Analytical spectrophotometer

Analytical instruments and techniques are employed in food technology. Certain analytical spectrophotometers are designed to measure percent absorbance at selected wavelengths. A procedure for color analysis may... [Pg.974]

The use of non-zero water (e.g., LNSW) as ZW and for standard preparation requires determination of the nutrient content of the respective matrix and a determination of reagent blanks. Reagents in nutrient analysis do not absorb at the analytical spectrophotometer wavelength unless contaminated or old. Thus, a reagent blank is mostly caused by traces of the corresponding nutrient contained in chemicals or in the pure water. [Pg.225]

Atomization The most important difference between a spectrophotometer for atomic absorption and one for molecular absorption is the need to convert the analyte into a free atom. The process of converting an analyte in solid, liquid, or solution form to a free gaseous atom is called atomization. In most cases the sample containing the analyte undergoes some form of sample preparation that leaves the analyte in an organic or aqueous solution. For this reason, only the introduction of solution samples is considered in this text. Two general methods of atomization are used flame atomization and electrothermal atomization. A few elements are atomized using other methods. [Pg.412]

This is primarily engaged in analysis of boiler water treatment matters and involves on-site studies of various problems and the chemical examination of corrosion products, boiler scales, etc. It can also carry out certain types of metallurgical, fuel and inorganic analysis. Normal wet methods of analysis coupled with a visible ultraviolet and atomic absorption spectrophotometer are used for a wide range of analytical applications. Equipment in use by the engineering insurers providing these services can include an ion chromatograph, spectrometer equipment, atomic... [Pg.148]

The methods dependent upon measurement of an electrical property, and those based upon determination of the extent to which radiation is absorbed or upon assessment of the intensity of emitted radiation, all require the use of a suitable instrument, e.g. polarograph, spectrophotometer, etc., and in consequence such methods are referred to as instrumental methods . Instrumental methods are usually much faster than purely chemical procedures, they are normally applicable at concentrations far too small to be amenable to determination by classical methods, and they find wide application in industry. In most cases a microcomputer can be interfaced to the instrument so that absorption curves, polarograms, titration curves, etc., can be plotted automatically, and in fact, by the incorporation of appropriate servo-mechanisms, the whole analytical process may, in suitable cases, be completely automated. [Pg.8]

The comparison of more than two means is a situation that often arises in analytical chemistry. It may be useful, for example, to compare (a) the mean results obtained from different spectrophotometers all using the same analytical sample (b) the performance of a number of analysts using the same titration method. In the latter example assume that three analysts, using the same solutions, each perform four replicate titrations. In this case there are two possible sources of error (a) the random error associated with replicate measurements and (b) the variation that may arise between the individual analysts. These variations may be calculated and their effects estimated by a statistical method known as the Analysis of Variance (ANOVA), where the... [Pg.146]

Procedure. Weigh out 0.0226 g of hydrated ammonium iron(III) sulphate and dissolve it in 1 L of water in a graduated flask 50 mL of this solution contain 100 g of iron. Place 50.0 mL of the solution in a 100 mL separatory funnel, add 10 mL of a 1 per cent oxine (analytical grade) solution in chloroform and shake for 1 minute. Separate the chloroform layer. Transfer a portion of the latter to a 1.0 cm absorption cell. Determine the absorbance at 470 nm in a spectrophotometer, using the solvent as a blank or reference. Repeat the extraction with a further 10 mL of 1 per cent oxine solution in chloroform, and measure the absorbance to confirm that all the iron was extracted. [Pg.178]

All infrared spectrophotometers are provided with chart recorders which will present the complete infrared spectrum on a single continuous sheet, usually with wavelength and wavenumber scales shown for the abscissa and with absorbance and percentage transmittance as the ordinates. More advanced instruments also possess visual display units on which the spectra can be displayed as they are recorded and on which they can be compared with earlier spectra previously obtained or with spectra drawn from an extensive library held in a computer memory. These modern developments have all led to quantitative infrared spectrophotometry being a much more viable and useful analytical procedure than it was just a few years ago. [Pg.747]

Most educational laboratories keep their analytical balances in separate rooms, which are locked when not in use. Balances less than three feet apart are crowded, so sufficient space must be allowed. Such rooms will also be useful for other instruments, such as spectrophotometers, that do not give off heat or fumes. [Pg.10]

UV spectroscopy can be used to detect low levels of organic corrosion inhibitors in produced water. An analytic method has been developed using a diode array UV spectrophotometer [630]. [Pg.87]

Once the analyte has been separated from the matrix in LC, the best approach to the detection of the molecule must be determined. This section will discuss the detection techniques of ultraviolet/visible (UVA IS), fluorescence (FL), and electrochemical (EC) detection, with MS being addressed separately in Section 4.2. When deciding on the most appropriate detector for an LC separation, the appropriate chemical data on the analyte should be collected by using a spectrophotometer, fluorimeter, and potentiometer. [Pg.313]

Membrane separation coupled on-line to a flow-injection system was employed for the monitoring of propazine and terbutryn in natural water. A microporous hydro-phobic membrane was utilized in which the analytes were extracted from the aqueous medium into an organic solvent that was carried to the flow cell of a photodiode-array spectrophotometer. The LCDs were 4-5 qg so the technique could potentially be used for screening purposes. Samples with positive detection would require further analysis. [Pg.427]

The ultraviolet-visible spectrophotometer is the most widely used detector for HPLC. The basis of UV-VIS detection is the difference in the absorbance of light by the analyte and the solvent. A number of functional groups absorb... [Pg.14]

Spectral interferences may arise from the close proximity of other emission lines or bands to the analyte line or by overlap with it. They can often be eliminated or minimized by increasing the resolution of the instrumentation, e.g. changing from a filter photometer to a grating spectrophotometer. Alternatively, another analyte line can be selected for measurements. Correction for background emission is also important and is made by monitoring the emission from a blank solution at the wavelength of the analyte line or by averaging measurements made close to the line and on either side of it. [Pg.318]


See other pages where Analytical spectrophotometer is mentioned: [Pg.28]    [Pg.29]    [Pg.31]    [Pg.33]    [Pg.28]    [Pg.29]    [Pg.31]    [Pg.33]    [Pg.414]    [Pg.455]    [Pg.584]    [Pg.445]    [Pg.280]    [Pg.24]    [Pg.28]    [Pg.512]    [Pg.397]    [Pg.317]    [Pg.128]    [Pg.704]    [Pg.203]    [Pg.142]    [Pg.498]    [Pg.14]    [Pg.280]    [Pg.67]    [Pg.313]    [Pg.716]    [Pg.323]    [Pg.259]    [Pg.305]    [Pg.307]    [Pg.313]    [Pg.450]    [Pg.278]    [Pg.8]    [Pg.459]    [Pg.249]    [Pg.108]    [Pg.156]    [Pg.205]   