Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stability testing evaluation

Two types of laboratory tests were conducted to evaluate contaminant tests, a catalyst stability test and a high-conversion bromine product test. For catalyst stability testing, only a small amount of catalyst was used (1.5 g) to ensure incomplete conversion of the HBr. If a feed contaminant causes catalyst deactivation, it is apparent as an immediate decrease in conversion. If an excess of catalyst was used instead, even if deactivation occurred at the inlet of the bed, it may not be detected until the region of deactivation moves considerably downstream. This could take many hours or days. [Pg.307]

The introduction of 2-[4-(dimethylamino)phenylazo]benzoic acid into a silica sol allows the preparation of pH-sensitive doped coatings upon glass substrates. The behavior of this system was evaluated as the function of pH changes in liquid and gas media68. Optical absorption and sensitivity against pH were monitored by Vis spectroscopy. Chemical and mechanical stability tests carried out with coatings demonstrated that they were resistant enough to be use in sensor devices for pH measurements in laboratories. [Pg.368]

It should be emphasized that the results from RSST experiments use simplified calculation methods and give estimated values for stability and vent sizing. For large scale purposes, more dedicated and accurate measuring techniques may be needed for further hazard evaluation determinations. Due to the relatively recent development of this apparatus, comparison with other stability test methods is not yet comprehensive. [Pg.129]

There are numerous types of TLC testing done in the pharmaceutical industry, which are quantitative in nature. Release testing or purity evaluation, stability testing, and LOD are the three that will be addressed here. [Pg.436]

Those stages after the preclinical discovery and evaluation that involve technical development. These processes include formulation work, stability testing, scaling-up the compound for larger-scale synthesis, and providing analytical support. Clinical trials are not included in this definition. [Pg.992]

The Kolmogorov Smirnov test Closely related to the visual approach employed in Fig. 42, the KS test evaluates the equality of two distributions. Under the assumption that a saturation parameter has no impact on stability, its distribution within the stable subset is identical (in a statistical sense) to its initial distribution. Deviations between the two distributions, such as those shown in Fig. 42, thus indicate a dependency between the parameter and dynamic stability. [Pg.226]

In 55% of the cases, the accidents could have been foreseen by use of risk analysis, and in 35% of the cases by thermal stability testing. Different methods of stability testing were evaluated comparatively during the investigation of a runaway exothermic reaction which occurred during the preparation of a component mixture for a sealing composition in a 1200 1 reactor only DSC was effective in identifying the cause of the hazard. [Pg.305]

As with drugs and purified biomarkers, thermal- and photostability of botanical products are the factors that must be considered. Commercial dried extract and capsules of SJW were evaluated under harmonized test conditions (25). Photostability testing showed all the constituents to be photosensitive in the tested conditions. However, different opacity agents and pigments influenced the stability of the constituents. Amber containers had little effect on the photostability of the investigated constituents. Long-term thermal stability testing showed a shelf life of less than four months for hyperforins and hypericins, even when ascorbic and citric acids were added to the formulation. [Pg.61]

As shown above extracts of organoarsenicals obtained from cellulose ester filters and analyzed by the developed method suffer severely from lack of stability. To evaluate conclusively and also to find an appropriate filtering medium, experiments were performed to simultaneously test the stability of organoarsenicals on cellulose ester, Fluoropore, and Mitex filters. The experimental design is outlined in Figure 1. [Pg.390]

Q1B Stability Testing Photostability Testing of New Drug Substances and Products Basic testing protocol required to evaluate light sensitivity and stability of new drugs and products... [Pg.698]

The kind of test that is appropriate in the two cases is different in the first case, load should be increased until failure while in the second, some sort of deformation (or strain) control is appropriate. (A practical case of the latter is the Marshall stability test for evaluating the performance of asphalt concrete). In reality some combination of stress and strain capacity is required. [Pg.140]


See other pages where Stability testing evaluation is mentioned: [Pg.404]    [Pg.401]    [Pg.598]    [Pg.419]    [Pg.11]    [Pg.25]    [Pg.84]    [Pg.119]    [Pg.172]    [Pg.412]    [Pg.594]    [Pg.658]    [Pg.156]    [Pg.192]    [Pg.12]    [Pg.57]    [Pg.388]    [Pg.388]    [Pg.134]    [Pg.337]    [Pg.338]    [Pg.102]    [Pg.504]    [Pg.101]    [Pg.554]    [Pg.561]    [Pg.562]    [Pg.573]    [Pg.575]    [Pg.587]    [Pg.651]    [Pg.658]    [Pg.674]    [Pg.698]    [Pg.699]    [Pg.114]    [Pg.22]    [Pg.54]    [Pg.225]   
See also in sourсe #XX -- [ Pg.43 , Pg.44 ]




SEARCH



Evaluating Stability

Evaluation tests

Stability evaluation

Stability testing

© 2024 chempedia.info