Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Background, avoidance

Are excessive differences in brightness between disf ays and background avoided Do the scale divisions and the accuracy of the instrument correspond to the required reading accuracy ... [Pg.228]

The international debt crisis was brought about by Western bankers in search of quick profit and is now one of our most pressing problems. This book looks at the background and shows what we must do to avoid disaster. [Pg.445]

Measurements of ozone concentration in the ozone layer in the stratosphere are made in the less intense Huggins band to avoid complete absorption of the laser radiation. Again, the two or three wavelength DIAL method is used to make allowance for background aerosol scattering. A suitable laser for these measurements is the XeCl pulsed excimer laser (see Section 9.2.8) with a wavelength of 308 nm, close to the peak absorption of the Huggins... [Pg.381]

In order to select the instmmental conditions for carrying out the ATR measurements several parameters including the number of accumulated scans per spectra or nominal resolution were tested. To avoid the crosscontamination and to establish an appropriate strategy for cleaning the ATR cell between samples, several procedures were tested using background and blank controls. Moreover, the possible sample sedimentation on the ATR plate cell due to the complexity of the sample matrix during the spectra acquisition was also checked. [Pg.142]

The comparison with experiment can be made at several levels. The first, and most common, is in the comparison of derived quantities that are not directly measurable, for example, a set of average crystal coordinates or a diffusion constant. A comparison at this level is convenient in that the quantities involved describe directly the structure and dynamics of the system. However, the obtainment of these quantities, from experiment and/or simulation, may require approximation and model-dependent data analysis. For example, to obtain experimentally a set of average crystallographic coordinates, a physical model to interpret an electron density map must be imposed. To avoid these problems the comparison can be made at the level of the measured quantities themselves, such as diffraction intensities or dynamic structure factors. A comparison at this level still involves some approximation. For example, background corrections have to made in the experimental data reduction. However, fewer approximations are necessary for the structure and dynamics of the sample itself, and comparison with experiment is normally more direct. This approach requires a little more work on the part of the computer simulation team, because methods for calculating experimental intensities from simulation configurations must be developed. The comparisons made here are of experimentally measurable quantities. [Pg.238]

The chromatogram is freed from mobile phase in a stream of warm air, dipped in dipping solution I for 3 s, then heated to 120°C for 5 —10 min, cooled to room temperature and then immersed in dipping solution II for 3 s. The final drying of the chromatogram should take place in a stream of cold air in order to avoid strong background coloration. [Pg.266]

Note Traces of ammonia left by the mobile phase should be completely removed from the chromatograms before the reagent is applied in order to avoid strong background coloration. The dipping solutions may also be applied as spray solutions. Secondary amines, amides, pyrimidines and purines do not react with the reagent [1]. In the case of benzodiazepines only those substances react which... [Pg.266]

Note Traces of ammonia from the mobile phase should be removed from the plate completely to avoid background discoloration (grey veil) [1]. If the layer is sprayed too heavily the initially grey-black chromatogram zones can fade again [2]. The reagent which is usually employed as a 1 to 2% solution [2, 3, 6, 7] can be treated with a few drops of nitric acid to clarify the solution [2]. [Pg.338]

Note The background coloration could be avoided if the dipped chromatogram was stored in a chamber first over streaming moist nitrogen gas for 15 min and... [Pg.370]

Computer viruses are rather like AIDS. To avoid infection, do not promiscuously share data or disks, and keep the covers on your disks in the presence of computers whose background is unknown. [Pg.363]

It is very important to understand that an insurance policy is a legal document, and insurance negotiations should be approached on this basis. Insurance contracts have a detailed legal background of both case law and common law in the interpretation of their provisions. Professional insurance advice from a reputable source, whether an insurance company or an insurance broker, is essential if problems are to be avoided. [Pg.163]

There are two methods for overcoming these disadvantages. In the first the precipitation of silver cyanoargentate at the end point can be avoided by the addition of ammonia solution, in which it is readily soluble, and if a little potassium iodide solution is added before the titration is commenced, sparingly soluble silver iodide, which is insoluble in ammonia solution, will be precipitated at the end point. The precipitation is best seen by viewing against a black background. [Pg.358]

It is sometimes convenient to use a properly chosen scattered line in the background for comparison to avoid having to add an internal standard to the sample.37 The experience of the Applied Research Laboratories shows that the effects of variations or fluctuations in the equipment and of particle size in powdered samples can be eliminated satisfactorily in this way. In some cases, absorption and enhancement effects are also adequately compensated. We have already mentioned (7.8) that scattered reference line and the analytical line will be subject to considerably different absorption effects if the two lines differ appreciably in wavelength. Everything depends upon the selection of a satisfactory scattered reference line, and this is done empirically. [Pg.191]

It was found essential to maintain cleanliness around the Coulter Counter at all times. Dust and moisture must be avoided or high background counts and instability will result. The Coulter Counter analysis was found to be more rapid than the Micromerograph, requiring approximately 15 minutes per analysis as compared to 90 minutes for high surface material on the Micromerograph. The use of a multichannel Coulter Counter would reduce the time per analysis to less than five minutes... [Pg.533]

Two key parameters have been found to determine the ultimate eapabili-ties of the MOEMS-based MOS contrast and spectral photometric variation (SPV). Contrast is dehned as the total amount of non-selected flux of light passing through the multi-slit device a contrast requirement of 2000 has been established in order to avoid pollution of the spectra by strong sources (spoilers) and sky background. The SPV is the unpredictable photometric variation due to the random position of the sources on the PMSM grid SPV requirement has been fixed to <10%. [Pg.112]

Brief exposure to nitrous fumes (up to 3 min) leaves the fluorescent power of the acid-instable fluorescence indicator 254. incorporated into most TLC layers, largely unaffected, so that the nitroaromatics so formed can be detected as dark zones on a green fluorescent background [1]. For purposes of in situ quantitation it is recommended that the fluorescence indicator be destroyed by 10 min exposure to nitrous fumes in order to avoid difficulties in the subsequent evaluation [1]. [Pg.172]

So far no hypotheses are required concerning the true shape of the peak profile. Flowever, in order to avoid or reduce the difficulties related to the overlapping of the peaks, the experimental noise, the resolution of the data and the separation peak-background, the approach most frequently used fits by means of a least squared method the diffraction peaks using some suitable functions that allow the analytical Fourier transform, as, for example, Voigt or pseudo-Voigt functions (4) which are the more often used. [Pg.134]

The 99 keV y-quanta are usually counted with Nal(Tl) scintillation counters or Ge(Li) diodes in transmission geometry. A Cd absorber should be used to reduce the background counting rate of the K X-rays and to avoid pile-up of the different X- and y-rays (cf. Fig. 4 in [325]). [Pg.341]

More recently, liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) have been evaluated as possible alternative methods for carfentrazone-ethyl compounds in crop matrices. The LC/MS methods allow the chemical derivatization step for the acid metabolites to be avoided, reducing the analysis time. These new methods provide excellent sensitivity and method recovery for carfentrazone-ethyl. However, the final sample extracts, after being cleaned up extensively using three SPE cartridges, still exhibited ionization suppression due to the matrix background for the acid metabolites. Acceptable method recoveries (70-120%) of carfentrazone-ethyl metabolites have not yet been obtained. [Pg.488]


See other pages where Background, avoidance is mentioned: [Pg.108]    [Pg.288]    [Pg.1]    [Pg.505]    [Pg.80]    [Pg.257]    [Pg.92]    [Pg.369]    [Pg.181]    [Pg.85]    [Pg.241]    [Pg.794]    [Pg.111]    [Pg.408]    [Pg.54]    [Pg.687]    [Pg.36]    [Pg.56]    [Pg.430]    [Pg.656]    [Pg.453]    [Pg.69]    [Pg.115]    [Pg.173]    [Pg.69]   


SEARCH



© 2024 chempedia.info