Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stop program

Loop Observe results on spreadsheet. Stop program manually. [Pg.211]

DuPont undated. DuPont Stop Program. Available at htlp //www.training. dupont.com/dupont-stop/ (last accessed on 1 June 2014). [Pg.38]

MOO program stop (stops program - will start at same position if cycle start is pressed)... [Pg.178]

Some private-sector worksites such as the Dupont Corporation have successfully implemented an innovative written reporting system known as the Stop program, which has as its cornerstone basic hazard-recognition skills. A similar system may work well in your organization. [Pg.33]

To determine time dependent behaviours of the specimen up to 25 measurements in series with different time delays are possible. To prevent mistakes in application many help comments appear when inputs are necessary or differences between the calibration and the measurement are detected. All calibration conditions, a description for the specimen and results can be printed or saved by the hard disk. To reduce the input expenditure, the last configuration is made to current values when the program is stopped ore leave. [Pg.869]

A back end program essentially acts as a computational server for the front end. It receivcsinpiit, computes something, sendsit back to the front end and then looks for further input or commands from the front end. It can be used over and over for different cal-cii lation s. If it has been explicitly stopped, the Iron t end will start... [Pg.156]

The program contains a do loop that iterates the statements within the loop until the condition (A — 1)<0 is true. Try moving the do statement around in the program to see what changes in the output. Explain. If you encounter an infinite loop, True BASIC has a STOP statement to get you out. [Pg.6]

The implication of self-consistency is that the calculation is iterated until calculated properties (strictly, one selected property) remain constant on renewed iteration. Program SCF, however, stops calculating new matrix elements after 10 iterations. The assumption is that self-consistency will have been reached by then. [Pg.258]

Most programs will stop trying to converge a problem after a certain number of iterations. In a few rare cases, the wave function will converge if given more than the default number of iterations. [Pg.195]

Process simulators stop generally at the process specifications for the equipment. For the detailed mechanical design of the equipment, such as heat exchangers and distillation columns, stand-alone programs are often used. They make process calculations, size the equipment, calculate thermal and mechanical stresses, design mechanical support of the parts of the equipment, design inlet and outlet nozzles, etc. [Pg.77]

The original recipe adopted by the U.S. Government Synthetic Rubber Program was known as the "Mutual Recipe" and is shown iu Table 4. As can be seen, the reaction temperature was set at 50°C, which resulted iu 75% conversion to polymer iu about 12 h. The reaction was then stopped by addition of a "shortstop," such as 0.1 parts hydroquinone, which destroyed any residual catalyst (persulfate), and generated quiuone, which helped inhibit any further polymerisation. [Pg.468]

Cyclic nature of Implement mechanical integrity program batch process (e.g.,, Design equipment for easy replacement start/stop, thermal cycling). Possibil- Consider demand of cycling while designing ity of mechanical equipment and controls wear and tear. Possible loss of containment. ... [Pg.53]

Erequent start/stop Minimize frequent start/stop by proper sizing of of equipment may equipment (e.g. pump capacity) lead to equipment, Implement mechanical integrity program failure. Develop procedure to investigate causes for frequent reset of control Minimize frequent start/stop of equipment ... [Pg.53]

Canada, and Mexico (23). The National Atmospheric Deposition Program has established the nationwide sampling network of —100 stations in the United States. The sampler is shown in Fig. 14-9 with a wet collection container. The wet collection bucket is covered with a lid when it is not raining. A sensor for rain moves the lid to open the wet collector bucket and cover the dry bucket at the beginning of a rainstorm. This process is reversed when the rain stops. [Pg.213]

Calibrate the detector tube pump for proper volume measurement at least quarterly. Simply connect the pump directly to the bubble meter with a detector mbe in-line. Use a detector mbe and pump from the same manufacturer. Wet the inside of the 100 cc bubble meter with soap solution. For volume calibration, experiment to get the soap bubble even with the zero ml mark of the buret. For piston-type pumps, pull the pump handle all the way out (full pump stroke) and note where the soap bubble stops for bellows-type pumps, compress the bellows fully for automatic pumps, program the pump to take a full pump stroke. [Pg.249]

Exhibits 2-5 and 2-6 are modified sample lists of programs and elements for an actual company (here called Xmple, Inc.) drawn from the files of Arthur D. Little. These are in addition to the PSM requirements shown in Exhibit 2-4. You should develop similar lists for your company. These can usually be obtained from PSM and ESH manuals or the specialist staff who support the programs and elements. Be careful to make sure you understand the scope of each program, as the titles can sometimes be a little misleading. For example, spill response may cover only measures to be taken to stop further spillage, while containment and clean-up are covered under emergency response. [Pg.24]


See other pages where Stop program is mentioned: [Pg.224]    [Pg.457]    [Pg.387]    [Pg.33]    [Pg.246]    [Pg.224]    [Pg.457]    [Pg.387]    [Pg.33]    [Pg.246]    [Pg.500]    [Pg.156]    [Pg.157]    [Pg.228]    [Pg.323]    [Pg.156]    [Pg.157]    [Pg.48]    [Pg.309]    [Pg.338]    [Pg.339]    [Pg.2340]    [Pg.65]    [Pg.172]    [Pg.923]    [Pg.244]    [Pg.269]    [Pg.310]    [Pg.358]    [Pg.395]    [Pg.466]    [Pg.1150]   
See also in sourсe #XX -- [ Pg.33 ]




SEARCH



© 2024 chempedia.info