The Iodometric method has also been utilized in analyzing hydrogen sulfide in the air (EPA 1978). The method is based on the oxidation of hydrogen sulfide by absorption of the gas sample in an impinger containing a standardized solution of iodine and potassium iodide. This solution will also oxidize sulfur dioxide. The Iodometric method is suitable for occupational settings. The accuracy of the method is approximately 0.50 ppm hydrogen sulfide for a 30-L air sample (EPA 1978). [Pg.163]

There are two major experimental techniques that can be used to analyze hydrogen bonding in noncrystalline polymer systems. The first is based on thermodynamic measurements which can be related to molecular properties by using statistical mechanics. The second, and much more powerful, way to elucidate the presence and nature of hydrogen bonds in amorphous polymers is by using spectroscopy (Coleman et al., 1991). From the present repertoire of spectroscopic techniques which includes IR, Raman, electronic absorption, fluorescence, and magnetic resonance spectroscopy, the IR is by far the most sensitive to the presence of hydrogen bonds (Coleman et al., 1991). [Pg.97]

The most widely used sensor for chloride ions in clinical analyzers is based on an ion-exchanger, a quaternary alkylammonium chloride, dispersed in a plastic membrane. It is not an ideal sensor due to the interference of lipophilic anions (e.g., salicylates, bromides) and lip-ophylic cations (e.g., bacteriostatic agents, anesthetics) and a relatively poor selectivity towards hydrogen carbonates (bicarbonates). However, compared to charged anion- and neutral carrier-based membranes that have been tested, it is still the best-suited for automated analyzers. [Pg.16]

The CHNS and O analyzer offers speed, precision, and ease of use for the compositional analysis of solid or liquid materials. This analyzer is based on the classical organic analysis Pregl-Dumas technique and provides important information to the scientist regarding product compositional chemistry. This analyzer offers the user multiple analysis options, including carbon, hydrogen, nitrogen, sulfur, and oxygen (CHN or CHNS and O2 analysis). The user may choose one or more options to suit the needs of the labora-... [Pg.46]

In this experiment the overall variance for the analysis of potassium hydrogen phthalate (KHP) in a mixture of KHP and sucrose is partitioned into that due to sampling and that due to the analytical method (an acid-base titration). By having individuals analyze samples with different % w/w KHP, the relationship between sampling error and concentration of analyte can be explored. [Pg.225]

The earliest examples of analytical methods based on chemical kinetics, which date from the late nineteenth century, took advantage of the catalytic activity of enzymes. Typically, the enzyme was added to a solution containing a suitable substrate, and the reaction between the two was monitored for a fixed time. The enzyme s activity was determined by measuring the amount of substrate that had reacted. Enzymes also were used in procedures for the quantitative analysis of hydrogen peroxide and carbohydrates. The application of catalytic reactions continued in the first half of the twentieth century, and developments included the use of nonenzymatic catalysts, noncatalytic reactions, and differences in reaction rates when analyzing samples with several analytes. [Pg.623]

More specifically, 2-aminophenol can be detected in solution using an iron(II) sulfate—hydrogen peroxide reagent (94). 3- Aminopheno1 has been analyzed colorimetrically by oxidation in base and subsequent extraction of a violet quinoneimide dye (95). A colorimetric method using... [Pg.312]

Effects of Cold Gas Recycle and Approach to Equilibrium. Product gases resulting from various CGR ratios were analyzed (Table XI). For the experiments tabulated, a decrease in the cold recycle ratio resulted consistently in increases in the product gas concentrations of water vapor, hydrogen, and carbon dioxide and a decrease in methane concentration. These trends may be noted in experiment HGR-12 as the CGR ratio decreased from 8.7 1 to 1.2 1, in experiment HGR-13 as it increased from 1.0 1 to 9.1 1, and in experiment HGR-14 as it decreased from 3.0 1 to 1.0 1. These trends indicate that the water-gas shift reaction (CO + H20 —> C02 + H2) was sustained to some degree. Except for the 462-hr period in experiment HGR-14, the apparent mass action constants for the water-gas shift reaction (based on the product gas compositions in Table XI) remained fairly constant at 0.57-1.6. These values are much lower than the value of 11.7 for equilibrium conversion at 400°C. In... [Pg.118]

The alkyl chain distribution of the base alcohol in alcohol sulfates is easily determined by gas chromatography. However, alcohol sulfates and alcohol ether sulfates are not volatile and require a previous hydrolysis to yield the free alcohol. The extracted free alcohol can be injected directly [306] or converted to its trimethylsilyl derivative before injection [307]. Alternatively, the alcohol sulfate can be decomposed by hydroiodic acid to yield the alkyl iodides of the starting alcohols [308]. A preferred method forms the alkyl iodides after hydrolysis of the alcohol sulfate which are analyzed after further extraction of the free alcohol, thus avoiding the formation of hydrogen sulfide. This latter method is commonly used to determine the alkyl chain distribution of alcohol ether sulfates. [Pg.285]

Little work has been carried out using electrochemical cells to analyze for impurities. Thermodynamic data have been measured for the interaction of nuclear fuels with liquid potassium using cells based on ThOj-YjOj electrolytes, so such cells could be used to monitor oxygen. Both the diffusion and electrochemical types of hydrogen and carbon meters should function satisfactorily in liquid potassium. [Pg.346]

Ishiyama et al. (1987) estimated hydrogen and oxygen isotopic compositions of ore fluid responsible for the base metal vein-type deposits in Jokoku-Katsuraoka area, southwestern part of the province. Estimated 5 0 and 5D values range from —49%o to —88%o and from —11.6%o to - -5.5%o, respectively. Hattori and Sakai (1979) analyzed inclusion fluids from the Chitose Au-Ag vein-type deposits and indicated that 8D and 5 0 for the ore fluids are —65%c to —75%o and —4.8%o to —6.2%c, respectively. [Pg.211]


See other pages where Analyzer hydrogen-based is mentioned: [Pg.10]    [Pg.447]    [Pg.8]    [Pg.189]    [Pg.198]    [Pg.10]    [Pg.8]    [Pg.634]    [Pg.634]    [Pg.671]    [Pg.131]    [Pg.21]    [Pg.38]    [Pg.228]    [Pg.44]    [Pg.41]    [Pg.1935]    [Pg.91]    [Pg.15]    [Pg.107]    [Pg.27]    [Pg.157]    [Pg.348]    [Pg.80]    [Pg.439]    [Pg.241]    [Pg.273]    [Pg.44]    [Pg.316]    [Pg.416]    [Pg.175]    [Pg.168]    [Pg.172]    [Pg.148]    [Pg.269]   