Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Subject circular

We test the impact resistance of polymer plaques using the configuration shown in Fig. 8.8. We subject circular injection molded plaques to the shock of a falling weight with a hemispherical impacter. This test is also known as the Dart Drop Test . Samples can fail in a brittle or a ductile manner. Brittle samples often shatter. Ductile samples can split or a small disk may be punched out of their center. This test provides results that are analogous to those obtained from un-notched impact beam testing. [Pg.167]

The next question asked is whether there are any indications, from ab initio calculations, to the fact that the non-adiabatic transfonnation angles have this feature. Indeed such a study, related to the H3 system, was reported a few years ago [64]. However, it was done for circular contours with exceptionally small radii (at most a few tenths of an atomic unit). Similar studies, for circular and noncircular contours of much larger radii (sometimes up to five atomic units and more) were done for several systems showing that this feature holds for much more general situations [11,12,74]. As a result of the numerous numerical studies on this subject [11,12,64-75] the quantization of a quasi-isolated two-state non-adiabatic coupling term can be considered as established for realistic systems. [Pg.638]

Fig. 6. The envelope of the writhing number of closed circular DNA subject to torsional stress as a function of 7, as computed from Langevin trajectories. Data are from [31]. Fig. 6. The envelope of the writhing number of closed circular DNA subject to torsional stress as a function of 7, as computed from Langevin trajectories. Data are from [31].
As in tic, another method to vaUdate a chiral separation is to collect the individual peaks and subject them to some type of optical spectroscopy, such as, circular dichroism or optical rotary dispersion. Enantiomers have mirror image spectra (eg, the negative maxima for one enantiomer corresponds to the positive maxima for the other enantiomer). One problem with this approach is that the analytes are diluted in the mobile phase. Thus, the sample must be injected several times. The individual peaks must be collected and subsequently concentrated to obtain adequate concentrations for spectral analysis. [Pg.68]

Consider the design of a glass window for a vacuum chamber (Fig. 18.6). It is a circular glass disc of radius R and thickness f, freely supported in a rubber seal around its periphery and subjected to a uniform pressure difference Ap = 0.1 MPa (1 atmosphere). The pressure bends the disc. We shall simply quote the result of the stress analysis of such a disc it is that the peak tensile stress is on the low-pressure face of... [Pg.190]

Since wind is circular, it is frequently easier to interpret and visualize the frequency of wind flow subjectively by displaying a wind rose, that is, wind frequencies for each direction oriented according to the azimuth for that direction. Figure 21-8 is a wind rose showing both directional frequencies and wind speed frequencies by six classes from 3-hourly observations for a 5-year period (1965-1969) for O Hare Airport, Chicago. The highest frequencies are from the south and west, the lowest from the southeast and east. [Pg.357]

A circular polypropylene plate, 150 nun in diameter is simply supported around its edge and is subjected to a uniform pressure of 40 kN/m. If the stress in the material is not to exceed 6 MN/m, estimate a suitable thickness for the plate and the deflection, 6, after one year. The stress in the plate is given by... [Pg.159]

The torsion-tube test described by Whitney, Pagano, and Pipes [2-14] involves a thin circular tube subjected to a torque, T, at the ends as in Figure 2-29. The tube is made of multiple laminae with their fiber directions aligned either all parallel to the tube axis or all circumferentially. Reasonable assurance of a constant stress state through the tube thickness exists if the tube is only a few laminae thick. However, then serious end-grip difficulties can arise because of the flimsy nature of the tube. Usually, the thickness of the tube ends must be built up by bonding on additional layers to introduce the load so that failure occurs in the central uniformly stressed portion of the tube (recall the test specimen criteria). Torsion tubes are expensive to fabricate and require relatively sophisticated instrumentation. If the shearing strain y 2 is measured under shear stress t.,2, then... [Pg.99]

The common heater block shown in Fig. 19.23 can itself be subject to corrosion leading to different heat transfer conditions for different tubes, and in some later versions of the apparatus individual short heating jackets are used for each tube, which are heated with oil from either a steam-heated or electrically heated heat exchanger. This modification not only avoids corrosion problems but also obviates the necessity to machine a length of the outside of each tube to fit the semi-circular notches in the single heater block. The oil flow is adjusted to give an oil temperature of 95°C at each outlet. [Pg.1050]

There is usually more than one test method to determine a performance because each test has its own behavior and meaning. As an example there are different tests used to determine the abrasion resistance of materials. There is the popular Taber abrasion test. It determines the weight loss of a plastic or other material after it is subjected to abrasion for a prescribed number of the abrader disk rotations (usually 1000). The abrader consists of an idling abrasive speed controlled rotating wheel with the load applied to the wheel. The abrasive action on the circular specimen is subjected to a rotary motion. [Pg.297]

When the static pressure in a moving fluid is to be determined, the measuring surface must be parallel to the direction of flow so that no kinetic energy is converted into pressure energy at the surface. If the fluid is flowing in a circular pipe the measuring surface must be perpendicular to the radial direction at any point. The pressure connection, which is known as a piezometer tube, should terminate flush with the wall of the pipe so that the flow is not disturbed the pressure is then measured near the walls where the velocity is a minimum and the reading would be subject only to a small error if the surface were not quite parallel to the direction of flow. A piezometer tube of narrow diameter is used for accurate measurements. [Pg.234]

The convective and nucleate boiling heat transfer coefficient was the subject of experiments by Grohmann (2005). The measurements were performed in microtubes of 250 and 500 pm in diameter. The nucleate boiling metastable flow regimes were observed. Heat transfer characteristics at the nucleate and convective boiling in micro-channels with different cross-sections were studied by Yen et al. (2006). Two types of micro-channels were tested a circular micro-tube with a 210 pm diameter, and a square micro-channel with a 214 pm hydraulic diameter. The heat transfer coefficient was higher for the square micro-channel because the corners acted as effective nucleation sites. [Pg.301]

Although the total content of carbohydrate fractions of the three components is similar, as reported by Williams et al., 1990, it was found that protein-rich fractions have a significantly lower glucuronic acid content. Circular dichroism studies conducted on different GA fractions showed that only the AGP and GP components have a secondary structure (Renard et al., 2006). The AGP fraction was isolated by gel filtration chromatography and subjected to deglycosylation with hydrofluoric acid (HF) to separate the protein (Qi et al., 1991). About 400 amino acids were contained by the AGP protein fraction ( 33% are... [Pg.6]

It is still unclear what kind of radiation sources can lead to asymmetric reactions. Jeremy Bailey from the Anglo-Australian Observatory in Epping, Australia, investigated which astronomical objects could be considered radiation sources (Bailey et al., 1998 Bailey, 2001). It was possible in laboratory experiments to generate a small enantiomeric excess of some amino acids by using circularly polarized UV light (Norden, 1977). This asymmetric photolysis involves photochemical decomposition of both d- and L- enantiomers, but at different rates, so the more stable form tends to survive. This process must be subject to autocatalytic multiplication. [Pg.251]

Q. I would like to read you one excerpt from a circular sent out by the V.W. in December 1936 "Furthermore, a new process should be subject to secrecy if, through it, the self-sufficient military power of a possible enemy in case of war were considerably improved.. .." You knew about that instruction, didn t you ... [Pg.150]

Subjected to steady acceleration, a droplet is flattened gradually. When a critical relative velocity is reached, the flattened droplet is blown out into a hollow bag anchored to a nearly circular rim which contains at least 70% of the mass of the original droplet. Surface tension force is sufficient to allow the bag shape to develop. The bag, with a concave surface to the gas flow, is stretched and swept off in the downstream direction. The rupture of the bag produces a cloud of very fine droplets presumably via a perforation mode, and the rim breaks up into relatively larger droplets, although all droplets are at least an order of magnitude smaller than the initial droplet size. This is referred to as bag breakup (Fig. 3.10)T2861... [Pg.172]

Photochemically Triggered Induced Circular Dichroism in Liposomes When an optically inactive chromophore is subject to the effect of optically active environment, optical activity may be induced at the absorption wavelength of the optically inactive chromophore. This phenomenon of induced circular dichroism(ICD) is often observed in polypeptides bearing various achiral chromophores on the side chain( ). The strong chiral environment caused by the peptide helix structure is responsible for this. Distance from, and orientation to, the chiral field decide the degree of ICD appearing on the achiral chromophore. [Pg.216]

This is especially true in industrial and urban areas. Fig. 87 shows a paint containing Chrome Yellow, which was subjected to a test as described in Section 1.6.2.2 treatment with 1 N sulfuric acid for one hour at 70°C. The distinct color change on the circular test area is accompanied by a considerable gloss reduction. In the corresponding lead chromate-free system, it is only the binder that is affected, which reduces the gloss the color value on the other hand is retained. [Pg.157]


See other pages where Subject circular is mentioned: [Pg.35]    [Pg.1214]    [Pg.61]    [Pg.33]    [Pg.302]    [Pg.183]    [Pg.18]    [Pg.459]    [Pg.1865]    [Pg.673]    [Pg.167]    [Pg.416]    [Pg.112]    [Pg.217]    [Pg.82]    [Pg.213]    [Pg.46]    [Pg.248]    [Pg.755]    [Pg.79]    [Pg.79]    [Pg.286]    [Pg.59]    [Pg.437]    [Pg.111]    [Pg.392]    [Pg.516]    [Pg.176]    [Pg.69]    [Pg.103]    [Pg.41]   
See also in sourсe #XX -- [ Pg.131 , Pg.311 ]




SEARCH



© 2024 chempedia.info