Auto calibration

The Petco2 falls rapidly over the course of a few breaths. With hyperventilation, the fall would be slower. Any condition that acutely reduces cardiac output may be the cause, including cardiac arrest, pulmonary embolism or acute rhythm disturbances. If the Pco2 falls instantly to zero, then the cause is disconnection, auto-calibration or equipment error. [Pg.60]

Some important gas and vapor detection system features to consider when selecting a system are self-checking, auto-calibrating or self-diagnosing capabilities with sensor out-of-service, or malfunction alarming. [Pg.196]

The mode of calibration is determined by the design of the instrument. Most instruments contain a barometer or a transducer responsive to P(Amb) so that barometric pressure is always known to the microprocessor. With such instruments, only a keyboard entry of the fractional composition of O2 and CO2 in low and high calibrator gas mixtures needs to be made. Today, most analyzers auto-calibrate without the necessity for user input. The microprocessor will calculate the values for PO2 and PCO2 (according to Dalton s law) for gases saturated with water vapor at 37 °C. [Pg.1010]

Twin Cond is a conductivity meter, available from HORIBA Jobin Yvon, which features a waterproof flat sensor. Twin Cond can measure the conductivity of a solution from a single drop of sample and is therefore very suitable for both field measurements in rivers and lakes and for rain samples. It features a measurement range from 1 p,S/cm to 19.9 mS/cm. It also has one-touch auto-calibration, automatic temperature conversion and a salinity conversion function (from 0-1.1 %). Multiparameter meters can test for pH, conductivity, total dissolved solids and temperature in the one device. [Pg.210]

With the advent of microprocessor on line high speed calorimeters can be monitored to assure reliable calibration and control for reproducible control of the desired set point. SMARTCAL (tm) is such a dedicated microprocessor to interface with calorimeters for auto-calibration and various diagnostic and alarm functions to assure on-line reliability. [Pg.137]

Daily auto-calibration including control for the customers sample line transfer values. [Pg.194]

It is appropriate to point out that there are two calibration techniques used with SMART-CAL. One technique is used for start up and for periodic service such as that done on a six month basis. The second technique is the one used for auto-calibration. [Pg.194]

Rowe, G. L, Yi, J. H., Chiu, K. G., Tan, J., Mamishev, A. V. and Minaie, B., Fill-front and cure progress monitoring for VARTM with auto-calibrating dielectric sensors . In SAMPE 2005 Symposium and Exhibition, Long Beach, CA, May 2005. [Pg.309]

The switch configuration is stored as a vector of noughts and ones in two, 8-bit bytes. Each configuration is therefore represented by a unique 16-bit word which is stored in the memory space of the controlling digital processor. The sub-system can be switched into a specific self-check or auto-calibration mode with only a few control instructions [17]. [Pg.314]

Controller Functions Limit switches, Auto-Zero, Peak-to-Peak, Minimum, Maximum, Average, Storage of 3 configurations (calibrations) ... [Pg.253]

QQ Start-up routine, calibration routine, data transfer/backup, data integrity, power failure, auto lock off, human-machine interface, security access/audit trail, system stress test in event of power failure, alarm tests, operator data entry tests... [Pg.304]

Other auto-pipettes need periodic calibration for Good Manufacturing Practice (GMP) operation. [Pg.130]

Standardization of a Titrant For wet chemistry analytical methods, a titration is often used and the titrant, or the solution to which an unknown sample is compared, must be standardized. This can be done by comparing it with another standard. The important thing here is that the standard with which it is compared is ultimately traced to a SRM. The procedure utilizes volumetric glassware heavily, and thus the analyst must be assured that these are properly calibrated, as discussed above. Auto-titrators can be used (Figure 5.4). In this case, the automated equipment can be calibrated against manual equipment, i.e., volume readings obtained with the auto-titrator must match the volume readings obtained with a calibrated buret for the same sample. If they do not match (within accepted limits), the auto-titrator must be taken out of service and repaired, just like the defective balance. [Pg.33]

SEC is measured with a conductivity meter, which normally consists of an AC bridge and a conductivity cell or electrodes. The conductance is measured between two electrodes. Two solutions of known conductivity should be used, one to calibrate the metre and the other to check the slope. It is important to correct all data for water temperature, either by calculation or by automatically using the metre s auto-temperature correction mode, since SEC is highly dependent on temperature. SEC increases by about 2% per degree centigrade rise in temperature due principally to an increase in water viscosity. [Pg.43]

Horiba LA-300 is a compact instrument with a built-in auto-alignment function. This feature not only maintains ideal operating conditions but self-calibrates with the touch of a button. Measurements are performed using a 650 nm laser diode, six wide-angle detectors and a 36 channel ring-shaped silicon diode array detector... [Pg.556]

Program the auto-injector for a run time of 44 min three injections from the first position, and one injection from the other position. The third injection of standard from the first position is used for calibration,... [Pg.104]

In an effort to reduce emissions from mobile sources to help address acute ozone nonattainment problems, the State of California adopted a Low Emission Vehicle/Clean Fuel program in 1990. Low Emission Vehicles, or LEVs, are designed to meet significantly stricter HC, CO and NOx standards than vehicles sold in the remainder of the U.S., and are designed to operate on a strictly controlled reformulated fuel to achieve low emissions over the vehicle s lifetime. One of the characteristics of this fuel is a low sulfur content, which averages 30-40 ppm or less. Data provided by the Auto Oil Air Quality Research Program and other studies were instrumental in the development of the low emission properties of this fuel, and vehicle manufacturers now use this fuel in the development, calibration, and certification process for Low Emission Vehicles sold in California. [Pg.21]

Consideration of the analyses performed on the 8-channel and both models of the 12-channel Technicon equipment in relation to the earlier discussion means that these latest developments in the field of Auto-Analyzer instrumentation demand standardized sera for calibration purposes. In fact, the successful operation of the SMA-12 instrument is entirely dependent upon the careful analysis and subsequent stability of the standardizing serum, since this is used both for the initial calibration of the various analytical channels and for the subsequent monitoring for drift and application of any correction needed as a result of instrumental drift. Apart from this large demand for standardizing serum (about 70 ml in an 8-hour day), the performance of the SMA-12 should in addition be checked by means of control sera, as for any other method or combination of methods in clinical chemistry. The expense of the standardizing (and to a lesser extent the control) sera used in SMA-12 operation constitutes an important but nevertheless essential fraction of the operating costs of these instruments. [Pg.88]


See other pages where Auto calibration is mentioned: [Pg.351]    [Pg.77]    [Pg.212]    [Pg.194]    [Pg.251]    [Pg.313]    [Pg.244]    [Pg.351]    [Pg.77]    [Pg.212]    [Pg.194]    [Pg.251]    [Pg.313]    [Pg.244]    [Pg.493]    [Pg.23]    [Pg.2]    [Pg.185]    [Pg.296]    [Pg.583]    [Pg.27]    [Pg.129]    [Pg.116]    [Pg.493]    [Pg.583]    [Pg.380]    [Pg.584]    [Pg.50]    [Pg.12]    [Pg.282]    [Pg.282]    [Pg.284]    [Pg.25]    [Pg.202]    [Pg.114]    [Pg.89]    [Pg.83]    [Pg.143]   
See also in sourсe #XX -- [ Pg.313 , Pg.314 ]