Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Activity monitor

Personal monitoring devices (sometimes referred to as "dosimeters") are carried or worn by individuals and are used to measure that individual s exposure to particular chemical(s). Devices that include a pump are called "active" monitors devices that do not include a pump are called "passive" monitors. Such devices are currently used for research purposes. It is possible that sometime in the future they may also be helpful in lAQ investigations in public and commercial buildings. [Pg.239]

Twelve McxJulcs addressing environmental activities monitored by liPA, UCRA, OSIIA, CERCIA, and DOT regulations. Includes SARA reporting module containing MSDS and production information, SARA reporting assi.stancc, tracking capabilities. [Pg.297]

Which monitoring approach is more effective Generally speaking, an active approach allows more systematic and thorough monitoring of advertisements and promotion activities. In practice, its effectiveness depends on how it is done, and what happens after a violation has been identified. If active monitoring is carried out only sporadically, with minimal in-depth examination of dmg advertisements and promotion, it is unlikely to be effective. If there are no sanctions, or only small fines are imposed when a violation is discovered, then the deterrent effect is minimal. For example, a pharmaceutical... [Pg.100]

Vitamin K content of enteral nutrition formulas may affect pharmacological activity. Monitor and titrate dose to maintain therapeutic international normalized ratio (INR)... [Pg.141]

Gautier S.M., Blum L.J., Coulet P.R., Dehydrogenase activity monitoring by flow injection analysis combined with luminescence based fibre-optic sensors, Anal. Chim. Acta 1992 266 331-338. [Pg.177]

Isothermal storage tests (1ST), scanning or isothermal heat-flux micro-calorimeters, thermal activity monitor (TAM)—see Section 2.3.2.1,... [Pg.17]

A liquid flow microcalorimeter, the thermal activity monitor (TAM), is commercially available from ThermoMetric (formerly LKB/Bofors). This instrument consists of two glass or steel ampules with a volume of 3 to 4 cm3 (25 cm3 ampule available with a single detector), placed in a heat sink block. Recently, an injection-titration sample vessel was developed which acts as a microreactor. This vessel is provided with flow-in, flow-out, and titration lines, with a stirring device. The isothermal temperature around the heat sink is maintained by a controlled water bath. Each vessel holder, containing an ampoule, is in direct contact with a thermopile array, and the two arrays are joined in series so that their output voltages subtract. The two pairs of thermopile arrays are oppositely connected to obtain a differential output,... [Pg.63]

A comparison has been made between small scale test results and a field trial at a 17-ton scale for a solid compound [217]. The test results from a very sensitive calorimeter (Thermal Activity Monitor from ThermoMetric, Sweden) were substituted in a model, and the self-heating situation in bulk containers was predicted. The large-scale trial was carried out in a steel rectangular container lined with polyethylene. A control device was used to keep the container at a temperature of 40 to 45°C. Several thermocouples enabled monitoring of the temperature as a function of time in different places in the large container. [Pg.155]

NEAR INFRARED IMAGING AND SPECTROSCOPY FOR BRAIN ACTIVITY MONITORING... [Pg.341]

With these motivations as a driving force, the research into NIR based brain activity monitoring have blossomed in the past 20 years with growing number of potential applications. So far, brain activity monitoring has seen applications in physiological studies of brain disfunction, preterm neonatal care, education and training, and cognitive workload assessment. [Pg.342]

Near Infrared Imaging and Spectroscopy for Brain Activity Monitoring 343... [Pg.343]

The animal s movements (walking, jumping) while on the flat surface of the cart are evaluated quantitatively on a scale of 1 (hypoactive) to 5 (hyperactive), with 3 being the normal state. The data can be upgraded to interval data if one has and utilizes one of the electromagnetic activity-monitoring instruments. [Pg.748]

Accountability, management practices, 69-70 Active controls, process controls, 98 Active monitoring, management practices, 114... [Pg.194]

That derivatization may increase rather than decrease peptidase-catalyzed degradation is illustrated with aspartame (6.79, R = MeO), the C-terminal methyl ester of the dipeptide Asp-Phe. The metabolism of this artificial sweetener was compared to that of the underivatized dipeptide (6.79, R = H) and of the corresponding amide Asp-Phe-NH2 (6.79, R = NH2) in microvillar membranes obtained from human duodenum, jejunum, and ileum [189]. The activities monitored were clearly those of peptidases as shown by the effects of inhibitors. Whereas the peptide bond in Asp-Phe and Asp-Phe-NH2 was hydrolyzed at a comparable rate, that in aspartame was hydrolyzed approximately twice as fast. This is an interesting and favorable situation, given that aspartame is expected to be degraded once it has elicited its effect in the buccal cavity. [Pg.342]

Regarding the shelf life issue, it is always prudent to widely and diligently publicize any known limitations to a deployed model, actively monitor the model s performance with respect to both its outputs and its health indicators (T and 0, and to promptly address any model updates that might be required. [Pg.434]

The advent of a more active monitoring role by the sponsor and audits with the global framework of ICH GCP and other guidelines has significantly increased the quality of therapeutic trials sponsored by pharmaceutical companies. The new standards now also apply to trials conducted independently by individual clinicians. [Pg.232]

Adverse event and ADR reporting requirements are similar to those for clinical trials, with greater emphasis on the authorised prescriber being responsible for reporting any ADR to the TGA, the sponsor and HREC as the sponsor will not normally be actively monitoring the use of the product. [Pg.680]

Gl Cholinesterase inhibitors may be expected to increase gastric acid secretion because of increased cholinergic activity. Monitor patients closely for symptoms of active or occult Gl bleeding, especially those at increased risk for developing ulcers. GU Cholinomimetics may cause bladder outflow obstruction. [Pg.1169]


See other pages where Activity monitor is mentioned: [Pg.385]    [Pg.459]    [Pg.206]    [Pg.52]    [Pg.98]    [Pg.18]    [Pg.277]    [Pg.169]    [Pg.341]    [Pg.342]    [Pg.342]    [Pg.124]    [Pg.124]    [Pg.850]    [Pg.15]   
See also in sourсe #XX -- [ Pg.159 ]

See also in sourсe #XX -- [ Pg.732 ]




SEARCH



Activated sludge plant monitoring

Active monitoring equipment

Active monitoring, management practices

Chemical Monitoring Activity

Chemical Monitoring Activity (CMA

First Example Activity Monitor

Locomotor activity as monitored in automated cages and behavioural characteristics

Mental activity monitoring

Monitoring bacterial activity

Monitoring, active

Monitoring, active

Near Infrared Imaging and Spectroscopy for Brain Activity Monitoring

Passive activated carbon monitor

Project activity monitoring system

Safety monitoring procedures, active

Safety monitoring procedures, active audits

Safety monitoring procedures, active systems

Thermal activity monitor

Thermal activity monitor advantage

Thermal activity monitoring

© 2024 chempedia.info