Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Small samples

There are many large molecules whose mteractions we have little hope of detemiining in detail. In these cases we turn to models based on simple mathematical representations of the interaction potential with empirically detemiined parameters. Even for smaller molecules where a detailed interaction potential has been obtained by an ab initio calculation or by a numerical inversion of experimental data, it is usefid to fit the calculated points to a functional fomi which then serves as a computationally inexpensive interpolation and extrapolation tool for use in fiirtlier work such as molecular simulation studies or predictive scattering computations. There are a very large number of such models in use, and only a small sample is considered here. The most frequently used simple spherical models are described in section Al.5.5.1 and some of the more common elaborate models are discussed in section A 1.5.5.2. section Al.5.5.3 and section Al.5.5.4. [Pg.204]

New metliods appear regularly. The principal challenges to the ingenuity of the spectroscopist are availability of appropriate radiation sources, absorption or distortion of the radiation by the windows and other components of the high-pressure cells, and small samples. Lasers and synchrotron radiation sources are especially valuable, and use of beryllium gaskets for diamond-anvil cells will open new applications. Impulse-stimulated Brillouin [75], coherent anti-Stokes Raman [76, 77], picosecond kinetics of shocked materials [78], visible circular and x-ray magnetic circular dicliroism [79, 80] and x-ray emission [72] are but a few recent spectroscopic developments in static and dynamic high-pressure research. [Pg.1961]

Table 5-7. Small sample of interesting links in chemistry and chemoinforiTiatics. Table 5-7. Small sample of interesting links in chemistry and chemoinforiTiatics.
Both forms sublime very readily, even at room temperature a small sample on exposure to the air will completely volatilise in a short time, particularly on a warm day or if the sample is exposed to a gentle current of air. Hence the above method for rapid drying. A sample confined in an atmospheric desiccator over calcium chloride rapidly disappears as the vapour is adsorbed by the calcium chloride. A sample of the hexahydrate similarly confined over sodium hydroxide undergoes steady dehydration with initial liquefaction, for the m.p. of the hydrated-anhydrous mixture is below room temperature as the dehydration proceeds to completion, complete resolidification occurs. [Pg.150]

Absolute diethyl ether. The chief impurities in commercial ether (sp. gr. 0- 720) are water, ethyl alcohol, and, in samples which have been exposed to the air and light for some time, ethyl peroxide. The presence of peroxides may be detected either by the liberation of iodine (brown colouration or blue colouration with starch solution) when a small sample is shaken with an equal volume of 2 per cent, potassium iodide solution and a few drops of dilute hydrochloric acid, or by carrying out the perchromio acid test of inorganic analysis with potassium dichromate solution acidified with dilute sulphuric acid. The peroxides may be removed by shaking with a concentrated solution of a ferrous salt, say, 6-10 g. of ferrous salt (s 10-20 ml. of the prepared concentrated solution) to 1 litre of ether. The concentrated solution of ferrous salt is prepared either from 60 g. of crystallised ferrous sulphate, 6 ml. of concentrated sulphuric acid and 110 ml. of water or from 100 g. of crystallised ferrous chloride, 42 ml. of concentrated hydiochloric acid and 85 ml. of water. Peroxides may also be removed by shaking with an aqueous solution of sodium sulphite (for the removal with stannous chloride, see Section VI,12). [Pg.163]

Choice of solvent for recrystallisation. Obtain small samples (about 0 5 g.) of the following compounds from the storeroom (i) salicylic acid, (Li) acetanilide, (iii) m-dinitrobenzene, (iv) naphthalene, and (v) p-toluene-sulphonamide. Use the following solvents distilled water, methylated spirit, rectified spirit, acetone, benzene and glacial acetic acid. [Pg.232]

If the water insoluble mixture is a liquid, evaporate a small sample (say, 4 ml.) in an evaporating dish on a water bath in order to determine the amount of volatile components, if any. If the solvent distils at the temperature of the boihng water bath, it is advisable to distil ofiF this solvent on a water bath and to replace it by ether. [Pg.1095]

Note 1, A small sample was taken by means of a Pasteur pipette and the liquid was placed on the prism. Care should be taken that no evaporation of THF takes place this will give too high a n. ... [Pg.99]

HCeCCHjOCHs, n 1.3969, was obtained in 79-83% yield. A small sample was distilled b.p. 61°C (note 2). The product should be stored under nitrogen in the refrigerator. [Pg.237]

The molecular dipole moment is perhaps the simplest experimental measure of charge density in a molecule. The accuracy of the overall distribution of electrons in a molecule is hard to quantify, since it involves all of the multipole moments. Experimental measures of accuracy are necessary to evaluate results. The values for the magnitudes of dipole moments from AMI calculations for a small sample of molecules (Table 4) indicate the accuracy you may... [Pg.134]

The standard deviation cr may be estimated by calculating the standard deviation 5- drawn from a small sample set as follows ... [Pg.197]

Mitschele, J. Small Sample Statistics, /. Chem. Educ. 1991, 68, 470M73. [Pg.102]

Laser desorption is commonly used for pyrolysis/mass spectrometry, in which small samples are heated very rapidly to high temperatures to vaporize them before they are ionized. In this application of lasers, very small samples are used, and the intention is not simply to vaporize intact molecules but also to cause characteristic degradation. [Pg.12]

Column Si. Size-exclusion chromatography columns are generally the largest column on a process scale. Separation is based strictly on diffusion rates of the molecules inside the gel particles. No proteins or other solutes are adsorbed or otherwise retained owing to adsorption, thus, significant dilution of the sample of volume can occur, particularly for small sample volumes. The volumetric capacity of this type of chromatography is determined by the concentration of the proteins for a given volume of the feed placed on the column. [Pg.50]

In the case of a panel painting, a small sample of the wooden support can be removed, from which a microscopic specimen can be prepared in order to identify the wood used for the panel. [Pg.420]

Fire test methods attempt to provide correct information on the fire contribution of a product by exposing a small sample to conditions expected in a fire scenario. Methods can be viewed in two ways the first entails the strategy of the fire test, ignition resistance or low flammabiUty once ignited the second addresses the test specimen, a sample representative of the product or a sample of a material that might be used in the product. Fire science has progressed markedly since the older test methods were developed and it is known that the basis for many of these tests is doubthil. Results from older tests must be used with great care. [Pg.451]

Microscopy (qv) plays a key role in examining trace evidence owing to the small size of the evidence and a desire to use nondestmctive testing (qv) techniques whenever possible. Polarizing light microscopy (43,44) is a method of choice for crystalline materials. Microscopy and microchemical analysis techniques (45,46) work well on small samples, are relatively nondestmctive, and are fast. Evidence such as sod, minerals, synthetic fibers, explosive debris, foodstuff, cosmetics (qv), and the like, lend themselves to this technique as do comparison microscopy, refractive index, and density comparisons with known specimens. Other microscopic procedures involving infrared, visible, and ultraviolet spectroscopy (qv) also are used to examine many types of trace evidence. [Pg.487]

Immersion electrodes are the most common glass electrodes. These are roughly cylindrical and consist of a barrel or stem of inert glass that is sealed at the lower end to a tip, which is often hemispherical, of special pH-responsive glass. The tip is completely immersed in the solution during measurements. Miniature and microelectrodes are also used widely, particularly in physiological studies. Capillary electrodes permit the use of small samples and provide protection from exposure to air during the measurements, eg, for the determination of blood pH. This type of electrode may be provided with a water jacket for temperature control. [Pg.466]

The concentration [MB] constantly experiences tiny fluctuations, the duration of which can determine linewidths. It is also possible to adopt a traditional kinetic viewpoint and measure the time course of such spontaneous fluctuations directly by monitoring the time-varying concentration in an extremely small sample (6). Spontaneous fluctuations obey exactly the same kinetics of return to equiUbrium that describe relaxation of a macroscopic perturbation. Normally, fluctuations are so small they are ignored. The relative ampHtude of a fluctuation is inversely proportional to the square root of the number of AB entities being observed. Consequently, fluctuations are important when concentrations are small or, more usehiUy, when volumes are tiny. [Pg.513]

White phosphoms is a soft waxy soHd often compared to paraffin wax. Small samples under water can be cut with a knife with some difficulty. [Pg.347]

ISO 871, Temperature of Evolution ofFlammable Gases (Decomposition Temperature) from a Small Sample of Pulveri yed Material, ISO, Geneva, Switzedand, 1994. [Pg.160]


See other pages where Small samples is mentioned: [Pg.67]    [Pg.112]    [Pg.1440]    [Pg.1561]    [Pg.1583]    [Pg.1781]    [Pg.1791]    [Pg.1916]    [Pg.1939]    [Pg.2242]    [Pg.218]    [Pg.181]    [Pg.137]    [Pg.82]    [Pg.92]    [Pg.93]    [Pg.44]    [Pg.563]    [Pg.135]    [Pg.100]    [Pg.416]    [Pg.418]    [Pg.423]    [Pg.487]    [Pg.192]    [Pg.199]    [Pg.311]    [Pg.546]    [Pg.84]    [Pg.133]   
See also in sourсe #XX -- [ Pg.99 ]

See also in sourсe #XX -- [ Pg.99 ]




SEARCH



A Small Sampling of Rules

Confidence limits of the mean for small samples

Counting apparatus, small sample

Dating small-sample

Estimation of Population Parameters from Small Samples

Infrared microspectroscopy small-size samples

Plastics in the French media a small sample

Problem of small sample size

Sample small-molecule MALDI

Sequencing with small samples

Small Sample Distributions

Small Sample NMR Studies

Small sample NMR

Small sample mass

Small sample preparation

Small sample sizes

Small volume sampling and

Small-animal tissue samples

Support Vector Machine Data Processing Method for Problems of Small Sample Size

Ultratrace Analysis of Long-lived Radionuclides in Very Small Sample Volumes

© 2024 chempedia.info