Chromatographic transfer

Prior to the evaluation of solubility and partition data of various solutes, the partition systems and the relevant parameters need to be defined. In the static equilibrium experiments, the notation, solvent (C°)/gel (Cg), refers to the transfer of a solute from the static solvent phase to the gel phase, C° and Cg indicating the molar equilibrium concentrations of the solute in the two phases. When the equilibrium experiment is performed at the saturation of the solute, C° and Cg refer to the solubilities in the external solvent and in the gel phase, respectively. In the gel chromatographic system, mobile phase (C jj)/ gel (Cg, Kgy) refers to the transfer of a solute from the mobile phase to the gel phase, C and Cg indicating the equilibrium molar concentrations of the solute in the two phases, which are correlated each other by Cg/Cuj = The notation, mobile phase (Cjjj)/gel (C°, K° )i applies to the ideal chromatographic transfer process where the distribution coefficient (K° ) Is determined solely by the steric exclusion effect of the gel matrices without any differential interactions of the solute with the two phases. The experimental determination of is subject to some uncertainty as it is difficult to establish such an ideal condition. By inclusion of urea (ref. 40,41,73) and methanol (ref. 41) in the eluents effects other than the purely steric can largely be eliminated, but there is no direct method to confirm the absence of additional gel-solute interactions. This will be further examined later. All the transfer parameters given below are the apparent quantities evaluated using the observed molar concentration data. [Pg.42]

Solid-phase microextractions also have been developed. In one approach, a fused silica fiber is placed inside a syringe needle. The fiber, which is coated with a thin organic film, such as poly(dimethyl siloxane), is lowered into the sample by depressing a plunger and exposed to the sample for a predetermined time. The fiber is then withdrawn into the needle and transferred to a gas chromatograph for analysis. [Pg.213]

Caffeine is extracted from beverages by a solid-phase microextraction using an uncoated fused silica fiber. The fiber is suspended in the sample for 5 min and the sample stirred to assist the mass transfer of analyte to the fiber. Immediately after removing the fiber from the sample it is transferred to the gas chromatograph s injection port where the analyte is thermally desorbed. Quantitation is accomplished by using a C3 caffeine solution as an internal standard. [Pg.226]

To determine how the height of a theoretical plate can be decreased, it is necessary to understand the experimental factors contributing to the broadening of a solute s chromatographic band. Several theoretical treatments of band broadening have been proposed. We will consider one approach in which the height of a theoretical plate is determined by four contributions multiple paths, longitudinal diffusion, mass transfer in the stationary phase, and mass transfer in the mobile phase. [Pg.560]

Thermospray nebulizers are somewhat expensive but can be used on-line to a liquid chromatographic column. About 10% of sample solution is transferred to the plasma flame. The overall performance of the thermospray device compares well with pneumatic and ultrasonic sprays. When used with microbore liquid chromatographic columns, which produce only about 100 pl/min of eluant, the need for spray and desolvation chambers is reduced, and detection sensitivities similar to those of the ultrasonic devices can be attained both are some 20 times better than the sensitivities routinely found in pneumatic nebulizers. [Pg.150]

In the analytical chromatographic process, mixtures are separated either as individual components or as classes of similar materials. The mixture to be separated is first placed in solution, then transferred to the mobile phase to move through the chromatographic system. In some cases, irreversible interaction with the column leaves material permanently attached to the stationary phase. This process has two effects because the material is permanently attached to the stationary phase, it is never detected as leaving the column and the analysis of the mixture is incomplete additionally, the adsorption of material on the stationary phase alters the abiHty of that phase to be used in future experiments. Thus it is extremely important to determine the ultimate fate of known materials when used in a chromatographic system and to develop a feeling for the kinds of materials in an unknown mixture before use of a chromatograph. [Pg.105]

New stationary phases for specific purposes in chromatographic separation are being continually proposed. Charge transfer adsorption chromatography makes use of a stationary phase which contains immobilised aromatic compounds and permits the separation of aromatic compounds by virtue of the ability to form charge transfer complexes (sometimes coloured) with the stationary phase. The separation is caused by the differences in stability of these complexes (Porath and Dahlgren-Caldwell J Chromatogr 133 180 1977). [Pg.25]

Eire protection - Eire extinguishing media - Elalogenated hydrocarbons. Code of practice for safe handling and transfer procedures. Supersedes BS 6535 Section 2.2 1989 Water quality - Gas chromatographic determination of some selected chlorophenols m water. Also BS 6068-2.65 1999... [Pg.591]

It is a common procedure to assume certain conditions for the chromatographic system and operating conditions and, as a result, simplify equations (20) and (21). However, in many cases the assumptions can easily be over-optimistic, to say the least. It is necessary, therefore, to carefully consider the conditions that may allow such simplifying procedures and take steps to ensure that such conditions are carefully met when such expressions are used in practice. Now, the relative magnitudes of the resistance to mass transfer terms will vary with the type of columns (packed or capillary), the type of chromatography (GC or LC) and the type of particle, i.e., porous or microporous (diatomaceous support or silica gel). [Pg.278]

It should be pointed out, however, that the diffusivity of the solute in the mobile phase can be changed in two ways. The solute that is chromatographed can be changed, in which case the above assumptions are clearly valid, as (Ds) is likely to change linearly with (Dm)- However, the solute diffusivity can also be changed by the employing a different mobile phase. In this case, (Dm) will be changed but (Ds) will remain the same. In the second case, the above assumptions are not likely to be precisely correct. Nevertheless, if the resistance to mass transfer in the stationary phase makes only a small contribution to the overall value of (H) (i.e., because df dp (see equation (l)),then the assumption Dm = eDg will still be approximately... [Pg.325]

Manual transfer of the chromatographically separated substance to the detector . These include, for example, the detection of antibiotically active substances, plant and animal hormones, mycotoxins, insecticides, spice and bitter principles and alkaloids. The frequency distribution of their employment is shown in Figure 54 [295]. [Pg.109]

Table 8-10 gives pertinent data for the Menschutkin reaction of triethylamine with ethyl iodide. These reactant molecules are volatile, so their transfer free energies were determined by a gas chromatographic variation of the vapor pressure method. For this reaction Eq. (8-57) is written... [Pg.422]

Figure 2.2 Schematic representation of an on-column interface. The eluent leaving the HPLC detector enters the valve and in the stand-hy position, leaves it to go to waste. When the valve is switched on, the eluent is pumped through the transfer line into the inlet of the on-column injector. The liquid floods the capillary wall, thus creating a layer that will retain the solutes. Evaporation occurs from the rear pait of the solvent so refocusing the chromatographic hand. At the end of the transfer, the valve is switched off, and the eluent again flows to waste. Figure 2.2 Schematic representation of an on-column interface. The eluent leaving the HPLC detector enters the valve and in the stand-hy position, leaves it to go to waste. When the valve is switched on, the eluent is pumped through the transfer line into the inlet of the on-column injector. The liquid floods the capillary wall, thus creating a layer that will retain the solutes. Evaporation occurs from the rear pait of the solvent so refocusing the chromatographic hand. At the end of the transfer, the valve is switched off, and the eluent again flows to waste.
Supercritical fluid extraction (SFE) and Solid Phase Extraction (SPE) are excellent alternatives to traditional extraction methods, with both being used independently for clean-up and/or analyte concentration prior to chromatographic analysis. While SFE has been demonstrated to be an excellent method for extracting organic compounds from solid matrices such as soil and food (36, 37), SPE has been mainly used for diluted liquid samples such as water, biological fluids and samples obtained after-liquid-liquid extraction on solid matrices (38, 39). The coupling of these two techniques (SPE-SFE) turns out to be an interesting method for the quantitative transfer... [Pg.139]

The place at which this transfer occurs is illustrated in Figure 8.19 as a thin circle on the lower chromatographic plate. Because the overpressure is uniform throughout the whole system, the compounds will be divided into two parts and migrate in both circular (outwards) and anticircular (inwords) directions. A hole at the centre of the... [Pg.190]

Multidimensional planar chromatographic separations, as we have seen, require not only a multiplicity of separation stages, but also that the integrity of separation achieved in one stage be transferred to the others. The process of separation on a two-dimensional plane is the clearest example of multidimensional separations. The greatest strength of MD-PC, when properly applied, is that compounds are distributed widely over two-dimensional space of high zone (peak) capacity. Another... [Pg.193]

Mondello et al. (2, 20-23) have used a multidimensional gas chromatographic system based on the use of mechanical valves which were stable at high temperatures developed in their laboratory for the determination of the enantiomeric distribution of monoterpene hydrocarbons (/3-pinene, sabinene and limonene) and monoterpene alcohols (linalol, terpinen-4-ol and a-terpineol) of citrus oils (lemon, mandarin, lime and bergamot). Linalyl acetate was also studied in bergamot oil. The system consisted of two Shimadzu Model 17 gas chromatographs, a six-port two-position valve and a hot transfer line. The system made it possible to carry out fully... [Pg.222]


See other pages where Chromatographic transfer is mentioned: [Pg.156]    [Pg.156]    [Pg.561]    [Pg.567]    [Pg.262]    [Pg.277]    [Pg.279]    [Pg.463]    [Pg.747]    [Pg.1534]    [Pg.1535]    [Pg.123]    [Pg.224]    [Pg.27]    [Pg.10]    [Pg.17]    [Pg.232]    [Pg.259]    [Pg.302]    [Pg.599]    [Pg.166]    [Pg.265]    [Pg.11]    [Pg.18]    [Pg.22]    [Pg.29]    [Pg.59]    [Pg.78]    [Pg.80]    [Pg.125]    [Pg.127]    [Pg.147]    [Pg.186]    [Pg.189]   