Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Viewing field

Fig. 7.1.2 Crystals of Chaetopterus photoprotein grown in a solution of ammonium sulfate. The width of the view field is approx. 300 pm. Fig. 7.1.2 Crystals of Chaetopterus photoprotein grown in a solution of ammonium sulfate. The width of the view field is approx. 300 pm.
Therefore, the velocities of liquid are consistent with the velocities of particles, that is, the motion of nano-particles can reflect the flow of liquid verily in the given condition. Figures 39 and 40 show the comparison of the two liquid samples with different mass concentration of the nanoparticles at different flow rates. Generally, particle velocity increases synchronously with the liquid flow rate, but the velocity becomes dispersive when it exceeds 300 /u,L/min. The more the particles were added in the liquid, the more dispersive of the velocities of the particles were observed. Several possible causes can result in this phenomenon. One possible reason is that when the velocity of flow becomes large enough, the bigger particles in the liquid cannot follow the flow as the smaller particles do, or bigger particles will move slower than the liquid around them, so the velocities of particles will distribute dispersedly. Another possible reason is that when the velocity of flow increases the time for particles to traverse, the view field of the microscope will decrease. As a result, the number of data points in the trace of a particle... [Pg.27]

Note that the separability of the two contributions of the polar effect is attained with difficulty in fact, attempts to separate the polar effect contributions have been unsuccessful, so they are usually considered together. However, from a theoretical point of view, field effects have been studied using the Kirkwood-Westheimer [Kirkwood and Westheimer, 1938 Westheimer and Kirkwood, 1938] and Tanford models [Tanford, 1957]. [Pg.145]

Infrared microscopes are commercially available from a number of companies worldwide, and operate much like conventional visible light microscopes. The IR radiation follows the same path as the sample iUumination Ught, so that IR micro-spectroscopy can be performed on the sample at the center of the viewing field. Because of their design, they are also equipped with a number of convenient methods for enhanced sample visualization. These include polarized light (visible and IR), fluorescence illumination and differential interference contrast (DIG), all of which are well known and frequently used to identify biological sample histology. [Pg.457]

Early marine cements are recognized in a few cases where high-volume cements have 5 OpDB values near zero, indicating low-temperature crystallization near the sediment-water interface in marine pore water (Fig. lOA). For example, on the east side of the basin early marine calcite cements are reported for the Mountain View field (5 OpDB= +0.3%o. [Pg.277]

The capture board allows pre-determined areas of the marine radar s view field to be extracted and stored as 8-bit images on the PC. The coverage of the digital image is controlled by various capture parameters described in detail in Robinson et al. (1999). In the present case, the maxi-... [Pg.290]

Try both the Crossed eyes and the Relaxed eyes options in the Stereo dialogue box to find your preferred way of viewing. You may need to use a card or something similar (a floppy disk ) to separate the field of view for each eye, before you can achieve a stereo view.field of view for each eye, before you can achieve a stereo view. [Pg.241]

Generally, from physical point of view, field rp suffer discontinuity at the interface. Then such interface is called as surface of discontinuity. More precisely, a disturbance in the continuity of a phenomenon or physical field is termed as singularity. The singularity will present as discontinuous functions or their derivatives. The examples of the first type are shock and acceleration waves. (A surface that is singular with respect to some quantity and that has a nonzero speed of propagation is said to be a propagating singular surface or wave.)... [Pg.256]

Wearable Electronics A highlight of the 2014 Consumer Electronic Show was wearable electronics. One example is the computerized display glasses that present visuals just above the normal eye viewing field. The eyeglasses have a display, camera and computer. The model for the show also handled voice commands from the wearer. [Pg.9]

CAVA includes a complete set of validation procedures like rear view mirror, viewing fields, security belts, underfloor clearances, lamp positions, pedestrian protection, and much more. Each function contains different parameters and settings that are determined by local authorities and described in corresponding norms. [Pg.273]

For increased sensitivity, many simple polarimeters have an optical device that divides the viewed field into three adjacent parts (triple-shadow polarimeter Fig. 5.50). A very slight rotation of the analyzer will cause one portion to become dimmer and the other lighter (Fig. 5.50a and 5.50c). The angle of rotation reading (a) is recorded when the field sections all have the same intensity. An accuracy of 0.1° can be obtained. [Pg.110]

Figure 4.2a shows a cross-sechonal transmission electron microscopy (XTEM) image of the fabricated mulhlayered Ge/Si02 nanolenses [8]. The Ge QDs had an average diameter and density of 70 5 nm and 4.5 x 10 cm, respectively. A top view field-emission scanning electron microscopy image is shown in Figure 4.2b. [Pg.72]

Liquid crystal displays utilizing scattering effects operated in the reflective mode have a mirrored backing that throws the light scattered at the liquid crystal back through the device into the viewing field. Reflective back electrodes generally limit the readability appreciably because of unwanted reflections. Display devices of this type are therefore hardly usable in practice unless special measures are taken. [Pg.105]

When a nematic hquid crystal is cooled down from the isotropic phase, oriented nematic droplets are physically adsorbed physics on the interface. As a result a TN-LCD cell with a wide viewing field is formed [33]. This device is called amorphous TN-LCD [30]. [Pg.66]


See other pages where Viewing field is mentioned: [Pg.503]    [Pg.503]    [Pg.114]    [Pg.503]    [Pg.137]    [Pg.245]    [Pg.208]    [Pg.245]    [Pg.197]    [Pg.639]    [Pg.503]    [Pg.503]    [Pg.486]    [Pg.357]    [Pg.348]    [Pg.647]    [Pg.153]    [Pg.87]    [Pg.88]    [Pg.74]    [Pg.350]    [Pg.103]    [Pg.183]    [Pg.132]    [Pg.29]    [Pg.224]    [Pg.1879]    [Pg.145]    [Pg.242]    [Pg.1695]    [Pg.167]    [Pg.237]   
See also in sourсe #XX -- [ Pg.132 ]




SEARCH



Detector field of view

Extended Field of View

FOV - Field of View

Field of view

Field of view shields

Scan field of view

Sea-viewing wide field-of-view sensor

Sea-viewing wide field-of-view sensor SeaWiFS)

Useful field of view

© 2024 chempedia.info