Attenuated Total Reflection crystal

Haupt and co-workers have created a novel flow injection sensor by applying their 2,4-D MIP (see Section 20.2.5.10.) to the surface of ZnSe attenuated total reflectance crystals [50], In this way, binding of the template could be monitored using FT-IR spectroscopy in the 3500-500 cm region. Three bulk MIPs were... [Pg.491]

Attenuated total reflection (ATR), also called internal reflection, is based on the phenomenon of total internal reflection. In ATR the infrared beam is directed into an infrared-transmitting crystal so that it strikes the crystal surface at less than the critical angle and undergoes total internal reflection. [Pg.199]

Fixed pathlength transmission flow-cells for aqueous solution analysis are easily clogged. Attenuated total reflectance (ATR) provides an alternative method for aqueous solution analysis that avoids this problem. Sabo et al. [493] have reported the first application of an ATR flow-cell for both NPLC and RPLC-FUR. In micro-ATR-IR spectroscopy coupled to HPLC, the trapped effluent of the HPLC separation is added dropwise to the ATR crystal, where the chromatographic solvent is evaporated and the sample is enriched relative to the solution [494], Detection limits are not optimal. The ATR flow-cell is clearly inferior to other interfaces. [Pg.491]

Internal reflectance (attenuated total reflectance ATR ). The internal reflectance or, more usually, attenuated total reflectance (ATR), technique depends on the total reflectance of an IR beam at the internal face of an IR-transparent crystal of high IR refractive index, as shown in Figure 2.38. Medium 1 is a prism of such a material (for example, Si, Ge or KRS-5 [thallous bromide- iodide]), medium 2 is a thin coating of a metal (Au, Pt, Fe) which forms the working electrode and medium 3 is the electrolyte. The... [Pg.96]

Recently, polyethylene and Teflon mesh sample holders have been used. A drop of sample is placed on the mesh and spread to a relatively uniform thickness for analysis. These holders can often be rinsed and reused. A very convenient alternative to liquid sample holders is the technique called attenuated total reflection or ATR. The ATR cell is a crystal of gallium arsenide, GaAs and the infrared radiation enters one end of the trapezoidal crystal. With the angles adjusted to obtain total internal reflection, all of the IR radiation passes through the crystal and exits the other end as shown in Fig. 5.14. [Pg.145]

An infrared spectrum is a plot of percent radiation absorbed versus the frequency of the incident radiation given in wavenumbers (cm ) or in wave length ( xm). A variation of this method, diffuse reflectance spectroscopy, is used for samples with poor transmittance, e.g. cubic hematite crystals. Increased resolution and sensitivity as well as more rapid collection of data is provided by Fourier-transform-IR (FTIR), which averages a large number of spectra. Another IR technique makes use of attenuated total reflectance FTIR (ATR-FTIR) often using a cylindrical internal reflectance cell (CIR) (e.g. Tejedor-Tejedor Anderson, 1986). ATR enables wet systems and adsorbing species to be studied in situ. [Pg.141]

Attenuated total reflection (ATR) is the most common reflectance measurement modahty. ATR spectra cannot be compared to absorption spectra. While the same peaks are observed, their relative intensities differ considerably. The absorbances depend on the angle of incidence, not on sample thickness, since the radiation penetrates only a few micrometers into the sample. The major advantage of ATR spectroscopy is ease of use with a wide variety of solid samples. The spectra are readily obtainable with a minimum of preparation Samples are simply pressed against the dense ATR crystal. Plastics, rubbers, packaging materials, pastes, powders, solids, and dosage forms such as tablets can all be handled directly in a similar way. [Pg.376]

Attenuated Total Reflection (ATR).4c A sample brought in contact with the totally reflecting surface of a high-refractive-index material (the ATR crystal), will, on IR irradiation, give an evanescent wave in the less dense medium that extends beyond the reflecting interface. This wave will be attenuated in regions of the IR spectrum where the sample absorbs energy. Observation of such waves constitute ATR measurements. Only the small amounts of beads necessary to cover the area of the ATR crystal are required. [Pg.222]

X-ray photoelectron spectroscopy (XPS) was used for elemental analysis of plasma-deposited polymer films. The photoelectron spectrometer (Physical Electronics, Model 548) was used with an X-ray source of Mg Ka (1253.6 eV). Fourier transform infrared (FTIR) spectra of plasma polymers deposited on the steel substrate were recorded on a Perkin-Elmer Model 1750 spectrophotometer using the attenuated total reflection (ATR) technique. The silane plasma-deposited steel sample was cut to match precisely the surface of the reflection element, which was a high refractive index KRS-5 crystal. [Pg.463]

Some important functional groups and their region of absorbance are highlighted. Cheddar cheese was scanned by pressing 0.5 g of cheese on a diamond attenuated total reflectance (ATR) crystal. Extracts was scanned by drying 10 pi of the extract on a zinc selenide ATR crystal. [Pg.198]

The most commonly used technique for obtaining a spectrum is the attenuated total reflectance (ATR) method in the multiple internal reflectance (MIR) mode. In this method, the infrared beam is passed into a special crystal of a selenide (KRS-5). The angle of incidence is such that the beam will bounce along the crystal. A sample of the polyurethane is placed hard up against the crystal. The infrared just penetrates into the material before it continues down the crystal. A number of internal bounces are obtained along the crystal. Up to 25 reflectances are obtained from a 2 mm crystal. Figure 9.8 illustrates the infrared path in an ATR cell. [Pg.190]

Attenuated total reflection (ATR) is sometimes used to measure the infrared spectra of catalysts inside a reactor. The infrared light is coupled into an ATR crystal, which can be either a flat plate (e.g., the wall of a reactor) or a cylindrical rod (surrounded by catalyst particles). The evanescent wave that protrudes outside the crystal when the infrared beam reflects on the inside of its surface is used for the measurement. A review of ATR in catalysis has been published by Biirgi and Baiker [11], and a catalytic cell to apply the method in situ inside a catalyst bed reported by Moser and co-workers [12]. An example of ATR is discussed later in this chapter. [Pg.225]


See other pages where Attenuated Total Reflection crystal is mentioned: [Pg.101]    [Pg.68]    [Pg.164]    [Pg.101]    [Pg.68]    [Pg.164]    [Pg.393]    [Pg.314]    [Pg.423]    [Pg.289]    [Pg.10]    [Pg.539]    [Pg.740]    [Pg.266]    [Pg.741]    [Pg.133]    [Pg.318]    [Pg.69]    [Pg.302]    [Pg.114]    [Pg.87]    [Pg.82]    [Pg.719]    [Pg.873]    [Pg.221]    [Pg.224]    [Pg.180]    [Pg.37]    [Pg.73]    [Pg.424]    [Pg.79]    [Pg.120]    [Pg.121]    [Pg.144]    [Pg.192]   


SEARCH



ATTENUATED TOTAL

Attenuated total reflectance

Attenuated total reflectance Attenuation

Attenuated total reflectance crystals

Attenuation total reflection

Attenuator attenuated total reflection

Reflection, attenuated total

Reflectivity total

Total reflection

© 2024 chempedia.info