Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data, application

Table 4. Manufacture, Production, and Application Data for Selected Aminonaphthalenesulfonic Acids... Table 4. Manufacture, Production, and Application Data for Selected Aminonaphthalenesulfonic Acids...
Application Data Sheet—Standard Designationsfor Wrought and Cast Copper and Copper Alloys, Copper Development Association, Greenwich, Conn., 1992. [Pg.237]

Application. Data were collected on the cooling of water in the atmosphere as a function of time. [Pg.504]

In the absence of more direc tly applicable data, the flexibility factor k and stress-intensification factor i shown in Table 10-54 may be used in flexibihty calculations in Eq. (10-101). For piping components or attachments (such as valves, strainers, anchor rings, and bands) not covered in the table, suitable stress-intensification factors may be assumed by comparison of their significant geometry with that of the components shown. [Pg.995]

Data may be inaccurate, incomplete, or inappropriate Data from related activities might not be directly applicable Data generated by expert Judgment may be inaccurate Improper or incomplete chmacterization of the general population... [Pg.524]

The pressure drops for these units are typically low, ranging from 0.2 to 10-15 psi. The woven wire mesh runs even lower in pressure drops for the same or larger flow rates. Consult the manufacturers for specific application data. [Pg.280]

This concept has not gained commercial popularity due to the proprietary nature of the Fractionation Research, Inc. (FRI) data being limited to member organizations, and the public literature does not contain much independent research and application data. General industrial and commercial proprietary designs available are listed in Table 8-12, but may not be all-inclusive ... [Pg.122]

In some instances it may be possible, though it is usually very difficult, to undertake laboratory corrosion tests under conditions that will be the same as those encountered in some practical application, and thus to secure some directly applicable data. More often, the conditions of service are so variable or so difficult to appraise accurately and duplicate in the laboratory that it is impractical and probably unwise to attempt to do so. A better procedure is to examine the individual effects of the several controlling factors by varying them one at a time so as to provide a picture of their influence on the... [Pg.992]

Comprehensive application data should be made available for all marketed packaged units, to allow designers or sales engineers to make the correct selections for their purposes. However, it should be borne in mind that manufacturers or sales outlets are frequently not aware of all the parameters of an installation, and the interpretation of catalogue data has many pitfalls. [Pg.159]

Calculations of this sort are only of importance to the tower designer. Manufacturers application data will give the cooling range or capacity in terms of wet bulb, inlet water temperature and mass flow [16, 19]. [Pg.262]

Manufacturers will publish rating and application data for their products, based on standard test conditions and for the more usual range of uses. They cannot be expected to have accurate figures for every possible combination of conditions for an individual purpose, although most will produce estimates if asked. [Pg.357]

Many successful projects have shown that application information can be divided into the following four categories Terminology, Special Characteristics, Abstract Functions, and Graphics. Although these categories are the basis for the searchable application data base, each project requires a conceptual phase to define how to focus. [Pg.606]

PCT application data from the World Intellectual Property Office... [Pg.623]

The websites of manufacturers of LC-MS equipment are often a valuable source of applications data and educational material, as well as details of their own products ... [Pg.301]

Based on all application data, the results of this study indicate a linear relationship between the increase of the dislodgeable foliar residue and application rate however, for the low-volume applications, this relationship is not statistically significant. The relatively limited number of data may be the reason for this. [Pg.133]

The automated pesticide runoff model consists of a set of FORTRAN programs which calculate the amount of pesticide runoff from input of river basin data, rainfall data, pesticide characteristics, and application data. Table I shows the input requirements for the SWRRB model. Table II shows the output data from the SWRBB model. [Pg.251]

Figure 3.4. Effects of phosphate levels on Cd and Zn solution speciation in California soils that received sludge application (data extracted from Villarroel et al., 1993)... Figure 3.4. Effects of phosphate levels on Cd and Zn solution speciation in California soils that received sludge application (data extracted from Villarroel et al., 1993)...
Figure 7.5. The AB-DTPA-extractable Cu and Zn in a semi-arid soil from Colorado after termination of five excessive biosolids applications. Open circle (fine, smectitic, mesic Aridic Argiustolls) and open triangle (fine, smectitic, mesic Aridic Paleustolls) represent control soil without biosolid application, while solid circle and solid triangle indicate biosolid applications (data extracted from Barbarick ad Ippolito, 2003)... Figure 7.5. The AB-DTPA-extractable Cu and Zn in a semi-arid soil from Colorado after termination of five excessive biosolids applications. Open circle (fine, smectitic, mesic Aridic Argiustolls) and open triangle (fine, smectitic, mesic Aridic Paleustolls) represent control soil without biosolid application, while solid circle and solid triangle indicate biosolid applications (data extracted from Barbarick ad Ippolito, 2003)...
The model was forced with agricultural application data of the insecticide DDT compiled by Semeena and Lammel (2003). Statistical data of DDT consumption reported by member of the UN states to Food and Agriculture Organisation (FAO) were combined with other published data (details in Semeena and Lammel (2003)). The emission inventory assumed 100 % of p,p -DDT. After scaling the DDT consumption with crop land distribution, the data were extrapolated to the model grid. The result was a data set with spatially and temporally varying applications (accumulated application and temporal evolution shown in Figure 3.1). No seasonal or diurnal variation of the applications is considered. [Pg.50]

The weld joint strength reduction factor is the ratio of the nominal stress to cause failure of the weld joint to that of the base material for the same duration. In the absence of more applicable data (e.g., creep testing), the factor shall be taken as 1.0 at temperatures equal or colder than 510°C (950°F), and 0.5 at 815°C (1,500°F) for all materials. The strength reduction factor shall be linearly interpolated for intermediate temperatures. The designer is responsible for determining weld joint strength reduction factors for temperatures warmer than 815°C (1,500°F). [Pg.91]

IP-2.2.7(d). The strength reduction factor represents the reduction in yield strength with long-term exposure of the material to elevated temperatures and, in the absence of more applicable data, shall be taken as 1.0 for austenitic stainless steel and 0.8 for other materials. For castings, the basic allowable stress shall be multiplied by the casting quality factor, Ec. Where the allowable stress value exceeds two-thirds of yield strength at temperature, the allowable stress value must be reduced as specified in para. IP-2.2.7(c). Wind and earthquake forces need not be considered as acting concurrently. At temperatures warmer than 427°C (800°F), use 1.33... [Pg.91]

Data from 6 months of administration in nonrodents should be available before the initiation of clinical trials longer than 3 months. Alternatively, if applicable, data from a 9-month nonrodent study should be available before the treatment duration exceeds that which is supported by the available toxicity studies. dTo support Phase I and II Trials in the EU AND Phase I, II and III Trials in the U.S. and Japan. [Pg.58]

Complex flavour analysis with the ion trap detector. Finnigan MAT Application Data Sheet ADS 7. [Pg.117]


See other pages where Data, application is mentioned: [Pg.125]    [Pg.140]    [Pg.45]    [Pg.186]    [Pg.276]    [Pg.323]    [Pg.767]    [Pg.768]    [Pg.159]    [Pg.594]    [Pg.276]    [Pg.123]    [Pg.973]    [Pg.819]    [Pg.140]    [Pg.81]    [Pg.384]    [Pg.288]    [Pg.244]    [Pg.295]    [Pg.239]   
See also in sourсe #XX -- [ Pg.357 ]

See also in sourсe #XX -- [ Pg.352 ]




SEARCH



© 2024 chempedia.info