Spectral analysis, collected

As in tic, another method to vaUdate a chiral separation is to collect the individual peaks and subject them to some type of optical spectroscopy, such as, circular dichroism or optical rotary dispersion. Enantiomers have mirror image spectra (eg, the negative maxima for one enantiomer corresponds to the positive maxima for the other enantiomer). One problem with this approach is that the analytes are diluted in the mobile phase. Thus, the sample must be injected several times. The individual peaks must be collected and subsequently concentrated to obtain adequate concentrations for spectral analysis. [Pg.68]

Elastic scattering is also the basis for Hdar, in which a laser pulse is propagated into a telescope s field of view, and the return signal is collected for detection and in some cases spectral analysis (14,196). The azimuth and elevation of the scatterers (from the orientation of the telescope), their column density (from the intensity), range (from the temporal delay), and velocity (from Doppler shifts) can be deterrnined. Such accurate, rapid three-dimensional spatial information about target species is useful in monitoring air mass movements and plume transport, and for tracking aerosols and pollutants (197). [Pg.318]

Figure 2. The spectral analysis of light collected by the fiber placed in a pH=7 phosphate-buffered distilled water sample. The spectriun shows the important interferences which must be eliminated to relate the fluorescence intensity to concentration. Figure 2. The spectral analysis of light collected by the fiber placed in a pH=7 phosphate-buffered distilled water sample. The spectriun shows the important interferences which must be eliminated to relate the fluorescence intensity to concentration.
Analysis result, n - the numerical or qualitative estimate of a physical, chemical, or quality parameter produced by applying the calibration model to the spectral data collected by an instmment according to specified measurement conditions. [Pg.509]

The simplest IR sensor would consist of a source, a sample interface and a detector. Although quite sensitive, such an arrangement would have no selectivity as any IR absorbing substance would cause an attenuation of the detected radiation. To get the selectivity that is a main driving force behind the application of IR systems, the radiation has to be spectrally analysed. This can be accomplished either by measurement at discrete wavelengths or, for multi-component sensors or samples containing (potentially) interfering substances, by full spectral analysis of the collected radiation. [Pg.141]

The above experiments are generally difficult to perform and the interpretation of the results may not necessarily be straightforward. The low abundance of the neutral products collected and the likelihood of mass spectral interference between reagents and products make these techniques applicable only to special cases. An independent approach to this problem has been proposed by Marinelli and Morton (1978) who have used an electron-bombardment flow reactor allowing in principle for larger collection of neutral products followed by glc and mass spectral analysis. [Pg.210]

Noninvasive glucose monitoring demands absolute glucose concentration measurements that match results obtained from conventional test strip technology. Absolute concentration measurements are complicated by the complexity of the sample matrix and variations of this matrix between individuals. Physical separations and selective chemical reactions are commonly used in analytical science to improve measurement accuracy. Such steps are not possible in a noninvasive analysis where all the selectivity information must be derived solely from the spectral information collected from the illuminated sample. [Pg.332]

Figure 4 A schematic representation of the experimentai approach for time-resoived XAS measurements. XAS provides local structural and electronic information about the nearest coordination environment surrounding the catalytic metal ion within the active site of a metalloprotein in solution. Spectral analysis of the various spectral regions yields complementary electronic and structural information, which allows the determination of the oxidation state of the X-ray absorbing metal atom and precise determination of distances between the absorbing metal atom and the protein atoms that surround it. Time-dependent XAS provides insight into the lifetimes and local atomic structures of metal-protein complexes during enzymatic reactions on millisecond to minute time scales, (a) The drawing describes a conventional stopped-flow machine that is used to rapidly mix the reaction components (e.g., enzyme and substrate) and derive kinetic traces as shown in (b). (b) The enzymatic reaction is studied by pre-steady-state kinetic analysis to dissect out the time frame of individual kinetic phases, (c) The stopped-flow apparatus is equipped with a freeze-quench device. Sample aliquots are collected after mixing and rapidly froze into X-ray sample holders by the freeze-quench device, (d) Frozen samples are subjected to X-ray data collection and analysis. Figure 4 A schematic representation of the experimentai approach for time-resoived XAS measurements. XAS provides local structural and electronic information about the nearest coordination environment surrounding the catalytic metal ion within the active site of a metalloprotein in solution. Spectral analysis of the various spectral regions yields complementary electronic and structural information, which allows the determination of the oxidation state of the X-ray absorbing metal atom and precise determination of distances between the absorbing metal atom and the protein atoms that surround it. Time-dependent XAS provides insight into the lifetimes and local atomic structures of metal-protein complexes during enzymatic reactions on millisecond to minute time scales, (a) The drawing describes a conventional stopped-flow machine that is used to rapidly mix the reaction components (e.g., enzyme and substrate) and derive kinetic traces as shown in (b). (b) The enzymatic reaction is studied by pre-steady-state kinetic analysis to dissect out the time frame of individual kinetic phases, (c) The stopped-flow apparatus is equipped with a freeze-quench device. Sample aliquots are collected after mixing and rapidly froze into X-ray sample holders by the freeze-quench device, (d) Frozen samples are subjected to X-ray data collection and analysis.
Preparation of urine samples. Urine was collected from Fischer 344 rats eight hours after dosing with the herbicide candidate. The urine was kept frozen until mass spectral analysis. After thawing, the urine was centrifuged for two minutes at 13,600 g before injection onto the liquid chromatograph. [Pg.93]


See other pages where Spectral analysis, collected is mentioned: [Pg.49]    [Pg.236]    [Pg.227]    [Pg.109]    [Pg.106]    [Pg.328]    [Pg.55]    [Pg.158]    [Pg.159]    [Pg.412]    [Pg.248]    [Pg.258]    [Pg.254]    [Pg.221]    [Pg.448]    [Pg.200]    [Pg.394]    [Pg.296]    [Pg.317]    [Pg.263]    [Pg.70]    [Pg.85]    [Pg.295]    [Pg.409]    [Pg.402]    [Pg.62]    [Pg.227]    [Pg.128]    [Pg.6318]    [Pg.136]    [Pg.267]    [Pg.37]    [Pg.332]    [Pg.134]    [Pg.1078]    [Pg.402]    [Pg.125]   