Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Test line

Cold crank performance, battery life expectancy, and freedom from maintenance are generally co-affected by the separators, whereas ampere-hour capacity remains largely unaffected at a given separator thickness. The properties of the different leaf and pocket separators are compared in Table 10. These typical separator properties (lines 1-4) are reflected in the electrical results of battery tests (lines 5-8). The data presented here are based on the 12 V starter battery standard DIN 43 539-02 tests based on other standards lead to similar results. [Pg.269]

Yamanashi MAGLEV Test Line, 23 865 Yankee dryer, 18 122, 129 Yard wastes... [Pg.1029]

Conventional batteries in areas of limited productivity were not consolidated. Batteries in areas that contained several wells with considerable 4 production, but which could not justify a new meter site, were replaced with a remote automatic well test header, with production and test lines to neart meter sites. Installation of remote headers provid substantial investment savings over meter site stallation and accomodated automatic well lestL The large conventional batteries located in areas with1 high production volumes were replaced by 16 ne C meter sites. ... [Pg.52]

For each image, an oriented lineal analysis was performed. The measurement, P and L, was performed once, at a reference angle of 0 degrees, and an estimate of the porosity computed according to Equation (5). The grid of test lines was then rotated to a new angle and the measurement of PL repeated. By performing this same... [Pg.23]

Figure 4 A circular grid of parallel test lines superimposed on an image, the grid can be rotated to any orientation. Figure 4 A circular grid of parallel test lines superimposed on an image, the grid can be rotated to any orientation.
This type of model, see Fig. 5, is a one-dimensional approximation of i r) along a fixed test line through the material [9]. In Fig. 5, the sequence pore/wall/pore. .. is simulated... [Pg.599]

Handwriting-spedmen test Line-labyrinth test Line-tradng test... [Pg.202]

Magnetic levitation is an application which could theoretically be used for people transport. Transportation vehicles, such as trains, would be made to float on strong superconducting magnets, eliminating friction between the train and its tracks. This would mean extremely high speeds could be achieved. This was realized in 1990, with a nationally funded project in Japan to develop just such a train. The Yamanashi test line opened in April 1997. On 14 April 1999 a speed of 340 miles per hour was achieved with the MLXOl. [Pg.161]

Test line reagent A second anti-IBDV mAb IgG recognizing a different epitope of the viral protein is similarly purified from ascitic fluid (5), and stored at -20°C in 1 mL aliquots. [Pg.173]

Test line reagent CL (Sigma-Aldrich Cat. No. C5423) is conjugated to bovine serum albumin (BSA, Amresco Inc., Solon, Ohio, Cat. No. 0332) and used as the test line reagent (BSA-CL) (9). Briefly, 5mg of CL dissolved in 4mL of... [Pg.174]

If both the test and control lines turn red, the sample is recorded as positive, indicating the presence of IBDV antigens in the sample. When the control line but not the test line is colored, it is considered as negative. No colored band appears on the membrane indicates an improper testing procedure or deterioration of the strip, and the test should be repeated using a new strip (Fig. 6A). [Pg.177]

The protocol is similar to that described in Subheading 3.1, and differences are clarified as below. In this case, anti-CL mAb IgG is conjugated with colloidal gold and the hapten conjugate, BSA-CL, is used on the test line. A positive standard sample of the hapten is required for the quantitive detection. [Pg.179]

Both control and test lines develop on the strip to which applied the negative standard. The test line is invisible and the control appears on the strip to which applied the positive standard. When testing urine samples, if the test line develop equal intensity to that seen with the negative standard, the sample is recorded as negative indicating no detectable level of CL. If the intensity of the test line is weaker than that of the negative standard, the sample is considered as positive... [Pg.179]

Principles and characteristics of lateral flow strip assays are reviewed. Recent technology developments permit the use of inexpensive electronic readers for interrogating lateral flow strip test results, thus avoiding the inevitable variation and subjectivity of visual inspection to assess the capture of reporter-labeled analyte on test lines of the strip. Protocols for developing lateral flow assays are described, including two specific case studies for assaying cotinine (a small-molecule metabolite of nicotine) in a competitive format, and assaying HIV antibodies in a sandwich-type assay format. [Pg.217]


See other pages where Test line is mentioned: [Pg.49]    [Pg.277]    [Pg.208]    [Pg.128]    [Pg.391]    [Pg.49]    [Pg.245]    [Pg.246]    [Pg.247]    [Pg.250]    [Pg.250]    [Pg.20]    [Pg.20]    [Pg.32]    [Pg.36]    [Pg.593]    [Pg.1216]    [Pg.196]    [Pg.305]    [Pg.90]    [Pg.1351]    [Pg.121]    [Pg.448]    [Pg.448]    [Pg.277]    [Pg.273]    [Pg.396]    [Pg.170]    [Pg.171]    [Pg.171]    [Pg.171]    [Pg.171]    [Pg.171]    [Pg.174]    [Pg.180]   
See also in sourсe #XX -- [ Pg.170 , Pg.171 , Pg.173 , Pg.174 , Pg.177 , Pg.179 , Pg.180 , Pg.217 , Pg.231 , Pg.234 , Pg.237 , Pg.238 , Pg.240 , Pg.241 , Pg.245 , Pg.246 , Pg.247 ]

See also in sourсe #XX -- [ Pg.428 ]




SEARCH



© 2024 chempedia.info