Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Spectrometer Spectrophotometer

These filters are frequently used in applications requiring lower light intensities such as spectrometers, spectrophotometers, etc. Because they may age on storage (depending on their elements of composition), they should be checked on a regular basis, especially before use. The most frequent use of these filters in pharmaceutical photochemistry are as solar and window-glass filters for xenon and metal-halide lamp illuminators. [Pg.130]

Venus atmosphere is so dry that Earth-based and spacecraft measurements of the water-vapor abundance are extremely difficult. Historically, many of the in situ water-vapor measurements gave values much higher than the actual water-vapor content. However, reliable values are now available from several sources including the Pioneer Venus mass spectrometer, spectrophotometer experiments on Venera 11-14, Earth-based FTIR spectroscopy of Venus lower atmosphere on the nightside, and IR observations during the Galileo and Cassini flybys of Venus. [Pg.490]

FI on-line column separation and/or preconcentration have been applied to various detection systems, including atomic absorption and ICP spectrometers, spectrophotometers and electrochemical detectors. The basic components of the manifolds for different detection systems are quite similar, usually consisting of the following parts ... [Pg.103]

Finally, values of sx are directly proportional to transmittance for indeterminate errors due to fluctuations in source intensity and for uncertainty in positioning the sample cell within the spectrometer. The latter is of particular importance since the optical properties of any sample cell are not uniform. As a result, repositioning the sample cell may lead to a change in the intensity of transmitted radiation. As shown by curve C in Figure 10.35, the effect of this source of indeterminate error is only important at low absorbances. This source of indeterminate errors is usually the limiting factor for high-quality UV/Vis spectrophotometers when the absorbance is relatively small. [Pg.411]

Two common detectors, which also are independent instruments, are Fourier transform infrared spectrophotometers (FT-IR) and mass spectrometers (MS). In GC-FT-IR, effluent from the column flows through an optical cell constructed... [Pg.570]

This is primarily engaged in analysis of boiler water treatment matters and involves on-site studies of various problems and the chemical examination of corrosion products, boiler scales, etc. It can also carry out certain types of metallurgical, fuel and inorganic analysis. Normal wet methods of analysis coupled with a visible ultraviolet and atomic absorption spectrophotometer are used for a wide range of analytical applications. Equipment in use by the engineering insurers providing these services can include an ion chromatograph, spectrometer equipment, atomic... [Pg.148]

Kig. 5—1. Yortii American Philips (Philips Plodronics> -rav spectrometer converted Ion spectrophotometer for absorption measurements. (( ourlrsv o Hughes and Wilc/.ew ski, I roc.. Am. I droleiun hint., 30 M(III), 11.)... [Pg.131]

The intensity of absorbed radiation. Sunlight or room lights may alter the rate of a reaction. Usually this effect is to be avoided unless the object is to study photochemical effects. The light level in an optical spectrometer that uses monochromatic light is not likely to cause problems, but if white light strikes the sample, as in a diode-array spectrophotometer, this is a possibility. [Pg.9]

Co concentration was determined by spectrophotometer (Varian Cary 500) at 692 nm wave length, with the sample diluted with a 9 mol/L concentrated HCl solution. NO content in gas phase was obtained by an on-line Fourier transform infrared spectrometer (Nicolet E.S.P. 460 FT-IR) equipped with a gas cell and a quantitative package, Quant Pad. [Pg.231]

UV diffuse reflectance spectra of the titanates were obtained with a JASCO UVIDEC-660 spectrophotometer using a sintered alumina disc as a reference. Raman spectra were recorded at room temperature on a JASCO NR-1100 spectrometer. [Pg.144]

A modern spectrophotometer (UV/VIS, NIR, mid-IR) consists of a number of essential components source optical bench (mirror, filter, grating, Fourier transform, diode array, IRED, AOTF) sample holder detector (PDA, CCD) amplifier computer control. Important experimental parameters are the optical resolution (the minimum difference in wavelength that can be separated by the spectrometer) and the width of the light beam entering the spectrometer (the fixed entrance slit or fibre core). Modern echelle spectral analysers record simultaneously from UV to NIR. [Pg.301]

Melting points, measured in open capillary tubes using a Thomas-Hoover melting point apparatus, are uncorrected. Elemental analyses were performed by Galbraith Laboratories, Knoxville, Tennesee. % and 19C-NMR spectra were generally obtained with an IBM AF-100, if necessary the higher field Bruker WP-200 or AM-400 NMR spectrometer were employed. Chemical shifts are given in parts per million (ppm) on a a scale downfield from tetramethylsilane (TMS). Infrared spectra were recorded with a Perkln-Elmer 283 spectrophotometer. [Pg.8]

The quaternization kinetics were followed by 3H NMR spectroscopy using a JE0L FX-90Q NMR spectrometer. Solvolysis of p nitro-phenylacetate was followed by UV spectroscopy using a Hewlett Packard 8450 A diode array spectrophotometer. [Pg.75]

NMR spectra were recorded on a JEOL FX90Q (90 MHz) spectrometer. chemical shifts are reported relative to an internal standard of CHCI3 in CDCI3, while 13c chemical shifts are reported relative to the CDCI3 used as solvent. Infrared spectra were recorded on an IBM IR32 FTIR or a Perkin-Elmer 1330 IR spectrophotometer. Uv-visible spectra were obtained using a Varian DMS90 spectrophotometer. [Pg.251]

The C NMR spectra were obtained at 50.3 MHz on a Varian XL200 spectrometer. IR spectra were obtained on a Digilab F75-15 FTIR and Perkin-Elmer 1310 infra red spectrophotometer. [Pg.292]

In order to follow progress of elimination, reactions were also performed on thin films in a special sealed glass cell which permitted in situ monitoring of the electronic or infrared spectra at room temperature (23°C). Typically, the infrared or electronic spectrum of the pristine precursor polymer film was obtained and then bromide vapor was introduced into the reaction vessel. In situ FTIR spectra in the 250-4000 cm-- - region were recorded every 90 sec with a Digilab Model FTS-14 spectrometer and optical absorption spectra in the 185-3200 nm (0.39-6.70 eV) range were recorded every 15 min with a Perkin-Elmer Model Lambda 9 UV-vis-NIR spectrophotometer. The reactions were continued until no visible changes were detected in the spectra. [Pg.447]


See other pages where Spectrometer Spectrophotometer is mentioned: [Pg.102]    [Pg.23]    [Pg.24]    [Pg.25]    [Pg.102]    [Pg.23]    [Pg.24]    [Pg.25]    [Pg.1122]    [Pg.389]    [Pg.68]    [Pg.195]    [Pg.200]    [Pg.313]    [Pg.314]    [Pg.317]    [Pg.645]    [Pg.124]    [Pg.130]    [Pg.352]    [Pg.356]    [Pg.220]    [Pg.167]    [Pg.878]    [Pg.489]    [Pg.183]    [Pg.475]    [Pg.507]    [Pg.280]    [Pg.343]    [Pg.304]    [Pg.313]    [Pg.314]    [Pg.450]    [Pg.301]    [Pg.344]    [Pg.62]   


SEARCH



Spectrophotometers

© 2024 chempedia.info