THREE PHASE AC

The easiest and generally best way to start ac motors is to have the magnetic field of the stator be rotating. Then any conductive rotor design will be self-starting. This is one of the advantages of three-wire, three-phase electricity. [Pg.222]

It is quite common for large electric motors and heaters to run on 208 volts. This can be obtained from substation transformer 208V secondary windings of either type (wye, or delta), if the coil has the right number of turns. It can also be obtained from 240V secondaries (but with delta, as explained later on page 224). [Pg.223]

When 120 volts is used for U.S. house or office wiring, it can be taken from the middle of the transformer s secondary windings, as shown in Fig. 20.8. Either a fourth wire can be used (for heavy currents), or else a very good ground is necessary, but neither are desirable for long distances. [Pg.223]

Another alternative for 120 volt service is to take it from a center-tapped delta type transformer, as shown in Fig. 20.9. However, where heavy usage of the 120 [Pg.223]

Solid Armature Wire Wound Squirrel Cage Multipole [Pg.226]


The following equations are useful in determining the eurrent, voltage, horsepower, torque, and power factors for three phase AC motors ... [Pg.267]

GM-EMD Testing of 4-axle radial trucks on BN 1989 GM-EMD First successful three phase AC... [Pg.727]

Electric power is almost always transmitted as three-phase AC current. In domestic use, current is often distributed from a substation at 13,200, 6,600, or 2,300 V, which is stepped down by a transformer close to the point of use to 600, 480, and 240 V for three-phase current for commercial power and 240 and 120 V for single-phase, three-wire current for household power and lights. If DC current is required, synchronous converters or rectifiers are used to convert the AC supply to DC. [Pg.294]

There are two general types of steam turbines extraction and condensing. The most common turbine with which the process operator comes into contact is used to spare an electric-motor-driven centrifugal pump. The three-phase, AC motors used in the United States and South America are either 1800 or 3600 rpm. The motors used in Europe are 1500 or 3000 rpm. Small steam turbines (20 to 500 hp) used to drive centrifugal pumps, are rated for the same speed as the electric motors that are used in that particular service. [Pg.203]

With the assumption that a three-phase AC grid with industrial frequency (50-60 cps) represents the state of the art of a power grid in a coal mine, two features shall be considered in parallel to establish a network and... [Pg.493]

Figure 12.1 Schematic diagram of a three-phase AC grid with isolated neutral N (type IT). Figure 12.1 Schematic diagram of a three-phase AC grid with isolated neutral N (type IT).
Figure 12.8 Fault response of UR 1/400, compared with a standard low voltage circuit breaker. A three-phase AC current of 80A rms to a load is followed by a short-circuit in a 50 cps grid. Figure 12.8 Fault response of UR 1/400, compared with a standard low voltage circuit breaker. A three-phase AC current of 80A rms to a load is followed by a short-circuit in a 50 cps grid.
The crematorium of Auschwitz was originally constructed in accordance with diagram Topf D50042 of September 25, 1941, which had been drawn up for the construction of the third oven.95 Each oven was equipped with its own forced-air installation this consisted of an air blower, which was operated with a 1.5 hp three-phase AC motor coupled directly to the blower shaft, and an appropriate duct. The square stack originally had an area of 500 x 500 mm2 (19.7" x 19.7"). The exhaust installation, with a capacity of about 4,000 m3/h (141,200 cu.ft./h) of stack gas, consisted of an exhaust fan powered with a 3 hp three-phase AC motor coupled directly to the blower shaft an air shutter... [Pg.386]

During operation, the MULVFS is powered by 480-V three-phase AC power from the ship and is controlled by an Apple 11 computer programmed to disconnect the power in the event of a short circuit or imbalance in load. The computer also monitors the flow rate of one pump unit and records and graphically displays this information along with elec-... [Pg.160]

The stator, also called the armature, carries the three-phase AC winding. The rotor, also called the field, carries the DC excitation or field winding. The field winding therefore rotates at the shaft speed and sets up the main magnetic flux in the machine. [Pg.62]

DC methods mostly use shunt or compound wound motors. Occasionally series wound motors are used when high torque at low speeds is required. These machines are fed with DC voltage derived from a three-phase AC source using a thyristor converter. The thyristor converter rectifies the AC into DC but with control over the magnitude of the average DC voltage. Thyristors are also called silicon controlled rectifiers . [Pg.385]

Short-circuit current calculation in three-phase AC systems. Third impression... [Pg.524]

Part 1 Eactors for the calculation of short-circuit currents in three-phase AC systems according to IEC60909. [Pg.524]

Once the electrodes and treatment zone materials were installed, the electrodes were wired and plumbed. The electrical system consisted of a steel buss bar welded across the tops of the steel plates. The end plate was connected to the buss wire, which was in turn connected to a large DC rectifier. The rectifier, relocated from the Paducah site and reconfigured, converts standard 208-V, three-phase AC power (600-A service) to a maximum of 190-V and 1000-A DC. There were two anodes rated at 500A each and one central cathode with two buss wires. [Pg.642]

Fig. 7. Superconducting generator without moving parts, excited by three-phase ac. Fig. 7. Superconducting generator without moving parts, excited by three-phase ac.
Generator with No Moving Parts. The movement of the spot can be effected purely electrically by placing a number of magnets close to each other in a row and energizing them one after another. A device of this kind which is operated by three-phase ac is illustrated in Fig. 7. [Pg.347]

Three-phase AC induction motors were used in the power equipment (pump. Roots blower. [Pg.354]

Welchko, B. A., Lipo, T. A., Jahns, T. M., Schulz, S. E. (2004). Fault tolerant three-phase ac motor drive topologies A comparison of features, costs, and hmitations. IEEE Transactions on Power Electronics, 19(4), 1108-1116. [Pg.218]

The harmonic pattern of a full wave diode bridge is well known and well documented in literature. In the diagram of Figure 2, six diodes are used for full wave rectification of a three phase AC supply, feeding the intermediate DC circuit of a VFD. The AC current will exhibit a 6 pulse pattern, resulting from each half of the AC sine wave conducting via a particular diode. This AC current does not have a pure sinusoidal shape anymore it now includes the combination of a fundamental component (50 or 60 Hz) to which additional frequencies are superimposed. [Pg.152]

The present goal of the BNL program is the construction of a 100 m outdoor three-phase ac cable rated at 138 kV and 1000 MVA. [Pg.339]

Incoming three-phase AC power is rectified and smoothed to generate a variable voltage DC supply. This DC voltage is then switched among the three output phases to generate a step waveform that approximates a sinusoidal waveform. The switching is done by six SCRs (silicon-controlled rectifiers), which are sequentially fired at the proper frequency by a solid-state circuit. [Pg.52]

Synchros are rather complex and expensive three-phase AC machines, which are constructed to be precise and rugged. Synchros are capable of measuring angular differences in the positions (up to 180°) of two continuously rotating shafts. In addition, synchros may function simultaneously as reference input, output measurement device, feedback path, and comparator (Fig. 18.2(c)). [Pg.1920]

The power distribution achieved by a Scott switch should be mentioned as the third possibility. In this configuration, the three-phase AC connection is changed to two single phase power sources. Because both phases are offset electrically by 90°, this method is especially suitable for square tanks or electrode arrays. [Pg.78]

Auxiliary motor its purpose is to serve as a standby to enable the kiln to continue rotating (at reduced speed) in the event of a power supply failure or fault in the main motor. If the cement works has an emergency power supply system, the auxiliary motor may be a three-phase AC machine, otherwise an internal combustion engine - diesel or petrol (gasoline) - designed for quick starting will be provided. [Pg.168]


See other pages where THREE PHASE AC is mentioned: [Pg.2490]    [Pg.472]    [Pg.438]    [Pg.85]    [Pg.77]    [Pg.387]    [Pg.27]    [Pg.77]    [Pg.605]    [Pg.2245]    [Pg.952]    [Pg.293]    [Pg.136]    [Pg.957]    [Pg.785]    [Pg.2494]    [Pg.181]    [Pg.330]    [Pg.155]    [Pg.187]    [Pg.472]    [Pg.21]    [Pg.222]    [Pg.283]    [Pg.288]    [Pg.288]   