Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atomic detection limits

Laser-excited atomic fluorescence spectrometry is capable of extremely low detection limits, particularly when combined with electrothermal atomization. Detection limits in the femtogram (10 g) to attogram (10 g) range have been shown for many elements. Commercial instrumentation has not been developed for laser-based AFS, probably because of its expense and the nonroutine nature of high-powered lasers. Atomic fluorescence has the disadvantage of being a singleelement method unless tunable lasers with their inherent complexities are used. [Pg.868]

The first commercial plasma atomic fluorescence spectrometer was developed by Demers and Allemand. Hollow cathode lamps are used as radiation sources and an inductively coupled plasma torch as an atomizer. Detection limits are reported for more than 30 elements. The linear dynamic range is normally 10 to 10. ... [Pg.211]

The choice between X-ray fluorescence and the two other methods will be guided by the concentration levels and by the duration of the analytical procedure X-ray fluorescence is usually less sensitive than atomic absorption, but, at least for petroleum products, it requires less preparation after obtaining the calibration curve. Table 2.4 shows the detectable limits and accuracies of the three methods given above for the most commonly analyzed metals in petroleum products. For atomic absorption and plasma, the figures are given for analysis in an organic medium without mineralization. [Pg.38]

The detection limits in the table correspond generally to the concentration of an element required to give a net signal equal to three times the standard deviation of the noise (background) in accordance with lUPAC recommendations. Detection limits can be confusing when steady-state techniques such as flame atomic emission or absorption, and plasma atomic emission or fluorescence, which... [Pg.717]

The section on Spectroscopy has been retained but with some revisions and expansion. The section includes ultraviolet-visible spectroscopy, fluorescence, infrared and Raman spectroscopy, and X-ray spectrometry. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon induction coupled plasma, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-19, and phosphoms-31. [Pg.1284]

Atomic Absorption Detection Limits for Selected Elements... [Pg.417]

Choice of Atomization and Excitation Source Except for the alkali metals, detection limits when using an ICP are significantly better than those obtained with flame emission (Table 10.14). Plasmas also are subject to fewer spectral and chemical interferences. For these reasons a plasma emission source is usually the better choice. [Pg.437]

Highly sensitive iastmmental techniques, such as x-ray fluorescence, atomic absorption spectrometry, and iaductively coupled plasma optical emission spectrometry, have wide appHcation for the analysis of silver ia a multitude of materials. In order to minimize the effects of various matrices ia which silver may exist, samples are treated with perchloric or nitric acid. Direct-aspiration atomic absorption (25) and iaductively coupled plasma (26) have silver detection limits of 10 and 7 l-lg/L, respectively. The use of a graphic furnace ia an atomic absorption spectrograph lowers the silver detection limit to 0.2 l-ig/L. [Pg.91]

Atomic Absorption/Emission Spectrometry. Atomic absorption or emission spectrometric methods are commonly used for inorganic elements in a variety of matrices. The general principles and appHcations have been reviewed (43). Flame-emission spectrometry allows detection at low levels (10 g). It has been claimed that flame methods give better reproducibiHty than electrical excitation methods, owing to better control of several variables involved in flame excitation. Detection limits for selected elements by flame-emission spectrometry given in Table 4. Inductively coupled plasma emission spectrometry may also be employed. [Pg.243]

Since 1970, new analytical techniques, eg, ion chromatography, have been developed, and others, eg, atomic absorption and emission, have been improved (1—5). Detection limits for many chemicals have been dramatically lowered. Many wet chemical methods have been automated and are controlled by microprocessors which allow greater data output in a shorter time. Perhaps the best known continuous-flow analy2er for water analysis is the Autoanaly2er system manufactured by Technicon Instmments Corp. (Tarrytown, N.Y.) (6). Isolation of samples is maintained by pumping air bubbles into the flow line. Recently, flow-injection analysis has also become popular, and a theoretical comparison of it with the segmented flow analy2er has been made (7—9). [Pg.230]

Atomic absorption spectroscopy is more suited to samples where the number of metals is small, because it is essentially a single-element technique. The conventional air—acetylene flame is used for most metals however, elements that form refractory compounds, eg, Al, Si, V, etc, require the hotter nitrous oxide—acetylene flame. The use of a graphite furnace provides detection limits much lower than either of the flames. A cold-vapor-generation technique combined with atomic absorption is considered the most suitable method for mercury analysis (34). [Pg.232]

Atomic absorption spectroscopy is an alternative to the colorimetric method. Arsine is stiU generated but is purged into a heated open-end tube furnace or an argon—hydrogen flame for atomi2ation of the arsenic and measurement. Arsenic can also be measured by direct sample injection into the graphite furnace. The detection limit with the air—acetylene flame is too high to be useful for most water analysis. [Pg.232]

Because of the increasing emphasis on monitoring of environmental cadmium the detemiination of extremely low concentrations of cadmium ion has been developed. Table 2 Hsts the most prevalent analytical techniques and the detection limits. In general, for soluble cadmium species, atomic absorption is the method of choice for detection of very low concentrations. Mobile prompt gamma in vivo activation analysis has been developed for the nondestmctive sampling of cadmium in biological samples (18). [Pg.393]


See other pages where Atomic detection limits is mentioned: [Pg.2]    [Pg.478]    [Pg.134]    [Pg.2]    [Pg.478]    [Pg.134]    [Pg.799]    [Pg.1625]    [Pg.48]    [Pg.415]    [Pg.416]    [Pg.570]    [Pg.356]    [Pg.276]    [Pg.524]    [Pg.442]    [Pg.171]    [Pg.394]    [Pg.319]    [Pg.320]    [Pg.321]    [Pg.321]    [Pg.134]    [Pg.250]    [Pg.393]    [Pg.410]    [Pg.410]    [Pg.69]    [Pg.71]    [Pg.88]    [Pg.160]   
See also in sourсe #XX -- [ Pg.55 ]

See also in sourсe #XX -- [ Pg.250 , Pg.252 ]

See also in sourсe #XX -- [ Pg.672 ]




SEARCH



Atomic absorption detection limits

Atomic absorption electrothermal, detection limits

Atomic absorption spectrometry detection limits

Atomic absorption spectrophotometry detection limits

Atomic absorption spectroscopy detection limit

Atomic emission detection limits

Atomic emission spectrometry detection limits

Atomic fluorescence, detection limits intensity

Atomic limit

Atomic optical spectrometry detection limits

Detectable limit

Detection atomic

Detection limits

Detection limits atomic fluorescence

Detection limits atomic optical

Detection limits atomic spectroscopy

Detection limits, limitations

Detection-limiting

Electrothermal atomizer detection limits

Flame atomic absorption, detection limits

© 2024 chempedia.info