Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Titration strong

Titrating Strong Acids and Strong Bases For our first titration curve let s consider the titration of 50.0 mb of 0.100 M HCl with 0.200 M NaOH. For the reaction of a strong base with a strong acid the only equilibrium reaction of importance is... [Pg.280]

Titrating strong acid with strong base [H+J - [OH ]... [Pg.221]

Titrating strong base with strong acid... [Pg.221]

In all argentimetric titrations strong light (including daylight) should be avoided as it can lead to decomposition of the silver salts. [Pg.158]

Table 6.1 pH titration strong acid/strong base at 25°C... [Pg.144]

Fraction F Titrated Strong Acid Strong Base... [Pg.268]

Strong Acid-Strong Base Titrations Weak Acid-Strong Base Titrations Strong Acid-Weak Base Titrations Acid-Base Indicators... [Pg.680]

The encapsulated guest molecules are generally size- and shape-matching hydrophobic molecules that are neutral, anions, or cations such as ADM, nitrophe-nols, ibuprofen, diadamantane, or tetra(n-propyl)ammonium (TPA). Analysis of typical potentiometric pH titrations strongly indicated that the 4 4 complex (20) ... [Pg.39]

In making this change we must however forfeit oru ability to titrate strong bases for the obvious reason that they will be protonated by the solvent. For example, acetic acid has a working range for the study of bases with pK s in the approximate range +2.5 to —4. [Pg.249]

The method is based on the conversion of urea to amnionium carbonate and the estimation of the latter by titration with standard acid. For this purpose, two equal quantities of urea (or urine) are measured out into two flasks A and B. A is treated with 10 ml. of a strong urease preparation and some phenol-phthalein, warm water is added and the mixture is adjusted by the addition of V/io HCl from a burette A until the red colour is just discharged. This brings the mixture to about pH 8 (the optimum for urease) and also prevents loss of ammonia. [Pg.520]

CHjCiMeljCHjCO-U.sed as indicators in the titration of strong acids or strong bases... [Pg.159]

H0CH3)3CNHH3 121.137 Tris(hydroxymethyl)aminomethane is available commercially as a primary standard. Dry at 100-103°C (<110°C). In titrations with a strong acid the equivalence point is at about pH 4.5-5. Equivalent weight is the formula weight. [J. H. Eossum, P. C. Markunas, and J. A. Riddick, Anal. Chem., 23 491 (1951).]... [Pg.1151]

ClOy + 3 H3ASO3 (excess boil with strong HCl) = CF + 3 H3ASO4 Titrate excess H3ASO3 with bromate HCIO3/6 = 14.077... [Pg.1162]

Probably the most extensively applied masking agent is cyanide ion. In alkaline solution, cyanide forms strong cyano complexes with the following ions and masks their action toward EDTA Ag, Cd, Co(ll), Cu(ll), Fe(ll), Hg(ll), Ni, Pd(ll), Pt(ll), Tl(lll), and Zn. The alkaline earths, Mn(ll), Pb, and the rare earths are virtually unaffected hence, these latter ions may be titrated with EDTA with the former ions masked by cyanide. Iron(lll) is also masked by cyanide. However, as the hexacy-anoferrate(lll) ion oxidizes many indicators, ascorbic acid is added to form hexacyanoferrate(ll) ion. Moreover, since the addition of cyanide to an acidic solution results in the formation of deadly... [Pg.1169]

Masking by oxidation or reduction of a metal ion to a state which does not react with EDTA is occasionally of value. For example, Fe(III) (log K- y 24.23) in acidic media may be reduced to Fe(II) (log K-yyy = 14.33) by ascorbic acid in this state iron does not interfere in the titration of some trivalent and tetravalent ions in strong acidic medium (pH 0 to 2). Similarly, Hg(II) can be reduced to the metal. In favorable conditions, Cr(III) may be oxidized by alkaline peroxide to chromate which does not complex with EDTA. [Pg.1170]

The utility of acid-base titrimetry improved when NaOH was first introduced as a strong base titrant in 1846. In addition, progress in synthesizing organic dyes led to the development of many new indicators. Phenolphthalein was first synthesized by Bayer in 1871 and used as a visual indicator for acid-base titrations in 1877. Other indicators, such as methyl orange, soon followed. Despite the increasing availability of indicators, the absence of a theory of acid-base reactivity made selecting a proper indicator difficult. [Pg.278]

Titrating a Weak Acid with a Strong Base For this example let s consider the titration of 50.0 mL of 0.100 M acetic acid, CH3COOH, with 0.100 M NaOH. Again, we start by calculating the volume of NaOH needed to reach the equivalence point thus... [Pg.281]

After the equivalence point NaOH is present in excess, and the pH is determined in the same manner as in the titration of a strong acid with a strong base. For example, after adding 60.0 mb of NaOH, the concentration of OH is... [Pg.283]

The approach that we have worked out for the titration of a monoprotic weak acid with a strong base can be extended to reactions involving multiprotic acids or bases and mixtures of acids or bases. As the complexity of the titration increases, however, the necessary calculations become more time-consuming. Not surprisingly, a variety of algebraic and computer spreadsheet approaches have been described to aid in constructing titration curves. [Pg.284]

This approach can be used to sketch titration curves for other acid-base titrations including those involving polyprotic weak acids and bases or mixtures of weak acids and bases (Figure 9.8). Figure 9.8a, for example, shows the titration curve when titrating a diprotic weak acid, H2A, with a strong base. Since the analyte is... [Pg.286]

Figure 9.8b shows a titration curve for a mixture consisting of two weak acids HA and HB. Again, there are two equivalence points. In this case, however, the equivalence points do not require the same volume of titrant because the concentration of HA is greater than that for HB. Since HA is the stronger of the two weak acids, it reacts first thus, the pH before the first equivalence point is controlled by the HA/A buffer. Between the two equivalence points the pH reflects the titration of HB and is determined by the HB/B buffer. Finally, after the second equivalence point, the excess strong base titrant is responsible for the pH. [Pg.287]

Where Is the Equivalence Point We have already learned how to calculate the equivalence point for the titration of a strong acid with a strong base, and for the titration of a weak acid with a strong base. We also have learned to sketch a titration curve with a minimum of calculations. Can we also locate the equivalence point without performing any calculations The answer, as you may have guessed, is often yes ... [Pg.287]

The principal limitation to using a titration curve to locate the equivalence point is that an inflection point must be present. Sometimes, however, an inflection point may be missing or difficult to detect, figure 9.9, for example, demonstrates the influence of the acid dissociation constant, iQ, on the titration curve for a weak acid with a strong base titrant. The inflection point is visible, even if barely so, for acid dissociation constants larger than 10 , but is missing when is 10 k... [Pg.287]

Consider again the titration of a monoprotic weak acid, ITA, with a strong base. At any point during the titration the weak acid is in equilibrium with 1T30+ and A ... [Pg.292]

Although not commonly used, thermometric titrations have one distinct advantage over methods based on the direct or indirect monitoring of plT. As discussed earlier, visual indicators and potentiometric titration curves are limited by the magnitude of the relevant equilibrium constants. For example, the titration of boric acid, ITaBOa, for which is 5.8 X 10 °, yields a poorly defined equivalence point (Figure 9.15a). The enthalpy of neutralization for boric acid with NaOlT, however, is only 23% less than that for a strong acid (-42.7 kj/mol... [Pg.294]

Perhaps the most obvious limitation imposed by Ks is the change in pH during a titration. To see why this is so, let s consider the titration of a 50 mb solution of 10 M strong acid with equimolar strong base. Before the equivalence point, the pH is determined by the untitrated strong acid, whereas after the equivalence point the concentration of excess strong base determines the pH. In an aqueous solution the concentration of H3O+ when the titration is 90% complete is... [Pg.295]

Oxidizing the protein converts the nitrogen to NH4+. Why is the amount of nitrogen not determined by titrating the NH4+ with a strong base ... [Pg.297]


See other pages where Titration strong is mentioned: [Pg.562]    [Pg.241]    [Pg.863]    [Pg.148]    [Pg.144]    [Pg.430]    [Pg.138]    [Pg.726]    [Pg.366]    [Pg.234]    [Pg.562]    [Pg.241]    [Pg.863]    [Pg.148]    [Pg.144]    [Pg.430]    [Pg.138]    [Pg.726]    [Pg.366]    [Pg.234]    [Pg.1868]    [Pg.190]    [Pg.554]    [Pg.1117]    [Pg.281]    [Pg.283]    [Pg.284]    [Pg.284]    [Pg.286]    [Pg.287]    [Pg.288]    [Pg.296]    [Pg.297]    [Pg.297]   


SEARCH



© 2024 chempedia.info