Capacity analytical

The suppressor column obviously will eventually become depleted and will have to be regenerated (with HCl for the cation exchanger and with NaOH for the anion exchanger). The suppressor column is usually a small-volume bed of a high-capacity resin to minimize band spreading in the colunm. Since microgram or smaller quantities of analytes are usually separated, a low-capacity analytical column is used coupled with relatively low eluent concentration (1 to 10 mM). [Pg.626]

The advent of high-performance conductivity detectors with a wide dynamic range and electronic suppression of background conductance has allowed the development of ion chromatography without a suppressor column. A low-capacity analytical column is combined with low-concentration eluent, typically phthalate buffers, for anion measurements. The advantages of avoiding a suppressor colunm... [Pg.626]

Used in virtually all organic chemistry analytical laboratories, gas chromatography has a powerful separation capacity. Using distillation as an analogy, the number of theoretical plates would vary from 100 for packed columns to 10 for 100-meter capillary columns as shown in Figure 2.1. [Pg.20]

Although the previous paragraphs hint at the serious failure of the van der Waals equation to fit the shape of the coexistence curve or the heat capacity, failures to be discussed explicitly in later sections, it is important to recognize that many of tlie other predictions of analytic theories are reasonably accurate. For example, analytic equations of state, even ones as approximate as that of van der Waals, yield reasonable values (or at least ball park estmiates ) of the critical constants p, T, and V. Moreover, in two-component systems... [Pg.622]

The integral under the heat capacity curve is an energy (or enthalpy as the case may be) and is more or less independent of the details of the model. The quasi-chemical treatment improved the heat capacity curve, making it sharper and narrower than the mean-field result, but it still remained finite at the critical point. Further improvements were made by Bethe with a second approximation, and by Kirkwood (1938). Figure A2.5.21 compares the various theoretical calculations [6]. These modifications lead to somewhat lower values of the critical temperature, which could be related to a flattening of the coexistence curve. Moreover, and perhaps more important, they show that a short-range order persists to higher temperatures, as it must because of the preference for unlike pairs the excess heat capacity shows a discontinuity, but it does not drop to zero as mean-field theories predict. Unfortunately these improvements are still analytic and in the vicinity of the critical point still yield a parabolic coexistence curve and a finite heat capacity just as the mean-field treatments do. [Pg.636]

That analyticity was the source of the problem should have been obvious from the work of Onsager (1944) [16] who obtained an exact solution for the two-dimensional Ising model in zero field and found that the heat capacity goes to infinity at the transition, a logarithmic singularity tiiat yields a = 0, but not the a = 0 of the analytic theory, which corresponds to a finite discontinuity. (Wliile diverging at the critical point, the heat capacity is synnnetrical without an actual discontinuity, so perhaps should be called third-order.)... [Pg.644]

Although the chiral recognition mechanism of these cyclodexttin-based phases is not entirely understood, thermodynamic and column capacity studies indicate that the analytes may interact with the functionalized cyclodextrins by either associating with the outside or mouth of the cyclodextrin, or by forming a more traditional inclusion complex with the cyclodextrin (122). As in the case of the metal-complex chiral stationary phase, configuration assignment is generally not possible in the absence of pure chiral standards. [Pg.71]

Analytical balances are higher accuracy laboratory balances with capacities up to 400 g, and up to 20 million displayed divisions. [Pg.332]

An analytical model of the process has been developed to expedite process improvements and to aid in scaling the reactor to larger capacities. The theoretical results compare favorably with the experimental data, thereby lending vahdity to the appHcation of the model to predicting directions for process improvement. The model can predict temperature and compositional changes within the reactor as functions of time, power, coal feed, gas flows, and reaction kinetics. It therefore can be used to project optimum residence time, reactor si2e, power level, gas and soHd flow rates, and the nature, composition, and position of the reactor quench stream. [Pg.393]

Analytical information taken from a chromatogram has almost exclusively involved either retention data (retention times, capacity factors, etc.) for peak identification or peak heights and peak areas for quantitative assessment. The width of the peak has been rarely used for analytical purposes, except occasionally to obtain approximate values for peak areas. Nevertheless, as seen from the Rate Theory, the peak width is inversely proportional to the solute diffusivity which, in turn, is a function of the solute molecular weight. It follows that for high molecular weight materials, particularly those that cannot be volatalized in the ionization source of a mass spectrometer, peak width measurement offers an approximate source of molecular weight data for very intractable solutes. [Pg.335]

Column design involves the application of a number of specific equations (most of which have been previously derived and/or discussed) to determine the column parameters and operating conditions that will provide the analytical specifications necessary to achieve a specific separation. The characteristics of the separation will be defined by the reduced chromatogram of the particular sample of interest. First, it is necessary to calculate the efficiency required to separate the critical pair of the reduced chromatogram of the sample. This requires a knowledge of the capacity ratio of the first eluted peak of the critical pair and their separation ratio. Employing the Purnell equation (chapter 6, equation (16)). [Pg.367]

The analytical capability of a SEC column is sometimes judged by the peak capacity, which is the number of unique species that can be resolved on any given SEC column. This number will increase with decreased particle size, increased column length, and increased pore volume. Because small particlesized medium generally has a lower pore volume and a shorter column length, peak capacities of ca. 13 for fully resolved peaks can be expected for high-resolution modern media as well as traditional media, (see Eig. 2.5). It was found that SEC columns differ widely in pore volume, which affects the effective peak capacity (Hagel, 1992). [Pg.35]

Por analytical purposes, TSK-GEL PWxl columns are preferred. Por preparative work, or for other cases in which large amounts of sample must be used, TSK-GEL PW columns are recommended because of their larger loading capacity. To select the proper TSK-GEL PW type column for a particular sample, consult the separation ranges listed in Table 4.6 or the calibration curves in Pig. 4.11. [Pg.108]

The actual loading capacity always depends on the sample composition and the separation problem. As a rule the volume of the loaded sample should not exceed 5% of the column volume. However, this recommendation is valid only for preparative runs. For analytical applications when a high resolution is needed, the volume of the injected sample should be about 1% of the total column volume or even less. For a preparative run on a 1000 X 200-mm column (bed height 60 cm), two different sample volumes were injected. If the sample volume is 0.3% of the total bed volume, the separation is more efficient... [Pg.233]

A second way to achieve constancy of a reactant is to make use of a buffer system. If the reaction medium is water and B is either the hydronium ion or the hydroxide ion, use of a pH buffer can hold Cb reasonably constant, provided the buffer capacity is high enough to cope with acids or bases generated in the reaction. The constancy of the pH required depends upon the sensitivity of the analytical method, the extent of reaction followed, and the accuracy desired in the rate constant determination. [Pg.24]

In common with all multidimensional separations, two-dimensional GC has a requirement that target analytes are subjected to two or more mutually independent separation steps and that the components remain separated until completion of the overall procedure. Essentially, the effluent from a primary column is reanalysed by a second column of differing stationary phase selectivity. Since often enhancing the peak capacity of the analytical system is the main goal of the coupling, it is the relationship between the peak capacities of the individual dimensions that is crucial. Giddings (2) outlined the concepts of peak capacity product and it is this function that results in such powerful two-dimensional GC separations. [Pg.46]


See other pages where Capacity analytical is mentioned: [Pg.325]    [Pg.1222]    [Pg.1222]    [Pg.1222]    [Pg.1071]    [Pg.1095]    [Pg.169]    [Pg.325]    [Pg.1222]    [Pg.1222]    [Pg.1222]    [Pg.1071]    [Pg.1095]    [Pg.169]    [Pg.564]    [Pg.639]    [Pg.644]    [Pg.127]    [Pg.196]    [Pg.445]    [Pg.589]    [Pg.593]    [Pg.778]    [Pg.105]    [Pg.66]    [Pg.67]    [Pg.255]    [Pg.388]    [Pg.406]    [Pg.104]    [Pg.106]    [Pg.109]    [Pg.2055]    [Pg.75]    [Pg.314]    [Pg.422]    [Pg.423]    [Pg.304]    [Pg.306]    [Pg.28]    [Pg.1]   
See also in sourсe #XX -- [ Pg.40 ]