-99-0]), 3,4-dichlorobutene [760-23-6], and dimers of both chloroprene and butadiene. Gas chromatography is used for analysis of volatile impurities. Dissolved polymer can be detected by turbidity after precipitation with alcohol or determined gravimetrically. Inhibitors and dimers can interfere with quantitative determination of polymer either by precipitation or evaporation if significant amounts are present. [Pg.39]

It is important to note that simulated distillation does not always separate hydrocarbons in the order of their boiling point. For example, high-boihng multiple-ring-type compounds may be eluted earher than normal paraffins (used as the calibration standard) of the same boiling point. Gas chromatography is also used in the ASTM D 2427 test method to determine quantitatively ethane through pentane hydrocarbons. [Pg.1326]

Chromatography is a separation process employed for the separation of mixtures of substances. It is widely used for the identification of the components of mixtures, but as explained in Chapters 8 and 9, it is often possible to use the procedure to make quantitative determinations, particularly when using Gas Chromatography (GC) and High Performance Liquid Chromatography (HPLC). [Pg.8]

Ion chromatography (IC) is a relatively new technique pioneered by Small et al.25 and which employs in a novel manner some well-established principles of ion exchange and allows electrical conductance to be used for detection and quantitative determination of ions in solution after their separation. Since electrical conductance is a property common to all ionic species in solution, a conductivity detector clearly has the potential of being a universal monitor for all ionic species. [Pg.197]

High performance liquid chromatography is used for the separation and quantitative analysis of a wide variety of mixtures, especially those in which the components are insufficiently volatile and/or thermally stable to be separated by gas chromatography. This is illustrated by the following method which may be used for the quantitative determination of aspirin and caffeine in the common analgesic tablets, using phenacetin as internal standard where APC tablets are available the phenacetin can also be determined by this procedure. [Pg.233]

The quantitative determination of a component in gas chromatography using differential-type detectors of the type previously described is based upon meas urement of the recorded peak area or peak height the latter is more suitable in the case of small peaks, or peaks with narrow band width. In order that these quantities may be related to the amount of solute in the sample two conditions must prevail ... [Pg.245]

Figure 5.67 Reconstructed ion chromatograms for Idoxifene and internal standard (ds-Idoxifene using LC-ToF-MS for (a) double-blank human plasma extract, (b) extract of blank human plasma containing internal standard (IS), and (c) control-blank human plasma spiked with Idoxifene at 5 gml , the LOQ of the method. Reprinted from 7. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science. Figure 5.67 Reconstructed ion chromatograms for Idoxifene and internal standard (ds-Idoxifene using LC-ToF-MS for (a) double-blank human plasma extract, (b) extract of blank human plasma containing internal standard (IS), and (c) control-blank human plasma spiked with Idoxifene at 5 gml , the LOQ of the method. Reprinted from 7. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science.
It is appropriate at this juncture to illustrate the power of chemiluminescence in an analytical assay by comparing the limits of sensitivity of the fluorescence-based and the chemllumlnescence-based detection for analytes in a biological matrix. The quantitation of norepinephrine and dopamine in urine samples will serve as an illustrative example. Dopamine, norepinephrine, and 3,4-dihydroxybenzy-lamine (an internal standard) were derivatized with NDA/CN, and chemiluminescence was used to monitor the chromatography and determine a calibration curve (Figure 15). The limits of detection were determined to be less than 1 fmol injected. A typical chromatogram is shown in Figure 16. [Pg.151]

Simultaneous evolution of chromatography, as a method of analysis and separation, enables the confirmation and development of chemotaxonomic investigations of new plant species, as well as the accomplishment of quality and quantitative determinations. Thin-layer chromatography (TLC) especially proved to be very useful for analysis and isolation of small amounts of some compounds. The most significant and advantageous points of the TLC technique are its speed, cheapness, and capacity to carry out the analysis of several solutes simultaneously its continuous development under equilibrated conditions its gradient and multiple development and its ability to scale up the separation process. [Pg.252]

There are many proteins in the human body. A few hundreds of these compounds can be identified in urine. The qualitative determination of one or a series of proteins is performed by one of the electrophoresis techniques. Capillary electrophoresis can be automated and thus more quantified (Oda et al. 1997). Newer techniques also enable quantitative determination of proteins by gel electrophoresis (Wiedeman and Umbreit 1999). For quantitative determinations, the former method of decomposition into the constituent amino acids was followed by an automated spectropho-tometric measurement of the ninhydrin-amino add complex. Currently, a number of methods are available, induding spectrophotometry (Doumas and Peters 1997) and, most frequently, ELISAs. Small proteins can be detected by techniques such as electrophoresis, isoelectric focusing, and chromatography (Waller et al. 1989). These methods have the advantage of low detection limits. Sometimes, these methods have a lack of specifidty (cross-over reactions) and HPLC techniques are increasingly used to assess different proteins. The state-of-the-art of protein determination was mentioned by Walker (1996). [Pg.208]

Francesconi, K.A., P. Micks, R.A. Stockton, and K.J. Irgolic. 1985. Quantitative determination of arsenobe-taine, the major water-soluble arsenical in three species of crab, using high pressure liquid chromatography and an inductively coupled argon plasma emission spectrometer as the arsenic-specific detector. Chemosphere 14 1443-1453. [Pg.1536]

Xu X. et al., 2005. Quantitative determination of a novel dual PPAR aly agonist using online turbulent flow extraction with liquid chromatography-tandem mass spectrometry. J Chromatogr B 814 29. [Pg.297]

The majority of the analytical methods for detection of N-nitroso compounds have employed gas chromatography (GC) or liquid chromatography (LC) in conjunction with a thermal energy analyzer (TEA) [20], which relies on the pyrolytic breakdown of N-NO moieties to release the nitrosyl radical. Despite the isolation techniques used, the quantitative determination of N-nitroso compounds requires a concomitant posi-... [Pg.55]

The column chromatography technique using Dowex 50 ion-exchange resin, introduced in 1951 (M2) and improved in 1954 (M3) by Moore and Stein, first made possible the precise quantitative analysis of amino acids liberated in the course of acid hydrolysis of urine. Similar results were also obtained by Muting in 1954 (M4), who used paper chromatography methods. In this procedure amino acids were quantitatively determined after staining on the paper and elution of the resulting spots. [Pg.127]

Tan [71] devised a rapid simple sample preparation technique for analysing polyaromatic hydrocarbons in sediments. Polyaromatic hydrocarbons are removed from the sediment by ultrasonic extraction and isolated by solvent partition and silica gel column chromatography. The sulphur removal step is combined into the ultrasonic extraction procedure. Identification of polyaromatic hydrocarbon is carried by gas chromatography alone and in conjunction with mass spectrometry. Quantitative determination is achieved by addition of known amounts of standard compounds using flame ionization and multiple ion detectors. [Pg.135]


See other pages where Chromatography quantitative determinations using is mentioned: [Pg.382]    [Pg.1246]    [Pg.132]    [Pg.430]    [Pg.148]    [Pg.91]    [Pg.264]    [Pg.315]    [Pg.445]    [Pg.449]    [Pg.286]    [Pg.101]    [Pg.330]    [Pg.401]    [Pg.9]    [Pg.273]    [Pg.263]    [Pg.141]    [Pg.79]    [Pg.465]    [Pg.320]    [Pg.147]    [Pg.335]    [Pg.481]    [Pg.229]    [Pg.230]    [Pg.362]    [Pg.13]    [Pg.34]   
See also in sourсe #XX -- [ Pg.9 ]

See also in sourсe #XX -- [ Pg.9 ]




SEARCH



Chromatography determination

Quantitative chromatography

Quantitative determination