Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standard solutions Technique

Once again, we can use the standard solution technique for ordinary differential equations (Kreyszig, 1982), resulting in a solution. [Pg.154]

With the equivalent permeability of the gap known, the flow in the gap can be calculated using the standard solution techniques for the RTM process, with the flow velocity now given by Darcy s law with K given by this equivalent permeability. For less computational effort, one can obtain fairly... [Pg.366]

A fairly obvious variant of the structures discussed so far v ould be to include both vinylene and phenylene units in the polymer backbone, and a considerable number of such structures have been investigated. The parent of this group of polymers is poly(paraphenylene vinylene), which has been prepared by a number of different routes. Like polyacetylene and poly(paraphenylene), this polymer is insoluble and difficult to process again the most promising synthesis appears to be that proceeding via a processable precursor (see Figure 4.7). In this case the precursor polymer is a polyelectrolyte which can be processed via standard solution techniques and converted to the required product as and when desired. [Pg.126]

The solution Xh(t) of the linearized equations of motion can be solved by standard NM techniques or, alternatively, by explicit integration. We have experimented with both and found the second approach to be far more efficient and to work equally well. Its handling of the random force discretization is also more straightforward (see below). For completeness, we describe both approaches here. [Pg.247]

The standard Galerkin technique provides a flexible and powerful method for the solution of problems in areas such as solid mechanics and heat conduction where the model equations arc of elliptic or parabolic type. It can also be used to develop robust schemes for the solution of the governing equations of... [Pg.53]

Both equation 11 and the two-dimensional counterpart of equation 9 can be solved by several standard mathematical techniques, one of the more useful being that of conformal mapping. A numerical solution is often more practical for compHcated configurations. [Pg.89]

Eigure 11 illustrates the superior conductivity of P/M silver—nickel or silver—cadmium oxide contacts when compared with contacts made by standard melting techniques and formed from soHd-solution alloys. [Pg.190]

Although the most sensitive line for cadmium in the arc or spark spectmm is at 228.8 nm, the line at 326.1 nm is more convenient to use for spectroscopic detection. The limit of detection at this wavelength amounts to 0.001% cadmium with ordinary techniques and 0.00001% using specialized methods. Determination in concentrations up to 10% is accompHshed by solubilization of the sample followed by atomic absorption measurement. The range can be extended to still higher cadmium levels provided that a relative error of 0.5% is acceptable. Another quantitative analysis method is by titration at pH 10 with a standard solution of ethylenediarninetetraacetic acid (EDTA) and Eriochrome Black T indicator. Zinc interferes and therefore must first be removed. [Pg.388]

The reaction product of 4,4 -bismaleimidodiphenylmethane and 4,4 -diaminophenylmethane, known as Kerimide 601 [9063-71-2] is prepolymerized to such an extent that the resulting prepolymer is soluble in aprotic solvents such as /V-methy1pyrro1idinone [872-50-4] dimethylformamide [68-12-2] and the like, and therefore can be processed via solution techniques to prepreg. Kerim ide 601 is mainly used in glass fabric laminates for electrical appHcations and became the industry standard for polyimide-based printed circuit boards (32). [Pg.26]

Full quantitation is accomplished in the same manner as for most analytical instrumentation. This involves the preparation of standard solutions and matching of the matrix as much as possible. Since matrix interferences are usually minimized in ICPMS (relative to other techniques), the process is usually easier. [Pg.630]

The overall design process depends on the use of codes of practice and specifications, and to an increasing extent on computer-based techniques. The potential cost of delay is therefore a strong incentive to the use of standard solutions, compatible with the codes of practice , and to develop ways of using the computer to provide corrosion information and knowledge, or to improve prediction of corrosion behaviour. Note that both points relate to the use of existing knowledge, in the sense of an important conclusion of the Hoar Report. ... [Pg.6]

Polymerization thermodynamics has been reviewed by Allen and Patrick,323 lvin,JM [vin and Busfield,325 Sawada326 and Busfield/27 In most radical polymerizations, the propagation steps are facile (kp typically > 102 M 1 s l -Section 4.5.2) and highly exothermic. Heats of polymerization (A//,) for addition polymerizations may be measured by analyzing the equilibrium between monomer and polymer or from calorimetric data using standard thermochemical techniques. Data for polymerization of some common monomers are collected in Table 4.10. Entropy of polymerization ( SP) data are more scarce. The scatter in experimental numbers for AHp obtained by different methods appears quite large and direct comparisons are often complicated by effects of the physical state of the monomei-and polymers (i.e whether for solid, liquid or solution, degree of crystallinity of the polymer). [Pg.213]

The temperature differences found experimentally are less than expected theoretically because of heat losses within the apparatus. As indicated in the earlier part of this chapter, the experimental approach is to measure these temperature differences at a number of different concentrations and extrapolate to c = 0. The apparatus is calibrated using standard solutes of low relative molar mass, but despite this, the technique can be used on polymers up to of about 40 000. [Pg.83]

Situation Suppose a (monovalent) ionic species is to be measured in an aqueous matrix containing modifiers direct calibration with pure solutions of the ion (say, as its chloride salt) are viewed with suspicion because modifier/ion complexation and modifier/electrode interactions are a definite possibility. The analyst therefore opts for a standard addition technique using an ion-selective electrode. He intends to run a simulation to get a feeling for the numbers and interactions to expect. The following assumptions are made ... [Pg.230]

All three monomers were soluble In the chromatographic mobile phase and standard analytical techniques were used for calibration. Solutions containing known quantities of monomer were chromatographed to establish a peak area concentration relationship for the appropriate detector. The homopolymer of methylacrylate was also soluble In the mobile phase. Thus, both UV and refractometer detectors were calibrated for polymerized methylmethacrylate by chromatographing solutions of PM ... [Pg.79]

In most cases the only appropriate approach to model multi-phase flows in micro reactors is to compute explicitly the time evolution of the gas/liquid or liquid/ liquid interface. For the motion of, e.g., a gas bubble in a surrounding liquid, this means that the position of the interface has to be determined as a function of time, including such effects as oscillations of the bubble. The corresponding transport phenomena are known as free surface flow and various numerical techniques for the computation of such flows have been developed in the past decades. Free surface flow simulations are computationally challenging and require special solution techniques which go beyond the standard CFD approaches discussed in Section 2.3. For this reason, the most common of these techniques will be briefly introduced in... [Pg.230]

In order to apply RBL or GRAFA successfully some attention has to be paid to the quality of the data. Like any other multivariate technique, the results obtained by RBL and GRAFA are affected by non-linearity of the data and heteroscedast-icity of the noise. By both phenomena the rank of the data matrix is higher than the number of species present in the sample. This has been demonstrated on the PCA results obtained for an anthracene standard solution eluted and detected by three different brands of diode array detectors [37]. In all three cases significant second eigenvalues were obtained and structure is seen in the second principal component. [Pg.301]

Although the decomposition of a data table yields the elution profiles of the individual compounds, a calibration step is still required to transform peak areas into concentrations. Essentially we can follow two approaches. The first one is to start with a decomposition of the peak cluster by one of the techniques described before, followed by the integration of the peak of the analyte. By comparing the peak area with those obtained for a number of standards we obtain the amount. One should realize that the decomposition step is necessary because the interfering compound is unknown. The second approach is to directly calibrate the method by RAFA, RBL or GRAFA or to decompose the three-way table by Parafac. A serious problem with these methods is that the data sets measured for the sample and for the standard solution should be perfectly synchronized. [Pg.303]

Quantitation is performed by the calibration technique. A new calibration curve with anilide standard solutions is constructed for each set of analyses. The peak area or peak height is plotted against the injected amount of anilide. The injection volume (2 pL) should be kept constant as the peak area or peak height varies with the injection volume. Before each set of measurements, the GC or HPLC system should be calibrated by injection of standard solutions containing about 0.05-2 ng of anilide. Recommendation after constructing the calibration curve in advance, standard solutions and sample solutions are injected alternately for measurement of actual samples. [Pg.332]

Quantitative analysis is performed by the calibration technique. A new calibration curve with a standard solution of each diphenyl ether herbicides is constructed, plotting the peak area against the amount of standard solution injected. Each diphenyl ether herbicide in the sample is measured by using the peak area for each standard. Before each set of measurements, the GC and HPLC system is checked by injecting more than one standard solution containing ca 0.01-2 mg L of each compound. [Pg.457]

Quantitation is performed using the external standard calibration technique. The concentration of the calibration standard in solution is 1.0 qg mL . The calibration standard should be injected prior to injection of the treated samples and again after every second or third injection of treated samples. The analytical sequence should end with a calibration standard. The RSD of the calibration standards should be <10%. [Pg.507]

Quantitation is performed by the calibration technique. Construct a fresh calibration curve with pyriminobac-methyl standard solutions (individual isomer) for each set of analyses. [Pg.555]

Quantitation is performed by the calibration technique. Prepare a calibration curve by injecting pyrithiobac-methyl standard solutions, equivalent to 0.2,0.5,1.0,2.0,3.0 and 4.0 ng, into the gas chromatograph. Measure the heights of the peaks obtained. Plot the peak heights in millimeters against the injected amounts of pyrithiobac-methyl in nanograms. [Pg.562]


See other pages where Standard solutions Technique is mentioned: [Pg.47]    [Pg.437]    [Pg.264]    [Pg.127]    [Pg.759]    [Pg.395]    [Pg.461]    [Pg.431]    [Pg.741]    [Pg.1883]    [Pg.607]    [Pg.236]    [Pg.801]    [Pg.111]    [Pg.123]    [Pg.388]    [Pg.189]    [Pg.244]    [Pg.313]    [Pg.473]    [Pg.524]    [Pg.537]   
See also in sourсe #XX -- [ Pg.25 , Pg.144 , Pg.152 ]




SEARCH



76 Standard Solutions (Technique Class

Solution techniques

Solutions standard solution

Solutions standardization

Standard solution

Standardized Solutions

© 2024 chempedia.info