The pressure—proof capability of a sealed cell has limitations, and the pressure generated in a sealed cell depends on the amount of gas produced by the substance being tested. The amount of sample for typical self—reactive substances is thus confined to 1 to 3 mg. This is an advantage of the SC-DSC method in that safety is ensured and that a trace amount of sample suffices. In contrast, the difficulty of accurately weighing a sample and the occurrence of relative errors are problems. Moreover, no correct exothermic peaks may be obtained if the amount of sample is too small. [Pg.85]

The term column switching in liquid chromatography is used if two or more columns are connected to form a network. Column switching is a technique that changes the direction of flow of the mobile phase by valves, so the effluent from a primary column passes to a secondary column for a defined period of time as illustrated in Fig. 2. The objectives of column switching are to increase the chromatographic resolution and selectivity, to enrich trace amounts of sample, to protect sensitive detectors such as electrochemical detectors from contamination by coextractives, to prevent destabilization of the chromatographic equilibrium of the column by coextractives, and to achieve further objectives or a combination of... [Pg.211]

In considering the form of the analyses for sample depths previously presented, it Is clear that the experiments corresponding to more extensive f1uorinations would be more critically dependent on even trace amounts of sample contamination. [Pg.397]

In this subsection, methods will be considered for preparing trace amounts of samples from which their infrared spectra may be measured, without resorting to using an infrared microscope, by using a beam-condenser accessory positioned in the conventional sample compartment of an FT-IR spectrometer. [Pg.227]

Trace amounts of sample can be analysed with infrared microspectroscopy. The technique, for... [Pg.787]

For analysis, white phosphoms is typically extracted through a fritted thimble with refluxed toluene. Any trace amounts of water are captured in a cahbrated sidearm to the apparatus. The soflds on the frit are weighed, the water measured, and the phosphoms calculated by difference. For impure samples of phosphoms, the toluene extract may be analy2ed with a gas chromatograph (gc) equipped with a phosphoms—nitrogen detector. [Pg.352]

A gas chromatographic determination of benzotrichloride and related compounds ia the work environment, after adsorption on a polymeric adsorbant and desorption with CCl has been reported (61). Trace amounts of benzyl chloride, benzal chloride, and benzotrichloride ia environmental samples can be analyzed by Method 8120 of EPA ManualSW-846 with modifications (62). [Pg.61]

For capillary columns fused siHca is the material of choice for the column container. It has virtually no impurities (<1 ppm metal oxides) and tends to be quite inert. In addition, fused siHca is relatively easily processed and manufacture of columns from this material is reproducible. In trace analysis, inertness of tubing is an important consideration to prevent all of the tiny amounts of sample from becoming lost through interaction with the wall during an analysis. [Pg.107]

In this work, a simple, rapid and sensitive Flame Atomic Absolution Spectrometry (FAAS) method has been developed for the determination of trace amount of Co + in vaiious samples after adsoi ption of its complex on modified Analcime using a Schiff base Bis-[(2,2 -dihydroxy)-N,N -diethylen-triamino-l,r-naphtaldimine] by column method in the pH range (4-7) at flow rats 1 ml-minf... [Pg.284]

Nowadays the one of the leading cause of death in industrial country is Heart Failure (HF). Under the pathological conditions (e.g., Ischemic Heart Disease (IHD)) the changes in the enzymes activity and ultrastructure of tissue were obtained. The behavior of trace elements may reflect the activity of different types of enzymes. Pathological changes affects only small area of tissue, hence the amount of samples is strictly limited. Thereby, nondestructive multielemental method SRXRF allow to perfonu the analysis of mass samples in a few milligrams, to save the samples, to investigate the elemental distribution on the sample area. [Pg.353]

Another aspect of cost reduction would be solvent economy. The need to preferentially select inexpensive solvents and employ the minimum amount of solvent per analysis would be the third performance criteria. Finally, to conserve sample and to have the capability of determining trace contaminants, the fourth criterion would be that the combination of column and detector should provide the maximum possible mass sensitivity and, thus, the minimum amount of sample. The performance criteria are summarized in Table 1. Certain operating limits are inherent in any analytical instrument and these limits will vary with the purpose for which the instrument was designed. For example, the preparative chromatograph will have very different operating characteristics from those of the analytical chromatograph. [Pg.362]

Activation procedures (Shimomura, 1989). To activate trace amounts of panal, several granules of the crystals of ammonium sulfate are added to 5-50 il of a sample made in 30% methanol, making sure that (NH4)2S04 is in excess to saturate the solution. The mixture is left standing at room temperature for 1 h (85% activation) or one night (complete activation). After the activation, 1 jig of panal emits about 1.5 x 1010 photons using the assay method given below. [Pg.279]

DI water is not equivalent to distilled water in all ways. While the content of most ionic species is very low, it does contain dissolved gases, such as air and carbon dioxide. The latter caused problems in one laboratory when DI water was used for diluting poorly buffered samples for pH measurements. Erratic results were also reported in another case when DI water was used in connection with the determination of trace amounts of boron. The manufacturer explained that when close to exhaustion, the resin used would no longer be effective in holding back traces of this element. [Pg.29]


See other pages where Trace amount of sample is mentioned: [Pg.423]    [Pg.112]    [Pg.190]    [Pg.52]    [Pg.858]    [Pg.75]    [Pg.20]    [Pg.494]    [Pg.399]    [Pg.75]    [Pg.295]    [Pg.423]    [Pg.112]    [Pg.190]    [Pg.52]    [Pg.858]    [Pg.75]    [Pg.20]    [Pg.494]    [Pg.399]    [Pg.75]    [Pg.295]    [Pg.45]    [Pg.210]    [Pg.451]    [Pg.367]    [Pg.134]    [Pg.397]    [Pg.168]    [Pg.46]    [Pg.492]    [Pg.273]    [Pg.170]    [Pg.170]    [Pg.200]    [Pg.181]    [Pg.38]    [Pg.54]    [Pg.11]    [Pg.416]    [Pg.578]    [Pg.10]    [Pg.152]    [Pg.127]    [Pg.628]    [Pg.646]    [Pg.245]   