Chromatographic solvents

For optimum mobile phase selection we have to consider certain chemical characteristics besides the solvent strength [15,16]. From this point of view, the chromatographic solvents can be divided as follows ... [Pg.84]

Lau, S. Y. M., Taneja, A. K., and Hodges, R. S., Effects of high-performance liquid chromatographic solvents and hydrophobic matrices on the secondary and quaternary structure of a model protein. Reversed-phase and size exclusion high-performance liquid chromatography, /. Chromatogr., 317, 129, 1984. [Pg.197]

Extraction or dissolution almost invariably will cause low-MW material in a polymer to be present to some extent in the solution to be chromatographed. Solvent peaks interfere especially in trace analysis solvent impurities also may interfere. For identification or determination of residual solvents in polymers it is mandatory to use solventless methods of analysis so as not to confuse solvents in which the sample is dissolved for analysis with residual solvents in the sample. Gas chromatographic methods for the analysis of some low-boiling substances in the manufacture of polyester polymers have been reviewed [129]. The contents of residual solvents (CH2C12, CgHsCI) and monomers (bisphenol A, dichlorodiphenyl sulfone) in commercial polycarbonates and polysulfones were determined. Also residual monomers in PVAc latices were analysed by GC methods [130]. GC was also... [Pg.195]

Fixed pathlength transmission flow-cells for aqueous solution analysis are easily clogged. Attenuated total reflectance (ATR) provides an alternative method for aqueous solution analysis that avoids this problem. Sabo et al. [493] have reported the first application of an ATR flow-cell for both NPLC and RPLC-FUR. In micro-ATR-IR spectroscopy coupled to HPLC, the trapped effluent of the HPLC separation is added dropwise to the ATR crystal, where the chromatographic solvent is evaporated and the sample is enriched relative to the solution [494], Detection limits are not optimal. The ATR flow-cell is clearly inferior to other interfaces. [Pg.491]

Burdo and Seitz reported in 1975 the mechanism of the formation of a cobalt peroxide complex as the important intermediate leading to luminescence in the cobalt catalysis of the luminol CL reaction [116]. Delumyea and Hartkopf reported metal catalysis of the luminol reaction in chromatographic solvent systems in 1976 [117], while Yurow and Sass [118] reported on the structure-CL correlation for various organic compounds in the luminol-peroxide reaction. [Pg.22]

P. Stepnowski, K.-H. Blotevogel, P. Ganczarek, U. Fischer and B. Jastorff, Total recycling of chromatographic solvents — applied management of methanol and acetonitrile waste. Resource Conserv. Recycl. 35 (2002) 163-175. [Pg.353]

DJ. Swinton and M.J. Wirth, Lateral diffusion of l,l -dioctadecyl-3,3,3, 3 -tetramethylindo-carbocyanine perchlorate at the interfaces of C-18 and chromatographic solvents. Anal. Chem., 72 (2000) 3725-3730. [Pg.569]

These maxima have been assigned to background absorption caused by chromatographic solvents which have not been entirely compensated for by the blank. [Pg.113]

HPLC-UV-NMR can now be considered to be a routine analytical technique for pharmaceutical mixture analysis and for many studies in the biomedical field. HPLC-UV-NMR-MS is becoming more routine with a considerable number of systems now installed worldwide, but the chromatographic solvent systems are limited to those compatible with both NMR spectroscopy and mass spectrometry. The increased use of HPLC-UV-IR-NMR-MS is possible, but it is unlikely to become widespread, and the solvent problems are more complex. The future holds the promise of new technical advances to improve efficiency, and to enhance routine operation. These approaches include the use of small-scale separations, such as capillary electrochromatography, greater automation, and higher sensitivity and lower NMR detection limits through the use of NMR detectors cooled to cryogenic temperatures. [Pg.84]


See other pages where Chromatographic solvents is mentioned: [Pg.400]    [Pg.287]    [Pg.361]    [Pg.15]    [Pg.131]    [Pg.257]    [Pg.338]    [Pg.61]    [Pg.364]    [Pg.97]    [Pg.301]    [Pg.264]    [Pg.267]    [Pg.268]    [Pg.268]    [Pg.212]    [Pg.189]    [Pg.96]    [Pg.96]    [Pg.123]    [Pg.123]    [Pg.20]    [Pg.4]    [Pg.51]    [Pg.122]   
See also in sourсe #XX -- [ Pg.11 , Pg.47 ]

See also in sourсe #XX -- [ Pg.3 ]




SEARCH



Chromatographic adsorption selection of solvents for

Chromatographic retention-solvent strength

Chromatographic solvents, properties

Helen F. Gleeson 4 Liquid Crystals as Solvents for Spectroscopic, Chemical Reaction, and Gas Chromatographic Applications

Of chromatographic solvents

Selection of Chromatographic Solvent

Size Exclusion Chromatographic (ISEC) Analysis of Solvent Wetted Polymer Supports

Size exclusion chromatograph solvents

Solvents of chromatographic interest

Viscosity of chromatographic solvents

© 2024 chempedia.info