Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Assay complexity

Wash out unbound secondary antibodies and assay complexes. [Pg.125]

Figure 3 Assay complexity versus correlation with human absorption. Data from both complex biological and artificial permeation assays can provide valuable information regarding the absorption of a drug. Source. Courtesy of Millipore Corporation, Billerica, Massachusetts, U.S.A. Figure 3 Assay complexity versus correlation with human absorption. Data from both complex biological and artificial permeation assays can provide valuable information regarding the absorption of a drug. Source. Courtesy of Millipore Corporation, Billerica, Massachusetts, U.S.A.
Figure 5.3 Assay complexity versus correlation with human absorption. Figure 5.3 Assay complexity versus correlation with human absorption.
Shea [41] developed a method that separated the toxins with micellar electrokinetic capillary chromatography, followed by detection with laser-induced fluorescence. This method was sufQ-ciently sensitive to follow food chain transfer of toxins from K. brevis cells in culture to planktivo-rous copepods and from the copepods to linlish [42], However, the requirements for derivatization of the sample and assay complexity again worked against common acceptance of this method. [Pg.555]

Immunoassays are analytical methods that achieve the detection and quantitation of analytes in biological or environmental samples through the formation of a stable complex between the analyte and a specific antibody. By labeling the analyte or the antibody, or another constituent of the assay, complex formation results in a measurable change in the distribution and/or activity of the label, allowing very... [Pg.2118]

This experiment describes the adaptation of the bicinchoninic acid (BCA) protein assay to a flow injection analysis. The assay is based on the reduction of Cu + to Cu+ by the protein, followed by the reaction of Cu+ with bicinchoninic acid to form a purple complex that absorbs at 562 nm. Directions are provided for the analysis of bovine serum albumin and rabbit immunoglobulin G, and suggestions are provided for additional analyses. [Pg.660]

Hydantoin itself can be detected ia small concentrations ia the presence of other NH-containing compounds by paper chromatography followed by detection with a mercury acetate—diphenylcarba2one spray reagent. A variety of analytical reactions has been developed for 5,5-disubstituted hydantoias, due to their medicinal iaterest. These reactions are best exemplified by reference to the assays used for 5,5-diphenylhydantoiQ (73—78), most of which are based on their cycHc ureide stmcture. Identity tests iaclude the foUowiag (/) the Zwikker reaction, consisting of the formation of a colored complex on treatment with cobalt(II) salts ia the presence of an amine (2) formation of colored copper complexes and (3) precipitation on addition of silver(I) species, due to formation of iasoluble salts at N. ... [Pg.255]

Most modem RJAs utilize a competitive assay format (Fig. 2) in which radiolabled antigen, Ag, competes with unlabeled antigen, Ag, in a sample for binding to the antibody. Ah. The free antigens are then separated from the antigen—antibody complexes, and the amount of radioactivity in the... [Pg.23]

EIAs can be used per se or with a spectrophotometer. Traditionally, EIAs have been developed in 96-weU microtiter plates which provide the immobilization support for the assay, the reaction vessel, and, when linked to a spectrophotometer-based reader, a rapid means to detect and quantify the color resulting from interaction of a substrate with the antibody—antigen—enzyme complex. Automated immunoassay analyzers targeted primarily for use in the clinical laboratory have taken automation one step further, utilizing robotics to carry out all reagent additions, washings, and final quantification including report preparation. [Pg.24]

Polymers and Coatings Advances ia polymer chemistry have resulted ia many successful medical devices, including diagnostic assays (26). Polymers (qv), which can be manufactured ia a wide range of compositions, ate used to enhance speed, sensitivity, and versatiUty of both biosensors and dry chemistry systems to measure vital analytes. Their properties can be regulated by composition variations and modifications. Furthermore, polymers can be configured iato simple to complex shapes. [Pg.42]

The hberated iodine, as the complex triiodide ion, may be titrated with standard thiosulfate solution. A general iodometric assay method for organic peroxides has been pubUshed (253). Some peroxyesters may be determined by ferric ion-catalyzed iodometric analysis or by cupric ion catalysis. The latter has become an ASTM Standard procedure (254). Other reducing agents are ferrous, titanous, chromous, staimous, and arsenite ions triphenylphosphine diphenyl sulfide and triphenjiarsine (255,256). [Pg.132]

Analytical Techniques. Sorbic acid and potassium sorbate are assayed titrimetricaHy (51). The quantitative analysis of sorbic acid in food or beverages, which may require solvent extraction or steam distillation (52,53), employs various techniques. The two classical methods are both spectrophotometric (54—56). In the ultraviolet method, the prepared sample is acidified and the sorbic acid is measured at 250 260 nm. In the colorimetric method, the sorbic acid in the prepared sample is oxidized and then reacts with thiobarbituric acid the complex is measured at - 530 nm. Chromatographic techniques are also used for the analysis of sorbic acid. High pressure Hquid chromatography with ultraviolet detection is used to separate and quantify sorbic acid from other ultraviolet-absorbing species (57—59). Sorbic acid in food extracts is deterrnined by gas chromatography with flame ionization detection (60—62). [Pg.284]

The dehydrogenation of the mixture of m- and -ethyltoluenes is similar to that of ethylbenzene, but more dilution steam is required to prevent rapid coking on the catalyst. The recovery and purification of vinyltoluene monomer is considerably more difficult than for styrene owing to the high boiling point and high rate of thermal polymerization of the former and the complexity of the reactor effluent, which contains a large number of by-products. Pressures as low as 2.7 kPa (20 mm Hg) are used to keep distillation temperatures low even in the presence of polymerization inhibitor. The finished vinyltoluene monomer typically has an assay of 99.6%. [Pg.489]

ThioglycoHc acid can be identified by its in spectmm or by gas chromatography. Most of the by-products and self-esterification products are also detected by liquid chromatography, eg, thiodiglycolic acid, dithiodiglycolic acid, linear dimers, and polymers. Iron content can be assayed by the red sensitive complex of 1,10-phenanthroline [66-71-7] and ferrous ion of a mineralised sample. Ferric ion turns an aqueous ammonia solution deep red-violet. [Pg.4]

Spectroscopic methods such as uv and fluorescence have rehed on the polyene chromophore of vitamin A as a basis for analysis. Indirectly, the classical Carr-Price colorimetric test also exploits this feature and measures the amount of a transient blue complex at 620 nm which is formed when vitamin A is dehydrated in the presence of Lewis acids. For uv measurements of retinol, retinyl acetate, and retinyl palmitate, analysis is done at 325 nm. More sensitive measurements can be obtained by fluorescence. Excitation is done at 325 nm and emission at 470 nm. Although useful, all of these methods suffer from the fact that the method is not specific and any compound which has spectral characteristics similar to vitamin A will assay like the vitamin... [Pg.102]

Assay of beryUium metal and beryUium compounds is usuaUy accompHshed by titration. The sample is dissolved in sulfuric acid. Solution pH is adjusted to 8.5 using sodium hydroxide. The beryUium hydroxide precipitate is redissolved by addition of excess sodium fluoride. Liberated hydroxide is titrated with sulfuric acid. The beryUium content of the sample is calculated from the titration volume. Standards containing known beryUium concentrations must be analyzed along with the samples, as complexation of beryUium by fluoride is not quantitative. Titration rate and hold times ate critical therefore use of an automatic titrator is recommended. Other fluotide-complexing elements such as aluminum, sUicon, zirconium, hafnium, uranium, thorium, and rate earth elements must be absent, or must be corrected for if present in smaU amounts. Copper-beryUium and nickel—beryUium aUoys can be analyzed by titration if the beryUium is first separated from copper, nickel, and cobalt by ammonium hydroxide precipitation (15,16). [Pg.68]

Hplc techniques are used to routinely separate and quantify less volatile compounds. The hplc columns used to affect this separation are selected based on the constituents of interest. They are typically reverse phase or anion exchange in nature. The constituents routinely assayed in this type of analysis are those high in molecular weight or low in volatility. Specific compounds of interest include wood sugars, vanillin, and tannin complexes. The most common types of hplc detectors employed in the analysis of distilled spirits are the refractive index detector and the ultraviolet detector. Additionally, the recent introduction of the photodiode array detector is making a significant impact in the analysis of distilled spirits. [Pg.89]


See other pages where Assay complexity is mentioned: [Pg.179]    [Pg.347]    [Pg.211]    [Pg.124]    [Pg.104]    [Pg.272]    [Pg.68]    [Pg.555]    [Pg.273]    [Pg.326]    [Pg.179]    [Pg.347]    [Pg.211]    [Pg.124]    [Pg.104]    [Pg.272]    [Pg.68]    [Pg.555]    [Pg.273]    [Pg.326]    [Pg.142]    [Pg.198]    [Pg.21]    [Pg.22]    [Pg.23]    [Pg.23]    [Pg.24]    [Pg.26]    [Pg.27]    [Pg.28]    [Pg.28]    [Pg.395]    [Pg.132]    [Pg.240]    [Pg.484]    [Pg.52]    [Pg.52]    [Pg.284]    [Pg.114]    [Pg.101]    [Pg.110]    [Pg.110]    [Pg.111]   


SEARCH



Analysis of Azides for Assay, and in Complex Media

Biological assays copper complexation

Colorimetric assays involving complexation reactions

Enzyme-linked immunosorbent assay antigen-antibody complexes

Immune Complex Assays

Metal complexing assays

© 2024 chempedia.info