Sensor spacing

As a consequence, in a sensor space of dimension N the effective dimension of the sub-space occupied by the data is less than N. This dimension can be precisely evaluated using algorithms developed to describe dynamic systems. An example is the correlation distance that allows evaluating the fractional dimensionality of a data-set [16]. Correlation distance provides an independent way to evaluate the expected reduction of dimension. [Pg.154]

Statistical properties of a data set can be preserved only if the statistical distribution of the data is assumed. PCA assumes the multivariate data are described by a Gaussian distribution, and then PCA is calculated considering only the second moment of the probability distribution of the data (covariance matrix). Indeed, for normally distributed data the covariance matrix (XTX) completely describes the data, once they are zero-centered. From a geometric point of view, any covariance matrix, since it is a symmetric matrix, is associated with a hyper-ellipsoid in N dimensional space. PCA corresponds to a coordinate rotation from the natural sensor space axis to a novel axis basis formed by the principal... [Pg.154]

Geometrically, this means sectioning the sensor space with straight lines, each bisecting the space. The result is a partitioning of the space into volumes, each defining one class. Considering a set P of experimental data, the previous set of equations can be written in a compact matrix form as ... [Pg.159]

Figure 5.13 Correlation function with sensor spacing equal to L in the transverse direction at four locations. Figure 5.13 Correlation function with sensor spacing equal to L in the transverse direction at four locations.
The various stages in the signal processing of an electronic nose system are illustrated in Figure 11 in which the signals generated from an array of sensors (or, for example, pseudo-sensors in a mass spectrometer) are first pre-processed and then fed in to a pattern analyser. In other words the n dimension vector in sensor space is transformed into feature space (a process called feature extraction) and then identified using some form of pattern classifier. [Pg.19]

The persistence of flow disturbance can be measured through space correlation, with increasing spacing between the sensors. For the coal/oil slurry with 60 wt.% coal, cross-correlations were measured with various sensor spacings. Figure 5-20 is a composite of three cross-correlation functions. A... [Pg.183]

Installation of solar panels is required to charge the onboard batteries that are providing the electrical power to various electronics devices, stabilizing and attitude control sensors, space parameter monitoring instrument, lighting, and a host of other electrical systems that are vital in maintaining the desired performance of the satellite or spacecraft over the intended mission duration. [Pg.49]

The point in US image A is first scaled by S. It is mapped in sensor space by the rigid transformation Tf then into physical space by Tf That is X the point reported by EM tracking. We establish equation between the image point set and the physical point set given by formula ... [Pg.717]

Dynamic explosion detectors use a piezoresistive pressure sensor installed behind the large-area, gas-tight, welded membrane. To ensure optimum pressure transference from the membrane to the active sensor element, the space between the membrane and the sensor is filled with a special, highly elastic oil. The construc tion is such that the dynamic explosion detec tor can withstand overpressures of 10 bar without any damage or effect on its setup characteristic. The operational range is adjustable between 0 and 5 bar abs. Dynamic explo-... [Pg.2328]

Electric Field Meter These meters are calibrated to indicate the polarity and magnitude of the electric field (V/m) at the sensor. They should have only one calibrated meter/surface spacing and should be... [Pg.2334]

Limited Data First, plant data are limited. Unfortunately, those easiest to obtain are not necessarily the most useful. In many cases, the measurements that are absolutely required for accurate model development are unavailable. For those that are available, the sensitivity of the parameter estimate, model evaluation, and/or subsequent conclusion to a particiilar measurement may be very low. Design or control engineers seldom look at model development as the primaiy reason for placing sensors. Further, because equipment is frequently not operated in the intended region, the sensitive locations in space and time have shifted. Finally, because the cost-effectiveness of measurements can be difficult to justify, many plants are underinstru-mented. [Pg.2550]

Electrochemistry plays an important role in the large domain of. sensors, especially for gas analysis, that turn the chemical concentration of a gas component into an electrical signal. The longest-established sensors of this kind depend on superionic conductors, notably stabilised zirconia. The most important is probably the oxygen sensor used for analysing automobile exhaust gases (Figure 11.10). The space on one side of a solid-oxide electrolyte is filled with the gas to be analysed, the other side... [Pg.454]

Factory-constructed ventilation systems are constructed in a compact manner. Frequently, due to the smaller-space installation, inspection and maintenance of the sensors can be difficult. In ducts, deviations from the real... [Pg.778]

Usually this type of anemometer does not provide information on the flow direction. Vice versa, the. sensors are made as independent of the flow direction as possible—omnidirectional. This is an advantage for free-space ventilation measurements, as the flow direction varies constantly and a direction-sensitive anemometer would be difficult to use. Naturally, no sensor is fully omnidirectional, but satisfactory constructions are available. Due to the high sensor thermal inertia, this type of anemometer is unsuitable for high-frequency flow fluctuation measurement. They can be used to monitor low-frequency turbulence up to a given cut-off frequency, which depends on the dynamic properties of the instrument. [Pg.1154]

Errors related to velocity measurement instruments have different origins depending on the measurement principle. The most important of these have been covered in previous sections. One common source of error for all instruments is the disturbance of the flow field by the sensor/meter or the person carrying out the measuring. The influence of the sensor in an open space is usually... [Pg.1156]

Direct control A sy.stem controlled by a sensor that detects levels of indoor contaminants within the space... [Pg.1450]

Local control module directly wired to sensors and actuators (e.g., equipment to control space conditioning, such as pumps and fans) ... [Pg.465]

Environmentally Responsive Work-stations (ERWs). Workers in open-office areas have direct, individual control over both the temperature and air-flow. Radiant heaters and vents are built directly into their furniture and are controlled by a panel on their desks, which also provides direct control of task lighting and of white noise levels (to mask out nearby noises). A motion sensor in each ERW turns it off when the worker leaves the space, and brings it back on when he or she returns. [Pg.671]

Plastics will continue to be required in space applications from rockets to vehicles for landing on other planets. The space structures, reentry vehicles, and equipment such as antennas, sensors, and an astronaut s personal communication equipment that must operate outside the confines of a spaceship will encounter bizarre environments. Temperature extremes, thermal stresses, micrometeorites, and solar radiation are sample conditions that are being encountered successfully that include the use of plastics. [Pg.108]

The idea of using propagation of intensity to measure wavefront errors is applied more direetly in the eurvature sensor. Conceptually, the irradiance is measured at two planes which are equally spaced about the telescope focus and the normalized difference in intensity obtained. [Pg.190]


See other pages where Sensor spacing is mentioned: [Pg.153]    [Pg.154]    [Pg.121]    [Pg.123]    [Pg.123]    [Pg.124]    [Pg.124]    [Pg.125]    [Pg.313]    [Pg.153]    [Pg.154]    [Pg.121]    [Pg.123]    [Pg.123]    [Pg.124]    [Pg.124]    [Pg.125]    [Pg.313]    [Pg.62]    [Pg.250]    [Pg.249]    [Pg.291]    [Pg.123]    [Pg.465]    [Pg.321]    [Pg.432]    [Pg.361]    [Pg.326]    [Pg.107]    [Pg.234]    [Pg.1144]    [Pg.371]    [Pg.671]    [Pg.902]    [Pg.440]    [Pg.1133]    [Pg.400]    [Pg.108]   
See also in sourсe #XX -- [ Pg.123 , Pg.124 ]