Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chemical analysis methods fluorescence

Electron microprobe analysis can be used for the elemental analysis of preceramic polymers and ceramics. However, since these materials are generally quite thermoxidatively stable and thus are not readily amenable to the traditional combustion approach to elemental determination, chemical analysis methods can be complemented by x-ray fluorescence techniques. [Pg.370]

Chemical Properties. Elemental analysis, impurity content, and stoichiometry are determined by chemical or iastmmental analysis. The use of iastmmental analytical methods (qv) is increasing because these ate usually faster, can be automated, and can be used to determine very small concentrations of elements (see Trace AND RESIDUE ANALYSIS). Atomic absorption spectroscopy and x-ray fluorescence methods are the most useful iastmmental techniques ia determining chemical compositions of inorganic pigments. Chemical analysis of principal components is carried out to determine pigment stoichiometry. Analysis of trace elements is important. The presence of undesirable elements, such as heavy metals, even in small amounts, can make the pigment unusable for environmental reasons. [Pg.4]

American Society for Testing Materials, "Symposium on Fluorescent X-ray Spectro-graphic Analysis/ Am, Soc. Testing Materials Spec. Tech. Tubl., No. 157 (1954). W. G. Berl, editor, Physical Methods in Chemical Analysis, Vol. Ill, G. L. Clark, "fluorescent X-ray Spectrometric Analysis," Academic Press, New York, 1956, pages 383-399. [Pg.40]

The active state of luminescence spectrometry today may be judged ly an examination of the 1988 issue of Fundamental Reviews of Analytical Chemistry (78), which divides its report titled Molecular Fluorescence, Phosphorescence, and Chemiluminescence Spectrometry into about 27 specialized topical areas, depending on how you choose to count all the subdivisions. This profusion of luminescence topics in Fundamental Reviews is just the tip of the iceberg, because it omits all publications not primarily concerned with analytical applications. Fundamental Reviews does, however, represent a good cross-section of the available techniques because nearly every method for using luminescence in scientific studies eventually finds a use in some form of chemical analysis. Since it would be impossible to mention here all of the current important applications and developments in the entire universe of luminescence, this report continues with a look at progress in a few current areas that seem significant to the author for their potential impact on future work. [Pg.11]

The reluctance of museum curators and collectors to allow permanent damage to antiquities was, until not long ago, the main reason for the small amount of analytical work done on ancient coins. This was understandable since performing chemical analysis required removing a sample from the coin or damaging its surface, which meant either the destruction or defacement of, at least, a portion of a coin. More recently, however, a number of nondestructive methods of analysis such as neutron activation, X-ray fluorescence, and some techniques of surface analysis have been successfully applied to obtain information about ancient coins and the people and societies involved in their production (Carter 1993 Barrandon et al. 1977). [Pg.233]

Moens, L., A. Von Bohlen, and P. Vandenabeele (2000), X ray fluorescence, in Cilib-erto, E. and G. Spoto (eds.), Modern Analytical Methods in Art and Archaeology, Chemical Analysis Series, Vol. 155, Wiley, New York. [Pg.599]

Photothermal Spectroscopy Methods for Chemical Analysis. By Stephen E. Bialkowski Element Speclatlon in Bioinorganic Chemistry. Edited by Sergio Caroli Laser-Enhanced Ionization Spectrometry. Edited by John C. Travis and Gregory C. Turk Fluorescence Imaging Spectroscopy and Microscopy. Edited by Xue Feng Wang and Brian Herman... [Pg.654]

Another method to detect energy transfer directly is to measure the concentration or amount of acceptor that has undergone an excited state reaction by means other than detecting its fluorescence. For instance, by chemical analysis or chromatographic analysis of the product of a reaction involving excited A [117, 118]. An early application of this determined the photolyzed A molecules by absorption spectroscopic analysis. [119-121], This can be a powerful method, because it does not depend on expensive instrumentation however, it lacks real-time observation, and requires subsequent manipulation. For this reason, fluorescence is the usual method of detection of the sensitized excitation of the acceptor. If it is possible to excite the donor without exciting the acceptor, then the rate of photolysis of the acceptor (which is an excited state reaction) can be used to calculate the FRET efficiency [122],... [Pg.58]

In some manufacturing process analysis applications the analyte requires sample preparation (dilution, derivatization, etc.) to afford a suitable analytical method. Derivatization, emission enhancement, and other extrinsic fluorescent approaches described previously are examples of such methods. On-line methods, in particular those requiring chemical reaction, are often reserved for unique cases where other PAT techniques (e.g., UV-vis, NIR, etc.) are insufficient (e.g., very low concentrations) and real-time process control is imperative. That is, there are several complexities to address with these types of on-line solutions to realize a robust process analysis method such as post reaction cleanup, filtering of reaction byproducts, etc. Nevertheless, real-time sample preparation is achieved via an on-line sample conditioning system. These systems can also address harsh process stream conditions (flow, pressure, temperature, etc.) that are either not appropriate for the desired measurement accuracy or precision or the mechanical limitations of the inline insertion probe or flow cell. This section summarizes some of the common LIF monitoring applications across various sectors. [Pg.349]

ANALYZER (Reagent-Tape). The key to chemical analysis by this method is a tape (paper or fabric) that has been impregnated with a chemical substance that reacts with the unknown to form a reaction product on the tape which lias some special characteristic, e.g., color, increased or decreased opacity, change in electrical conductance, or increased or lessened fluorescence. Small pieces of paper treated with lead acetate, for example, have, been used manually by chemists for many years to determine the presence of hydrogen sulfide in a solution or in the atmosphere. This basic concept forms the foundation for a number of sophisticated instruments that may pietreat a sample gas, pass it over a cyclically advanced tape, and, for example, photo-metrically sense the color of the exposed tape, to establish a relationship between color and gas concentration. Depending upon tile type uf reactiun involved, the tape may he wet or dry and it may be advanced continuously or periodically. Obviously, there are many possible variations within the framework of this general concept. [Pg.98]

Asbestos can be determined by several analytical techniques, including optical microscopy, electron microscopy, X-ray diffraction (XRD), light scattering, laser microprobe mass analysis, and thermal analysis. It can also be characterized by chemical analysis of metals by atomic absorption, X-ray fluorescence, or neutron activation techniques. Electron microscopy methods are, however, commonly applied for the analysis of asbestos in environmental matrices. [Pg.283]

The application of analytical methods to speciation measurements in complicated systems has remained rather limited, despite the considerable technological progress during the past 25 years. The characterisation methods (e.g. spectroscopy, nuclear magnetic resonance) are often limited to the study of isolated compounds at relatively high concentrations. They, therefore, necessitate the prior employment of sophisticated separation and pre-concentration methods which introduce severe risks of perturbation. The trace analysis methods are often insensitive to the chemical form of the elements measured (e.g. atomic absorption, neutron activation). Those which possess sufficient element specificity (e.g. electron spin resonance, fluorescence, voltammetry) still require significant development before their full potential can be realised. [Pg.188]

They used X-ray fluorescent method to do chemical analysis of the received materials and diffractometer DRON-3M for roentgen-phase analysis (Ka-Cu radiation with graphite monochromator). For comparison they referred to data of PDF (Powder Difraction File) Bank. Sorbtion characteristics (pressure of hydride formation and sorbtion capacity) were defined by means of P-C isotherms drawing while received materials interact with hydrogen in the apparatus of Cubeptca type (Sieverts - type apparatus). [Pg.409]

Flame Spectrometry in Environmental Chemical Analysis A Practical Guide is a simple, user-friendly guide to safe flame spectrometric methods for environmental samples. It explains key processes involved in achieving accurate and reliable results in atomic absorption spectrometry, atomic fluorescence spectrometry and flame emission spectrometry, showing the inter-relationship of the three techniques, and their relative importance. [Pg.110]


See other pages where Chemical analysis methods fluorescence is mentioned: [Pg.633]    [Pg.395]    [Pg.397]    [Pg.366]    [Pg.468]    [Pg.6]    [Pg.448]    [Pg.455]    [Pg.554]    [Pg.139]    [Pg.258]    [Pg.226]    [Pg.289]    [Pg.157]    [Pg.10]    [Pg.535]    [Pg.468]    [Pg.58]    [Pg.75]    [Pg.372]    [Pg.226]    [Pg.347]    [Pg.945]    [Pg.584]    [Pg.690]    [Pg.123]    [Pg.4]    [Pg.303]   
See also in sourсe #XX -- [ Pg.213 , Pg.214 , Pg.215 ]




SEARCH



Fluorescence analysis

Fluorescence methods

Fluorescent analysis (

Fluorescent method

© 2024 chempedia.info