Breakers control switches

To close or trip the interrupter locally or retnotely a breaker control switch is also wired with the closing and the shunt trip coils of the interrupter, as shown in Figure... [Pg.383]

Breaker control switch (spring return to neutral) (C - closed, N - neutral. T - trip) M Motor... [Pg.391]

A motor control center (MCC) contains a number of enclosed motor control switches and breakers on a common power bus. MCCs should be of non-... [Pg.309]

One of the most important criteria for the selection of a site for the installation of automation or remote-controlled element in the existing overhead lines of medimn voltage is the finding of optimum number of points in which the installation of these modem devices will be the most economical and effective. The determination of points (existing and also new disconnecting points in the hnes), in which the replacement by or installation of a new remote-controlled switch-disconnector (RCSD) or remote-controlled circuit-breakers (Recloser) is to be perfor-med, means to create and determine importance-based criteria the fulfilment of which win be the precondition for the best return on investments made. [Pg.1836]

Service equipment. The necessary equipment, usually consisting of a circuit breaker or switch and fuses, and their accessories, located near the point of entrance of supply conductors to a building or other structure, or an otherwise defined area, and intended to constitute the main control and means of cutoff of the supply. [Pg.482]

A process technician typically traces power to the unit from a motor control center (MCC). The primary components of an electrical system are the MCC, motors, transformers, breakers, fuses, switch gears, starters, and switches. Specific safety rules apply to the operation of electrical systems. The primary safety system is the isolation of hazardous energy through lock-out/tag-out measures. Process technicians are required to have training in this area. Figure 7-22 shows the basic symbols and flow path associated with an electrical drawing. Electrical lines are typically run in cable trays to switches, motors, ammeters, substations, and control rooms. [Pg.189]

First, locate your home s circuit breaker box. Inside the box are voltage-controlled switches that automatically turn off the power if the fixtures and appliances plugged into the circuit overdraw the board. In other words, rather than frying the system, the breaker box turns it off. You can also use these circuit breakers to manually shut off power to different parts of the house. The breakers should be labeled according to the areas they protect. If not, think about the things that draw electricity in your house— would it be harmful to momentarily turn any of these things off If it... [Pg.349]

Remote circuit breaker switching allows service personnel to stand outside the arc flash protection boundary while operating the control switches... [Pg.23]

For oil-filled control equipment such as autotransformer starters or oil circuit breakers (BOCBs or MOCBs, Chapter 19), insulating oil should be checked periodically for its insulating properties. Leading manufacturers of this equipment indicate the number of switching operations under different conditions of load and fault, after which the oil must be replaced and these must be followed. [Pg.235]

With the availability of 3.3 and 6.6 kV vacuum contactors the control of HT motors up to 6.6 kV systems has now become easier and economical, compact and even more reliable. For 11 kV. systems, vacuum as well as SF (Sulphur hexafluoride) breakers can be used. The HT motor s switching and protection through a vacuum contactor provides a replica of an LT system. The earlier practice of using an HT OCB, MOCB, or an air blast circuit breaker for the interruption of an HT circuit is now a concept of the past. [Pg.308]

The two comparatively new type of breakers, vacuum and SFg are exceptions and have gained favour in view of their reliability and durability. For details on these breakers, see Sections 19.5.5 and 19.5.6, which also deal with their switching behaviour and phenomenon of arc reignition. Figures 12.44 and 12.45 illustrate typical power and control circuit diagrams respectively, for a 6.6 kV breaker-operated motor starter. [Pg.308]

These assemblies are fitted with switching devices (breakers, switches, fuse switches and contactors etc.) and control and measuring instruments, indicating, regtilating and protective devices etc. to transform the assemblies into composite units, called control centres to perform a number of functions in the field of distribution and control of electrical power. Some of these functions may be one or more of the following ... [Pg.335]

With the advance of the turbine to idle speed, the turbine is ready to synchronize, and control is considered in synchronization. Both manual and automatic synchronizing are available locally. The unit is synchronized, and the main breaker closed. The speed reference will be switched to become a load reference. The speed/load reference will be automatically increased at a predetermined rate so that the fuel valve will be at the approximate position required for the desired load. For maintenance scheduling, the computer will count the number of normal starts and accumulate the number of hours at the various load levels. [Pg.644]

Seals are required at entries by conduit or cable to explosion-proof enclosures containing arcing or high-temperature devices in Division 1 and Division 2 locations. It is not required to seal IM in. or smaller conduits into explosion-proof enclosures in Division 1 areas housing switches, circuit breakers, fuses, relays, etc., if their current-interrupting contacts are hermetically sealed or under oil (having a 2-in. minimum immersion for power contacts and 1-in. for control contacts). [Pg.539]

In addition to circuit breakers, there are other classes of automatic switches that can be controlled or operated remotely, but with current-interrupting capability. These include circuit switchers, reclosers, and sectionalizers. [Pg.430]

Capacitors as bulk units can be connected to the supply busbar via a fuse switch, molded-case circuit breaker of air circuit breaker. In this type of installation control is purely manual, and in cases of a reasonably constant load and where the amount of power factor correction is limited such a manually controlled system is perfectly adequate. The supply authority may, however, require to be informed that a capacitor bank is permanently connected to the supply. Capacitors are more generally connected either in banks controlled from a VAR sensitive relay or across individual loads (e.g. motors). [Pg.221]

Service equipment- Main control gear at the service entrance, such as circuit breakers, switches, and fuses. [Pg.279]

Vacuum systems are electrically switched and monitored throughout the installation. Many vacuum systems require a motor-protective circuit-breaker and an On/Off button, or the signals from the level, temperature and pressure monitoring components are processed in a controller. [Pg.321]

Most circuits also contain a switch that controls the flow of electrons along the pathway. Another component that may be included in the pathway is a fuse or circuit breaker. Fuses and circuit breakers are safety devices. When the flow of electrons—amperage—exceeds the value of the fuse, then the extra current flow causes the fuse to overheat and melt, thus breaking the circuit. In a circuit breaker, the extra current flow initiates an electromagnet that opens a switch and interrupts the flow of electrons. [Pg.289]

Uses Engineering plastic domestic power tools cooker components elec, plugs/sockets/switches/circuit breaker housings automotive parts blends with PC pump housings impellers gears hinges antistat, film-former, vise, control agent in cosmetics... [Pg.3442]

It is easy to operate, has fine temperature control, and is clean, but it is very costly. It needs accessories as transformer, circuit breakers, and cables/bus bars of adequate rating for high currents, instruments such as ammeter, voltmeter, KW and KWH meters, and temperature controller thermostats (to switch on and switch ofif power automatically as per need), or by adjusting the power input by controlling the voltage across the electrodes. [Pg.233]

This paper dealt with systems for remote control of switch-disconnectors (RCSD) and circuit-breakers (Reclosers), whose introduction into the outdoor medium voltage networks leads to improved reliability of power supply. These remote-controlled elements currently serve for replacement of the manually-controlled section disconnectors, which do not enable... [Pg.1839]

To illustrate the implementation of remote-controlled systems within electrical distribution networks and their contribution to improvement in reli-abftity of electric energy supply to customers, we conducted an analysis of effects produced by the remote-controlled devices (Distribution substations within municipal underground system. Section switch-disconnectors and circuit-breakers in over-head hnes) to operation parameters of a selected section of the electrical distribution network in the Northern Moravia (Czech Republic). [Pg.1845]


See other pages where Breakers control switches is mentioned: [Pg.383]    [Pg.510]    [Pg.383]    [Pg.510]    [Pg.475]    [Pg.1835]    [Pg.1842]    [Pg.191]    [Pg.271]    [Pg.434]    [Pg.272]    [Pg.457]    [Pg.131]    [Pg.381]    [Pg.523]    [Pg.834]    [Pg.916]    [Pg.270]    [Pg.221]    [Pg.157]    [Pg.18]    [Pg.374]    [Pg.162]    [Pg.16]    [Pg.1291]    [Pg.132]    [Pg.154]    [Pg.155]    [Pg.1841]   
See also in sourсe #XX -- [ Pg.383 ]