Sihcone contamination has been impHcated as a cause of failure in telephone switching systems and other devices that contain relay switch contacts (507). Analysis of airborne particulates near telephone switching stations showed the presence of siUcones at these locations. Where the indoor use of sihcones is intentionally minimised, outdoor levels were found to be higher than inside concentrations (508). Samples of particulates taken at two New Jersey office buildings revealed sihcone levels that were considerably higher indoors than outdoors. In these cases, indoor sihcone aerosols are beheved to be generated primarily by photocopiers, which use sihcone fuser oils. [Pg.61]

Provision must be made in the wiring to maintain power to the standby pump driver. This will prevent power interruption due to the pressure switch contacts opening when lubricant pressure is restored. Cycling of the standby pump will occur if the circuit is not maintained. A reset will have to be furnished to permit shutting down the standby pump when the main pump is back on stream. [Pg.314]

State B has the same spectrum as HbCO. This analysis for the TR spectra of Figure 3.35 enables the component difference spectra for the Rdeox Rs> Rt> and T intermediates to be determined and these spectra are shown in Figure 3.37. These difference TR spectra, in conjunction with other data for these intermediates, enables a working model for the allosteric reaction coordinate in the HbCO photocycle to be developed as shown in Figure 3.38 and the reader is referred to reference 156 for details. Photolysis of HbCO (A) results in the geminate state, B, where forces are stored in the heme and these forces subsequently lead to rotation of the E and helices that then breaks the interhelical H-bonds in the Rdeoxy intermediate. These H-bonds become restored in the Rs intermediate and subsequently produce a hinge contact formation in the Rj intermediate that is then followed by formation of the switch contact to result in the T intermediate. ... [Pg.174]

The pressure switch is connected to an integrator circuit. The integrator circuit is characterized by an output voltage which changes slowly. This voltage increases when the pressure switch contacts are open indicating that the flow rate is below the set point. When the flow rate is above the set point, the switch contacts are closed and integrator output decreases. [Pg.494]

Pressure switches are used to energize and de-energize electrical circuits when the process pressure reaches their set points. The standard switch contact configurations are shown in Figure 3.143. The contacts are designated as normally open (N/O) and normally closed (N/C). In case of a single-pole double-throw (SPDT) switch, as the process pressure reaches the set point, the N/C contact opens and the common (C) side of the switch is closed to the contact designated as N/O. [Pg.478]

Thus, if L = 0.05 H and C = 100 pF, the maximum instantaneous voltage developed is 5366 V, which is sufficient to cause a spark to be struck across the switch contacts with consequent damage. [Pg.154]

Back to the standard s content doors and covers giving access to the interior of enclosures containing remotely operated circuits with switching contacts which can be made or broken by non-manual influences (e.g. electrical, mechanical, magnetic, electromagnetic, pneumatic, hydraulic and others) shall... [Pg.127]

Switching contacts shall have an additional housing before encapsulation. If the rated contact current exceeds 6 A, the additional housing shall be inorganic (glass, ceramics). [Pg.168]

Flameproof components (Fig. 6.100) show a body of insulating material, acting both as a mechanical support for terminals, magnetic coils, switching contacts, operating rods or spindles and as a flameproof enclosure for the... [Pg.264]

Pump suction pressure switch contacts opened. Break or leak in chlorine vacuum line piping. [Pg.427]

Use Springs, electrical switches, contact fingers, chains, fourdrinier wire. [Pg.984]

Electrical Equipment and Instruments. Electrical sparks produced during normal working of switches, contact breakers, motors, fuses, etc. can ignite dust layers and clouds. [Pg.792]

Patton ST, Voevodin AA, Vaia RA et al (2008) Nanoparticle liquids for surface modification and lubrication of MEMS switch contacts. J Microelectromech Syst 17 741-746... [Pg.234]

The arc resistance of a plastic is its ability to withstand the action of an electric are tending to form a conducting path across the surface. In applications where the material is subject to arcing, such as switches, contact bushes, and circuit breakers, resistance to arc is an important requirement. Arcing tends to produce a conducting carbonized path on the surface. [Pg.347]

It can also be a problem to run up the vacuum unit before full vacuum is achieved in the de-airing chamber. Visual control or, even better, a suitable vacuum gauge with switching contacts can prevent such problems. [Pg.304]

When the switch is opened the current stops flowing and, therefore, the magnetic flux collapses. The collapsing magnetic flux induces an e.m.f. into the coil and this voltage appears across the switch contacts. Tfie effect is known as self-inductance, or just inductance, and is one property of any coil. The unit of inductance is the henry (symbol H), to commemorate the work of the American physicist Joseph Henry (1797-1878), and a circuit is said to possess an inductance of 1 henry when an e.m.f. of 1 volt is induced in the circuit by a current changing at the rate of 1 ampere per second. [Pg.106]

When we open the switch of an inductive circuit such as an electric motor or fluorescent light circuit the magnetic flux collapses and produces an arc across the switch contacts. The arc is produced by the stored magnetic energy being discharged across the switch contacts. [Pg.107]

The circuit can be restored when the fault is removed by pressing the ON toggle. This latches the various mechanisms within the MCB and makes the switch contact. The toggle switch can also be used to disconnect the circuit for maintenance or isolation, or to test the MCB for satisfactory operation. [Pg.189]

A switch used on guard doors that is used to detect if the door is opened while the machine is running, and uses a coded actuator to prevent intentional defeat. Safety interlock switches use positive opening contacts, which ensure that the closed switching contact is forced open when the guard is opened, without reliance upon spring action. [Pg.261]


See other pages where Switch contacts is mentioned: [Pg.612]    [Pg.308]    [Pg.90]    [Pg.927]    [Pg.987]    [Pg.90]    [Pg.111]    [Pg.305]    [Pg.388]    [Pg.987]    [Pg.976]    [Pg.426]    [Pg.427]    [Pg.427]    [Pg.427]    [Pg.428]    [Pg.428]    [Pg.315]    [Pg.222]    [Pg.905]    [Pg.173]    [Pg.251]    [Pg.1145]    [Pg.28]    [Pg.570]    [Pg.363]    [Pg.94]   