Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Temperature conditioner

The electrical output of the thermocouple varies with temperature. This output is fed through a flexible cable to an external signal-conditioner circuit to amplify and condition the signal for interfacing to the monitoring system. [Pg.664]

For PM control from combustion sources, the tlue gas enters a coagulation area (e.g., ductwork, a chamber, or a cyclone) to reduce the number of ultrafine particles, and then a gas conditioner to cool the gas to a suitable temperature and saturation state. This is generally accomplished by means of a waste heat recovery heat exchanger to reduce the temperature of the flue gas or by spraying water directly into the hot flue gas stream. [Pg.445]

Convective heat transfer occurs when a fluid (gas or liquid) is in contact with a body at a different temperature. As a simple example, consider that you are swimming in water at 21°C (70°F), you observe that your body feels cooler than it would if you were in still air at 21°C (70°F). Also, you have observed that you feel cooler in your automobile when the air-conditioner vent is blowing directly at you than when the air stream is directed away from you. Both ot these observations are directly related to convective heat transfer, and we might hypothesize that the rate of energy loss from our body due to this mode of heat transfer is dependent on not only the temperature difference but also the typie of surrounding fluid and the velocity of the fluid. We can thus define the unit heat transfer for convection, q/A, as follows ... [Pg.612]

R-401B (22/152a/124) MP66 AlliedSignal DuPont CFC-12 R-500 Blend (moderate glide) Alkylbenzene or polyol ester Alkylbenzene or polyol ester or in some cases mineral oiF Transport Refrigeration retrofits Retrofits including air conditioners dehumidifiers Close to CFC-12. Use where evap. temperature below -10 F. [Pg.327]

Fin spacing will be a compromise between compactness (and cost) and the tendency for the interfm spaces to block with condensed moisture or frost. Spacings will vary from 2 mm on a compact air-conditioner to 12 mm on a low-temperature coldroom coil [8]. [Pg.84]

Control of the indoor cooled condition will be by thermostat in the return airstream, and thus based on room dry bulb temperature. The resulting humidity level will depend on coil characteristics and air flow. Packaged air-conditioners for tropical applications commonly have a design coil sensible/total ratio in the order of 0.7 with entering air at 50% saturation, and will give indoor conditions nearer 45% saturation if used in temperature climates with less latent load (see Chapter 35). [Pg.310]

Winter heating items fitted within room air-conditioners may be electric resistance elements, hot water or steam coils, or reverse cycle (heat pump). One model of water-cooled unit operates with a condenser water temperature high enough to be used also in the heating coil. [Pg.310]

Tannin sludge conditioners are adversely affected by higher temperatures and, without the support of a supplemental PAA polymer, are limited to 350 psig. This probably is also true of lignosulfonates. [Pg.457]

Acryl amide is an important bulk chemical used in coagulators, soil conditioners and stock additives. The chemical synthesis has several drawbacks because the rate of acryl amide formation is lower than the formation of the by-product acrylic acid [54]. Further, the double bonds of the reactants and products cause by-product formations as well as formation of polymerization products. As a result of optimization with methods of molecular engineering, a very high activity of the biocatalyst nitrile hydratase at low temperature is yielded, enabling a successful biotransformation that is superior to the chemical route. Here, the synthesis is carried out at a low temperature of about 5°C, showing a conversion of 100%. [Pg.94]

Heat stroke is much more serious it is an immediate life-threatening situation. The characteristics of heat stroke are a high body temperature (which may reach 106° F or more) a rapid pulse hot, dry skin and a blocked sweating mechanism. Victims of this condition may be unconscious, and first-aid measures should be directed at quickly cooling the body. The victim should be placed in a tub of cold water or repeatedly sponged with cool water until his or her temperature is sufficiently lowered. Fans or air conditioners will also help with the cooling process. Care should be taken, however, not to over-chill the victim once the temperature is below 102° F. [Pg.190]

The separation section of a gas oil cracker looks like a small refinery, as you can see in Figure 5 or in Figure 5—5. In addition to the fractionators and treaters used in the purification section of the simpler ethane cracker, there are facilities to separate the heavier coproducts. In the front end of the separator facilities in Figure 5-4, the cold box option for handling the liquefaction of the gases is shown. Temperatures as low as -220°F are achieved in this super-refrigerator. At those low temperatures, Freon wont do the job. Liquid air, methane, ethylene, or ammonia are often used as the refrigerant in much the same way Freon has been used in an air conditioner. [Pg.73]

Enclosure The main cabinet is divided into two compartments one for the magnet, and one for the electronics. The magnet compartment is maintained at a temperature of 24 + 1 °C for ultimate permanent magnet stability. The electronics compartment is on a separate air conditioner and is less rigorously temperature controlled. Fignre 10.11 shows several pictures of a Qualion Process NMR spectrometer in a NEMA enclosure configured for implementation on-line. [Pg.315]

The energy value of air conditioners is expressed in terms of BTU (British Thermal Unit). 1 BTU equals the amount of heat required to raise the temperature of 1 pound of water by 1 degree Fahrenheit at its maximum density, which occurs at a temperature of 39.1 degree Fahrenheit. 1 BTU is equal to approximately 251.9 calories or 1055 joules. [Pg.8]


See other pages where Temperature conditioner is mentioned: [Pg.236]    [Pg.236]    [Pg.401]    [Pg.151]    [Pg.220]    [Pg.221]    [Pg.9]    [Pg.180]    [Pg.250]    [Pg.405]    [Pg.421]    [Pg.481]    [Pg.135]    [Pg.1105]    [Pg.514]    [Pg.466]    [Pg.29]    [Pg.207]    [Pg.1131]    [Pg.255]    [Pg.371]    [Pg.125]    [Pg.133]    [Pg.152]    [Pg.578]    [Pg.12]    [Pg.742]    [Pg.412]    [Pg.393]    [Pg.70]    [Pg.75]    [Pg.17]    [Pg.25]    [Pg.293]    [Pg.107]   
See also in sourсe #XX -- [ Pg.236 ]




SEARCH



Conditioner

© 2024 chempedia.info