Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solvents liver

When the solvent is not the culture medium or water, the solvent, liver enzyme activation mixture and solvent and untreated controls are used as negative controls. [Pg.218]

Solvents Liver and kidney damage Provide adolescents... [Pg.408]

The toxicity of chloronaphthalenes requires that special attention and caution be used during their manufacture and use acne is the most common result of excessive skin exposure to them and the most frequendy affected areas are the face and neck (16). Liver damage has occurred in workers who have been exposed repeatedly to vapors, particulady to those of penta- and hexachloronaphthalene [1335-87-1] (17,18). Uses for the chlorinated naphthalenes include solvents, gauge and instmment duids, capacitor impregnants, components in electric insulating compounds, and electroplating stop-off compounds. [Pg.483]

Solutions in contact with polyvinyl chloride can become contaminated with trace amounts of lead, titanium, tin, zinc, iron, magnesium or cadmium from additives used in the manufacture and moulding of PVC. V-Phenyl-2-naphthylamine is a contaminant of solvents and biological materials that have been in contact with black rubber or neoprene (in which it is used as an antioxidant). Although it was only an artefact of the separation procedure it has been isolated as an apparent component of vitamin K preparations, extracts of plant lipids, algae, livers, butter, eye tissue and kidney tissue [Brown Chem Br 3 524 1967]. [Pg.3]

Chirazymes. These are commercially available enzymes e.g. lipases, esterases, that can be used for the preparation of a variety of optically active carboxylic acids, alcohols and amines. They can cause regio and stereospecific hydrolysis and do not require cofactors. Some can be used also for esterification or transesterification in neat organic solvents. The proteases, amidases and oxidases are obtained from bacteria or fungi, whereas esterases are from pig liver and thermophilic bacteria. For preparative work the enzymes are covalently bound to a carrier and do not therefore contaminate the reaction products. Chirazymes are available form Roche Molecular Biochemicals and are used without further purification. [Pg.520]

Gel permeation ehromatography (GPC)/normal-phase HPLC was used by Brown-Thomas et al. (35) to determine fat-soluble vitamins in standard referenee material (SRM) samples of a fortified eoeonut oil (SRM 1563) and a eod liver oil (SRM 1588). The on-line GPC/normal-phase proeedure eliminated the long and laborious extraetion proeedure of isolating vitamins from the oil matrix. In faet, the GPC step permits the elimination of the lipid materials prior to the HPLC analysis. The HPLC eolumns used for the vitamin determinations were a 10 p.m polystyrene/divinylbenzene gel eolumn and a semipreparative aminoeyano eolumn, with hexane, methylene ehloride and methyl tert-butyl ether being employed as solvent. [Pg.232]

Poly(DL-lactide) was used as the excipient in microspheres of CCNU, a nitrosourea, prepared by a solvent evaporation procedure (96,97). PLA-CCNU microspheres 3.0 pm in diameter were injected i.v. and leukemia cell survival was determined by spleen colony assay. A 100-fold decrease in leukemia cell survival was observed with the microspheres in both spleen and liver compared to untreated controls. Promising results were also obtained with Lewis lung carcinoma in mice. These studies showed that 2- to 4-ym microspheres were preferentially targeted to the lungs. [Pg.21]

In contrast, three European studies have found slight but statistically significant increases in cancer in workers exposed to trichloroethylene. A survey of Finnish workers exposed to primarily trichloroethylene found an association of limited statistical significance between exposure and incidence of stomach, liver, prostate, and lymphohematopoietic cancers (Antilla et al. 1995). However, the study did not reliably separate the effects of individual solvents, so attributing these cancers to trichloroethylene exposure alone was not possible. A significant association between workplace exposure to trichloroethylene and kidney cancer was found in a retrospective cohort study of German cardboard factory workers (Henschler et al. 1995). The... [Pg.59]

Differences among individuals can partially explain the differences in the before workshift and end of workshift levels of trichloroethylene and its metabolites. Increased respiration rate during a workday, induced by physical workload, has been shown to affect levels of unchanged trichloroethylene more than its metabolites, while the amount of body fat influences the levels of the solvent and its metabolites in breath, blood, and urine samples before workshift exposure (Sato 1993). Additionally, liver function affects measurements of exhaled solvent at the end of workshift increased metabolism of trichloroethylene will tend to decrease the amount exhaled after a workshift. Increased renal function would affect levels of TCA and trichloroethanol in blood before a workshift in the same way, but it probably would not affect urine values between the begiiming and the end of the workshift because of the slow excretion rate of TCA. [Pg.169]

Rasmussen K, Brogren CH, Sabroe S. 1993b. Subclinical affection of liver and kidney function and solvent exposure. Int Arch Occup Environ Health 64 445-448. [Pg.286]

The most critical decision to be made is the choice of the best solvent to facilitate extraction of the drug residue while minimizing interference. A review of available solubility, logP, and pK /pKb data for the marker residue can become an important first step in the selection of the best extraction solvents to try. A selected list of solvents from the literature methods include individual solvents (n-hexane, " dichloromethane, ethyl acetate, acetone, acetonitrile, methanol, and water ) mixtures of solvents (dichloromethane-methanol-acetic acid, isooctane-ethyl acetate, methanol-water, and acetonitrile-water ), and aqueous buffer solutions (phosphate and sodium sulfate ). Hexane is a very nonpolar solvent and could be chosen as an extraction solvent if the analyte is also very nonpolar. For example, Serrano et al used n-hexane to extract the very nonpolar polychlorinated biphenyls (PCBs) from fat, liver, and kidney of whale. One advantage of using n-hexane as an extraction solvent for fat tissue is that the fat itself will be completely dissolved, but this will necessitate an additional cleanup step to remove the substantial fat matrix. The choice of chlorinated hydrocarbons such as methylene chloride, chloroform, and carbon tetrachloride should be avoided owing to safety and environmental concerns with these solvents. Diethyl ether and ethyl acetate are other relatively nonpolar solvents that are appropriate for extraction of nonpolar analytes. Diethyl ether or ethyl acetate may also be combined with hexane (or other hydrocarbon solvent) to create an extraction solvent that has a polarity intermediate between the two solvents. For example, Gerhardt et a/. used a combination of isooctane and ethyl acetate for the extraction of several ionophores from various animal tissues. [Pg.305]

On-line dialysis also separates the analyte from tissue matrix based upon molecular size, but in this case, the sample extract is passed over a membrane filter through which the analyte (and other low molecular weight compounds) is diffused into a second solvent on the other side of the membrane filter. Usually, the second solvent is then concentrated on to an SPE column to minimize the dilution effect that is caused by the dialysis process. Agasoester used on-line dialysis to separate oxytetracycline from muscle, liver, milk, and egg tissue matrix components. A problem encountered with on-line dialysis is the inability of analyte molecules that are bound to proteins in the sample extract to pass through the membrane filter. Problems with membrane clogging are reduced with on-line dialysis compared with ultrafiltration because no external force is being applied to bring the analyte across the membrane filter. [Pg.310]

In general, the physical structure of the tissue must be broken down mechanically followed by an extraction procedure, before the sample can be analyzed. Homogenization using blenders, probe homogenizers, cell disrupters, sonicators, or pestle grinders is particularly useful for muscle, liver, and kidney samples. Regardless of the method used for tissue disruption, the pulse, volume of extraction solvent added, and temperature should be validated and standardized in order to ensure reproducible analytical results. During cell disruption, care should be taken to avoid heat build-up in the sample, because the analyte may be heat labile. [Pg.694]

Because of the possibility that the herbicide alachlor could adulterate food if either poultry or livestock consumed contaminated materials, Lehotay and Miller evaluated three commercial immunoassays in milk and urine samples from a cow dosed with alachlor. They found that milk samples needed to be diluted with appropriate solvents (1 2, v/v) to eliminate the matrix effect. One assay kit (selected based on cost) was also evaluated for use with eggs and liver samples from chickens. Egg and liver samples were blended with acetonitrile, filtered, and diluted with water. Linear calibration curves prepared from fortified egg and liver samples were identical... [Pg.695]

Crooks et al. developed a monensin immunoassay for the detection of residues in broiler livers. Livers were homogenized in aqueous acetonitrile, subsequently extracted with sodium hydroxide followed with hexane-diethyl ether, and the remaining solvent was evaporated before reconstitution in buffer for analysis. The LOD (mean-I-3 SD) was 2.9qgkg and the LOQ (mean- -6SD) was 4.6p.gkg . Incurred samples showed considerable animal-to-animal variation, but all samples were below the detection limit after 3 days. [Pg.706]


See other pages where Solvents liver is mentioned: [Pg.1384]    [Pg.1384]    [Pg.383]    [Pg.908]    [Pg.609]    [Pg.1384]    [Pg.1384]    [Pg.383]    [Pg.908]    [Pg.609]    [Pg.82]    [Pg.105]    [Pg.423]    [Pg.196]    [Pg.139]    [Pg.286]    [Pg.288]    [Pg.288]    [Pg.158]    [Pg.286]    [Pg.32]    [Pg.156]    [Pg.316]    [Pg.168]    [Pg.60]    [Pg.137]    [Pg.183]    [Pg.189]    [Pg.200]    [Pg.705]    [Pg.707]    [Pg.1156]    [Pg.1301]    [Pg.342]    [Pg.231]    [Pg.176]    [Pg.72]    [Pg.126]    [Pg.1229]    [Pg.225]   
See also in sourсe #XX -- [ Pg.41 ]




SEARCH



Liver solvent damage

Organic solvents liver

Solvents and the liver

© 2024 chempedia.info