Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Source methods, comparison

Natural gas is by far the preferred source of hydrogen. It has been cheap, and its use is more energy efficient than that of other hydrocarbons. The reforming process that is used to produce hydrogen from natural gas is highly developed, environmental controls are simple, and the capital investment is lower than that for any other method. Comparisons of the total energy consumption (fuel and synthesis gas), based on advanced technologies, have been discussed elsewhere (102). [Pg.243]

The MPF and TMGM prospecting methods are based on the use of metallo-organics (fulvates and humates of metals) and oxides of iron and manganese (metals bound in oxides and hydroxides of iron and manganese). These forms of metals are the result of the secondary fixation of the movable fomis in rocks and have features such as (1) increased concentration coefficient and (2) only a weak bond with their initial geological source (in comparison, for example, with the movable forms collected in CHIM and MDE). Samples for MPF are taken from the humus-enriched layer at a depth of 5-10 cm, and samples for TMGM are taken from the sand-clay layer at a depth of 15-20 cm. [Pg.49]

Another form of random matrix-related interference is more rarely occurring gross errors, which typically are seen in the context of immunoassays and relate to unexpected antibody interactions (see interference section) Such an error will usually show up as an outlier in method comparison studies. A weU-known source is the occurrence of heterophilic antibodies. This is the background for the fact that outliers should be carefuUy considered and not just discarded from the data analysis procedure. Supplementary studies may help clarify such random matrix-related interferences and may provide specifications for the assay that limit its application in certain contexts (e.g., with regard to samples from certain patient categories). [Pg.370]

Uncertainty can be assessed in various ways, and often a combination of procedures is necessary. In principle, uncertainty can be judged directly from measurement comparisons or indirectly from an analysis of individual error sources according to the law of error propagation ( error budget )- Measurement comparison may consist of a method comparison study with a reference method based on patient samples according to the principles outlined previously or by measurement of certified matrix reference materials (CRMs). [Pg.399]

Ritter U., Myhr M.B., Vinge T., Aareskjold K. (1995) Experimental heating and kinetic models of source rocks comparison of different methods. Org. Geochem. 23, 1-9. [Pg.353]

The good agreement between the calculated and measured parameters validates this calculationat method for unreflected, low-enriched, fuel-solution systems with a central Cf neutron source. Further comparisons between measurement and calculations for a variety of solution systems are required before acceptance of this calculational method for these types of experiments. [Pg.810]

Gilev, K. V., Eremina, E., Yurkin, M. A., and Maltsev, V. P. (2010) Comparison of the discrete dipole approximation and the discrete source method for simulation of light scattering by red blood cells. Opt. Express, 18, 5681-5690. [Pg.127]

On the other hand, the NDT service business has evolved towards a more open market, in which the prime contractor requires a transparent access to the data provided by the supplier, in order to ensure the comparison of data obtained from different sources and at different periods of time. Existing fomiats are most of the time proprietary formats released by instrument manufacturers, generally dealing with a unique NDT method and not including complementary information on the acquisition consequently, they fail to meet these requirements. [Pg.922]

Dewar and his co-workers, as mentioned above, investigated the reactivities of a number of polycyclic aromatic compounds because such compounds could provide data especially suitable for comparison with theoretical predictions ( 7.2.3). This work was extended to include some compounds related to biphenyl. The results were obtained by successively compounding pairs of results from competitive nitrations to obtain a scale of reactivities relative to that of benzene. Because the compounds studied were very reactive, the concentrations of nitric acid used were relatively small, being o-i8 mol 1 in the comparison of benzene with naphthalene, 5 x io mol 1 when naphthalene and anthanthrene were compared, and 3 x io mol 1 in the experiments with diphenylamine and carbazole. The observed partial rate factors are collected in table 5.3. Use of the competitive method in these experiments makes them of little value as sources of information about the mechanisms of the substitutions which occurred this shortcoming is important because in the experiments fuming nitric acid was used, rather than nitric acid free of nitrous acid, and with the most reactive compounds this leads to a... [Pg.82]

Einely divided samples may be identified further by analyses of the graphite ash, and identification of the minerals associated with the graphite and comparison with graphites from known sources. Owing to its softness and opaqueness, most of the graphitic carbon must be removed from the sample before analysis by either method. There are two general ways of accomplishing this. [Pg.574]

At X-ray fluorescence analysis (XRF) of samples of the limited weight is perspective to prepare for specimens as polymeric films on a basis of methylcellulose [1]. By the example of definition of heavy metals in film specimens have studied dependence of intensity of X-ray radiation from their chemical compound, surface density (P ) and the size (D) particles of the powder introduced to polymer. Have theoretically established, that the basic source of an error of results XRF is dependence of intensity (F) analytical lines of determined elements from a specimen. Thus the best account of variations P provides a method of the internal standard at change P from 2 up to 6 mg/sm the coefficient of variation describing an error of definition Mo, Zn, Cu, Co, Fe and Mn in a method of the direct external standard, reaches 40 %, and at use of a method of the internal standard (an element of comparison Ga) value does not exceed 2,2 %. Experiment within the limits of a casual error (V changes from 2,9 up to 7,4 %) has confirmed theoretical conclusions. [Pg.104]

Gryning, S. E., and Lyck, E., "Comparison between Dispersion Calculation Methods Based on In-Situ Meteorological Measurements and Results from Elevated- Source Tracer Experiments in an Urban Area." National Agency of Environmental Protection, Air Pollution Laboratory, MST Luft - A40. Riso National Laboratory, Denmark, 1980. [Pg.318]

Figures Comparison of nuciear reactor and pulsed spaliation sources. For reactor sources (steady-state method), a narrow band of wavelengths is seiected with a monochromator crystal and the scattering angle (26,) Is varied to scan dspacings. Pulsed sources (time-of-flight method) use almost the entire avail-abie neutron spectrum, fix the scattering angie (26,), and simultaneousiy detect a neutron while determining its time of flight. Figures Comparison of nuciear reactor and pulsed spaliation sources. For reactor sources (steady-state method), a narrow band of wavelengths is seiected with a monochromator crystal and the scattering angle (26,) Is varied to scan dspacings. Pulsed sources (time-of-flight method) use almost the entire avail-abie neutron spectrum, fix the scattering angie (26,), and simultaneousiy detect a neutron while determining its time of flight.
In this chapter we focus our attention on some of the point sources of air emissions within different types of plant operations, along with the methods of abatement. Although we do not make direct comparisons between prevention and control methodologies until Chapter 6, the reader should gain an appreciation for the simplicity of applying pollution prevention as opposed to incorporating engineering controls in many situations. [Pg.53]

WASH-1400 is a fundamental document for PRA methodology. The data appendixes contain a great deal of useful information on methods of data assessment. A large number of sources for data are considered, and very general failure rate estimates will produce only gross approximations. Since the advent of data collection schemes across and within plants, the WASH-1400 data are solely useful as a constituent to a data aggregation process or as widely bounded figures that provide a basis for comparison. [Pg.125]

Marti, H. F. and R. A. Waller. An Exploratory Comparison of Methods for Combining Failure Rate Data from Different Data Sources. Report No. LA-7556-MS, Los Alamos Scientific Laboratory, 1987. [Pg.237]

The comparison of more than two means is a situation that often arises in analytical chemistry. It may be useful, for example, to compare (a) the mean results obtained from different spectrophotometers all using the same analytical sample (b) the performance of a number of analysts using the same titration method. In the latter example assume that three analysts, using the same solutions, each perform four replicate titrations. In this case there are two possible sources of error (a) the random error associated with replicate measurements and (b) the variation that may arise between the individual analysts. These variations may be calculated and their effects estimated by a statistical method known as the Analysis of Variance (ANOVA), where the... [Pg.146]

The industrial production of fatty acids on the basis of petrochemical raw materials is of secondary importance in comparison with their preparation from natural materials. Only short-chain or branched or odd-numbered carboxylic acids, for which natural sources don t exist, have to be prepared by different synthetic methods. [Pg.29]

Figure 2 Comparison of cloning and expression methods. In the conventional strategy (left), dehydrogenase genes obtained by PCR amplification of the original source DNAs are cloned into overexpression plasmids and verified by sequencing. Those with the desired structure are individually transformed into suitable host strains and the proteins are obtained, either as crude extracts or as purified samples. In the proposed streamlined approach (right), full-length dehydrogenase genes obtained by chemical synthesis are used directly in coupled transcription/translation reactions to obtain the proteins of interest. Figure 2 Comparison of cloning and expression methods. In the conventional strategy (left), dehydrogenase genes obtained by PCR amplification of the original source DNAs are cloned into overexpression plasmids and verified by sequencing. Those with the desired structure are individually transformed into suitable host strains and the proteins are obtained, either as crude extracts or as purified samples. In the proposed streamlined approach (right), full-length dehydrogenase genes obtained by chemical synthesis are used directly in coupled transcription/translation reactions to obtain the proteins of interest.

See other pages where Source methods, comparison is mentioned: [Pg.52]    [Pg.357]    [Pg.52]    [Pg.1984]    [Pg.360]    [Pg.565]    [Pg.20]    [Pg.504]    [Pg.215]    [Pg.317]    [Pg.291]    [Pg.118]    [Pg.508]    [Pg.162]    [Pg.19]    [Pg.265]    [Pg.235]    [Pg.148]    [Pg.732]    [Pg.247]    [Pg.567]    [Pg.24]    [Pg.228]    [Pg.32]    [Pg.102]    [Pg.1194]    [Pg.185]    [Pg.165]    [Pg.15]    [Pg.227]    [Pg.314]   
See also in sourсe #XX -- [ Pg.78 ]




SEARCH



Source methods

© 2024 chempedia.info