Analytical methods concentration

Knowledge of sulfur content in petroleum products is imperative the analytical methods are numerous and depend on both the concentration being measured and the material being analyzed. [Pg.31]

Typically, PIXE measurements are perfonned in a vacuum of around 10 Pa, although they can be perfonned in air with some limitations. Ion currents needed are typically a few nanoamperes and current is nonnally not a limiting factor in applying the teclmique with a particle accelerator. This beam current also nonnally leads to no significant damage to samples in the process of analysis, offering a non-destmctive analytical method sensitive to trace element concentration levels. [Pg.1843]

Normality is an older unit of concentration that, although once commonly used, is frequently ignored in today s laboratories. Normality is still used in some handbooks of analytical methods, and, for this reason, it is helpful to understand its meaning. For example, normality is the concentration unit used in Standard Methods for the Examination of Water and Wastewaterf a commonly used source of analytical methods for environmental laboratories. [Pg.16]

A certain concentration method works best when the analyte s concentration is approximately 10 ppb. [Pg.51]

Once the method is standardized, the analyte s concentration is given by... [Pg.116]

A calibration curve shows us the relationship between the measured signal and the analyte s concentration in a series of standards. The most useful calibration curve is a straight line since the method s sensitivity is the same for all concentrations of analyte. The equation for a linear calibration curve is... [Pg.118]

Even if a method is more selective for an interferent, it can be used to determine an analyte s concentration if the interferent s contribution to Sjamp is insignificant. The selectivity coefficient, Ka,i> was introduced in Chapter 3 as a means of characterizing a method s selectivity. [Pg.202]

In this experiment the overall variance for the analysis of potassium hydrogen phthalate (KHP) in a mixture of KHP and sucrose is partitioned into that due to sampling and that due to the analytical method (an acid-base titration). By having individuals analyze samples with different % w/w KHP, the relationship between sampling error and concentration of analyte can be explored. [Pg.225]

The following experiments introduce students to the importance of sample preparation and methods for extracting analytes from their matrix. Each experiment includes a brief description of the sample and analyte, as well as the method of analysis used to measure the analyte s concentration. [Pg.226]

The determination of an analyte s concentration based on its absorption of ultraviolet or visible radiation is one of the most frequently encountered quantitative analytical methods. One reason for its popularity is that many organic and inorganic compounds have strong absorption bands in the UV/Vis region of the electromagnetic spectrum. In addition, analytes that do not absorb UV/Vis radiation, or that absorb such radiation only weakly, frequently can be chemically coupled to a species that does. For example, nonabsorbing solutions of Pb + can be reacted with dithizone to form the red Pb-dithizonate complex. An additional advantage to UV/Vis absorption is that in most cases it is relatively easy to adjust experimental and instrumental conditions so that Beer s law is obeyed. [Pg.394]

Quantitative Analysis for a Single Analyte The concentration of a single analyte is determined by measuring the absorbance of the sample and applying Beer s law (equation 10.5) using any of the standardization methods described in Chapter 5. The most common methods are the normal calibration curve and the method of standard additions. Single-point standardizations also can be used, provided that the validity of Beer s law has been demonstrated. [Pg.400]

The generalized standard addition method (GSAM) extends the analysis of mixtures to situations in which matrix effects prevent the determination of 8x and 8y using external standards.When adding a known concentration of analyte to a solution containing an unknown concentration of analyte, the concentrations usually are not additive (see question 9 in Chapter 5). Conservation of mass, however, is always obeyed. Equation 10.11 can be written in terms of moles, n, by using the relationship... [Pg.402]

Since the junction potential is usually of unknown value, it is normally impossible to directly calculate the analyte s concentration using the Nernst equation. Quantitative analytical work is possible, however, using the standardization methods discussed in Chapter 5. [Pg.471]

The potentiometric determination of an analyte s concentration is one of the most common quantitative analytical techniques. Perhaps the most frequently employed, routine quantitative measurement is the potentiometric determination of a solution s pH, a technique considered in more detail in the following discussion. Other areas in which potentiometric applications are important include clinical chemistry, environmental chemistry, and potentiometric titrations. Before considering these applications, however, we must first examine more closely the relationship between cell potential and the analyte s concentration, as well as methods for standardizing potentiometric measurements. [Pg.485]

Environmental Applications Although ion-selective electrodes find use in environmental analysis, their application is not as widespread as in clinical analysis. Standard methods have been developed for the analysis of CN , F , NH3, and in water and wastewater. Except for F , however, other analytical methods are considered superior. By incorporating the ion-selective electrode into a flow cell, the continuous monitoring of wastewater streams and other flow systems is possible. Such applications are limited, however, by the electrode s response to the analyte s activity, rather than its concentration. Considerable interest has been shown in the development of biosensors for the field screening and monitoring of environmental samples for a number of priority pollutants. [Pg.494]

In potentiometry, the potential of an electrochemical cell under static conditions is used to determine an analyte s concentration. As seen in the preceding section, potentiometry is an important and frequently used quantitative method of analysis. Dynamic electrochemical methods, such as coulometry, voltammetry, and amper-ometry, in which current passes through the electrochemical cell, also are important analytical techniques. In this section we consider coulometric methods of analysis. Voltammetry and amperometry are covered in Section 1 ID. [Pg.496]

Thus, the limiting current, is a linear function of the concentration of O in bulk solution, and a quantitative analysis is possible using any of the standardization methods discussed in Chapter 5. Equations similar to equation 11.35 can be developed for other forms of voltammetry, in which peak currents are related to the analyte s concentration in bulk solution. [Pg.514]

Suppose we have a sample containing an analyte in a matrix that is incompatible with our analytical method. To determine the analyte s concentration we first separate it from the matrix using, for example, a liquid-liquid extraction. If there are additional analytes, we may need to use additional extractions to isolate them from the analyte s matrix. For a complex mixture of analytes this quickly becomes a tedious process. [Pg.544]

Adjusting the Analyte s Concentration Analytes present at concentrations too small to give an adequate signal need to be concentrated before analyzing. A side benefit of many of the extraction methods outlined earlier is that they often concentrate the analytes. Volatile organic materials isolated from aqueous samples by a purge and trap, for example, can be concentrated by as much as 1000-fold. [Pg.568]

Curve-Fitting Methods In the direct-computation methods discussed earlier, the analyte s concentration is determined by solving the appropriate rate equation at one or two discrete times. The relationship between the analyte s concentration and the measured response is a function of the rate constant, which must be measured in a separate experiment. This may be accomplished using a single external standard (as in Example 13.2) or with a calibration curve (as in Example 13.4). [Pg.631]

Sensitivity The sensitivity for a one-point fixed-time integral method of analysis is improved by making measurements under conditions in which the concentration of the monitored species is larger rather than smaller. When the analyte s concentration, or the concentration of any other reactant, is monitored, measurements are best made early in the reaction before its concentration has substantially decreased. On the other hand, when a product is used to monitor the reaction, measurements are more appropriately made at longer times. For a two-point fixed-time integral method, sensitivity is improved by increasing the difference between times t and f2. As discussed earlier, the sensitivity of a rate method improves when using the initial rate. [Pg.640]

Of the six parameters shown in Figure 13.18, the most important are peak height and return time. The peak height is related, directly or indirectly, to the analyte s concentration and is used for quantitative work. The sensitivity of the method, therefore, is also determined by the peak height. The return time determines the frequency with which samples maybe injected. Figure 13.19 shows that when a second sample is injected at a time T after injecting the first sample. [Pg.650]

Single-operator characteristics are determined by analyzing a sample whose concentration of analyte is known to the analyst. The second step in verifying a method is the blind analysis of standard samples where the analyte s concentration remains unknown to the analyst. The standard sample is analyzed several times, and the average concentration of the analyte is determined. This value should be within three, and preferably two standard deviations (as determined from the single-operator characteristics) of the analyte s known concentration. [Pg.683]

A final component of a quality control program is the certification of an analyst s competence to perform the analysis for which he or she is responsible. Before an analyst is allowed to perform a new analytical method, he or she may be required to successfully analyze an independent check sample with acceptable accuracy and precision. The check sample should be similar in composition to samples that the analyst will routinely encounter, with a concentration that is 5 to 50 times that of the method s detection limit. [Pg.708]

The concentration of aqueous solutions of the acid can be deterrnined by titration with sodium hydroxide, and the concentration of formate ion by oxidation with permanganate and back titration. Volatile impurities can be estimated by gas—Hquid chromatography. Standard analytical methods are detailed in References 37 and 38. [Pg.505]


See other pages where Analytical methods concentration is mentioned: [Pg.101]    [Pg.101]    [Pg.40]    [Pg.44]    [Pg.47]    [Pg.50]    [Pg.104]    [Pg.108]    [Pg.109]    [Pg.124]    [Pg.174]    [Pg.195]    [Pg.396]    [Pg.411]    [Pg.416]    [Pg.444]    [Pg.457]    [Pg.462]    [Pg.477]    [Pg.494]    [Pg.497]    [Pg.499]    [Pg.655]    [Pg.659]    [Pg.404]    [Pg.276]   