Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Actuators electric

Solenoid valve actuator Electric motor, AC A Atmospheric outlet FC Control element closes on failure of auxiliary energy supply FO Control element opens on failure of auxiliary energy supply O Silencer... [Pg.95]

Each independent and dependent operator has two aspects 1) Operation represents a component requiring actuation. For example, a motor-operated valve, is represented as a Type 6 operator since the valve needs both an input (flow) and an actuation (electric power) to pass the flow... [Pg.121]

The three biomimetic actuator models mentioned above are driven in a solution. The next target of the advanced model is an actuator electrically driven in air. A mechanical hand composed of two smart gel fingers working in... [Pg.160]

Device which actuates electric primers by using main voltage - in openpit and potash mining, for example. The switch can be located in a surface stand(shelter outside a mine) e.g. if the danger of gas outbursts exists. [Pg.89]

The main ancillary components that concur to reduce the gross stack power are reported in Fig. 4.10. The auxiliaries are actuated electrically, and the total DC power produced by stack is partially consumed by the motors that move the compressors and pumps, and by the electricity necessary to supply the radiator fan and the controller. [Pg.123]

Fire Suppression Actuation Electrical Emergency Mgmt Comm... [Pg.179]

Computer numerical control (CNC) means the digital control of machine tool units that consist of series of integrated mechanical actuators, electrical or electrohydraulic servomotors, power amplifiers, position and velocity sensors, and a dedicated computer running under a real-time operating system. [Pg.249]

All of the valves are available with air actuators, and some are available with electric actuators. Electric actuators are not usually used in process analysis applications because of both safety and reliability considerations. [Pg.3866]

As discussed in Section 10.2.3, PVP and DNA have been used to wrap and water-solublize SWNTs. For specific actuator, electrical and electro-optic applications, SWNTs have been wrapped by piezoelectric polyvinylidene fluoride and trifluor-oethylene copolymer [50] or with conjugated polymers [51, 52]. The conjugated polymer used to form a composite with MWNTs and an electron-transport layer in light-emitting diodes is poly(m-phenylene-vinylene-co-2,5-dioctyloxy-p-phenylene-vinylene) (PmPV) [53]. Wrapping coupled with electron doping has been achieved with polyethylene imine to form p-n junction devices ([40], see footnote 1). [Pg.196]

The rotary valves are two-position stainless-steel valves (Valeo Instruments, Inc.) with four to ten ports. The first two valves, 1 and 2 in Fig. 23-1, which are exposed to seawater, are made of Hastelloy C-22, a seawater resistant nickei-chromium-molybdenum alloy. The three valves in the heated zone (3, 4 and 5), if installed inside the GC oven, are equipped with high-temperature rotors, specified by the manufacturer (Valeo) to operate at temperatures up to 340 °C. AU valves can be actuated electrically for various degrees of automation. [Pg.506]

Fig. 6 Dimension of the polymer actuator. Electrical contact to the polymer is made at one end of the polymer film of length I (Adapted irom Madden et al. (2002a))... Fig. 6 Dimension of the polymer actuator. Electrical contact to the polymer is made at one end of the polymer film of length I (Adapted irom Madden et al. (2002a))...
In a recent study (Nguyen et al. 2014), starting with the diffusive impedance of a conducting polymer actuator, electrical, mechanical, and viscoelastic properties of a tri-layer conjugated polymer actuator are combined into an advanced mafliematical model, which describes the relationship between the eurvature of the actuator and an applied voltage, expressed as... [Pg.378]

Electrical timing devices may be used if the current frequency is controlled to an accuracy of 0.05 % or better. Alternating currents, as provided by some public power systems, are intermittently rather than continuously controlled. When used to actuate electrical timing devices, such control can cause large errors in kinematic viscosity flow time measurements. [Pg.128]


See other pages where Actuators electric is mentioned: [Pg.91]    [Pg.90]    [Pg.286]    [Pg.91]    [Pg.654]    [Pg.436]    [Pg.19]    [Pg.413]    [Pg.495]   


SEARCH



Actuated valves, electric field

Actuators electrical characterization

Actuators electrical control signals

Actuators, electrically active polymers

Bespak Piezo Electric Actuator

Electrical Shape Memory Actuators

Electrically active polymer materials actuation

Electrically actuated device

Piezo-electrical actuator

Soft actuators, electrical response

© 2024 chempedia.info