Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Signal pressure

Signal pressure transducer (SPT) at mud pump records wave phase at stad. [Pg.1069]

Pressure variations can be compensated for by measuring both temperature and pressure at a tray location and computing a pseudocomposition signal. This computed composition signal (pressure-compensated temperature) can then be controlled ... [Pg.209]

Obviously, a sensoTs function can be tested at the end of the fabrication process after the sensor is completely assembled and fully packaged. At this time a primary input signal (pressure, acceleration, yaw rate, mass flow, etc.) can be applied directly, and a comprehensive test of the specified performance is possible. Unfortunately, by the time a defective sensor component is packaged, loss of time and capital is maximum, since a fully packaged sensor needs to be discarded. [Pg.224]

When the S3 is opened, the oil of 3 -Gear is provided to the valve and adjust the pressure (CAF) to 2.25 times of S5 signal pressure. When S3 is in closed status, the output pressure is 2.25 times of pressure of line 500. [Pg.93]

Reverse lock valve (refer to Figure 3.17) has two position statuses and is located on upper valve. The valve use the pressure SI S2 as the signal pressure and control the attachment of rear brake belt (B2). [Pg.95]

When the manual-operated valve is position of D-Gear, 3" -Gear, 2 -Gear or 1"-Gear, the transmission fluid flows into the end of valve spring. Ignore the signal pressure and keep the... [Pg.95]

Seek to eliminate hazards by using appropriate engineering controls. Make the modifications as necessary to eliminate hazards and unsafe conditions. The design of machine guards, automobile brakes, traffic signals, pressure relief valves, and ventilation demonstrates engineering controls at... [Pg.15]

Modern subsea trees, manifolds, (EH), etc., are commonly controlled via a complex Electro-Hydraulic System. Electricity is used to power the control system and to allow for communication or command signalling between surface and subsea. Signals sent back to surface will include, for example, subsea valve status and pressure/ temperature sensor outputs. Hydraulics are used to operate valves on the subsea facilities (e.g. subsea tree and manifold valves). The majority of the subsea valves are operated by hydraulically powered actuator units mounted on the valve bodies. [Pg.270]

Data Logger it acquires the external plant parameter signals (e.g. load steam flow, temperature and pressure etc.) required for correlation with the AE activity. [Pg.69]

The technique presented above has been extensively evaluated experimentally using ultrasonic data acquired from a test block made of cast stainless steel with cotirse material structure. Here we briefly present selected results obtained using two pressure wave transducers, with refraction angles of 45° and 0°. The -lOdB frequency ranges of the transducers were 1.4-2.8 MHz and 0.7-1.4 MHz, respectively. The ultrasonic response signals were sampled at a rate of 40 MHz, with a resolution of 8 bits, prior to computer processing. [Pg.92]

Chan,R.W.Y., Hay,D.R., Matthews,J.R., MacDonald,H.A., (1988), Automated Ultrasonic System for Submarine Pressure Hull Inspection , Signal Processing and Pattern Recognition in Nondestructive Evaluation of Materials, C.H.Chen (ed). Springer-Verlag, pp. 175-187... [Pg.103]

P. Simard M. Piriou B. Benoist, A. Masia. Wavelet transformation Filtering of eddy current signals. In l th International Conference on NDe in the nuclear and Pressure Vessel Industries, pages 313-317, 1997. [Pg.333]

This corresponds to the physician s stethoscope case mentioned above, and has been realized [208] by bringing one leg of a resonatmg 33 kHz quartz tiinmg fork close to the surface of a sample, which is being rastered in the x-y plane. As the fork-leg nears the sample, the fork s resonant frequency and therefore its amplitude is changed by interaction with the surface. Since the behaviour of the system appears to be dependent on the gas pressure, it may be assumed that the coupling is due to hydrodynamic mteractions within the fork-air-sample gap. Since the fork tip-sample distance is approximately 200 pm -1.120), tire teclmique is sensitive to the near-field component of the scattered acoustic signal. 1 pm lateral and 10 mn vertical resolutions have been obtained by the SNAM. [Pg.1717]

With M = He, experimeuts were carried out between 255 K aud 273 K with a few millibar NO2 at total pressures between 300 mbar aud 200 bar. Temperature jumps on the order of 1 K were effected by pulsed irradiation (< 1 pS) with a CO2 laser at 9.2- 9.6pm aud with SiF or perfluorocyclobutaue as primary IR absorbers (< 1 mbar). Under these conditions, the dissociation of N2O4 occurs within the irradiated volume on a time scale of a few hundred microseconds. NO2 aud N2O4 were monitored simultaneously by recording the time-dependent UV absorption signal at 420 run aud 253 run, respectively. The recombination rate constant can be obtained from the effective first-order relaxation time, A derivation analogous to (equation (B2.5.9). equation (B2.5.10). equation (B2.5.11) and equation (B2.5.12)) yield... [Pg.2120]

Detection limit. The detection limit of an instrument should be differentiated from its sensitivity. The detection limit reflects the smallest flow of sample or the lowest partial pressure that gives a signal that can be distinguished from the background noise. One must specify the experimental conditions used and give the value of signal-to-noise ratio corresponding to the detection limit. [Pg.436]


See other pages where Signal pressure is mentioned: [Pg.240]    [Pg.240]    [Pg.544]    [Pg.96]    [Pg.15]    [Pg.501]    [Pg.21]    [Pg.199]    [Pg.105]    [Pg.11]    [Pg.588]    [Pg.501]    [Pg.107]    [Pg.579]    [Pg.240]    [Pg.240]    [Pg.544]    [Pg.96]    [Pg.15]    [Pg.501]    [Pg.21]    [Pg.199]    [Pg.105]    [Pg.11]    [Pg.588]    [Pg.501]    [Pg.107]    [Pg.579]    [Pg.17]    [Pg.343]    [Pg.37]    [Pg.38]    [Pg.41]    [Pg.42]    [Pg.71]    [Pg.713]    [Pg.799]    [Pg.812]    [Pg.813]    [Pg.858]    [Pg.1235]    [Pg.1236]    [Pg.2482]    [Pg.3002]    [Pg.380]    [Pg.322]    [Pg.437]    [Pg.249]    [Pg.325]   
See also in sourсe #XX -- [ Pg.319 ]




SEARCH



© 2024 chempedia.info