Selected duties

Laser SNMS requires the operation with properly selected duty cycles that control the delay times between the primary ion pulse, a pulsed extraction voltage for separating the secondary ions from post-ionized neutrals, and the firing of the postionizing laser pulse. Such duty cycles have, in addition, to be synchronized with the stepwise motion of the pulsed primary ion beam across the sample surface in the microprobe mode of laser SNMS. The selection of appropriate duration and decay times of the ion and laser pulses, of the laser intensity, and beam shape is important to make the photoion yields independent on the sputtered particle velocities. The detection volume must be matched to the entrance ion optics of the TOP such that it becomes independent of the individual ionization process. Usually, laser intensities in the range from 10 to lO Wcm are applied. While the particle density in the detection volume is monitored at small laser intensities, the particle flux is measured at high photon densities. [Pg.4677]

Issues In determining selected duties in a rehabilitation programme (or plan)... [Pg.500]

Variable Air Flow Fans. Variable air flow fans are needed ia the process iadustry for steam or vapor condensing or other temperature critical duties. These also produce significant power saviags. Variable air flow is accompHshed by (/) variable speed motors (most commonly variable frequency drives (VFDs) (2) variable pitch fan hubs (J) two-speed motors (4) selectively turning off fans ia multiple fan iastaHations or (5) variable exit louvers or dampers. Of these methods, VFDs and variable pitch fans are the most efficient. Variable louvers, which throttle the airflow, are the least efficient. The various means of controlling air flow are summarized ia Table 3. [Pg.111]

Performance Curves. Pan manufacturers furnish fan performance curves for each type fan available. These are typically based on 61 m/s (12,000 ft/min) tip speed and 1.20 kg/m (0.075 lb /ft ) density. To select a fan for a specific duty requires knowledge of the flow, static pressure resistance, and density of the actual operating conditions. Usually the fan diameter is known as well as some idea of operating speed a 61 m/s tip speed can often be assumed. [Pg.112]

Because each effect of an evaporator produces almost as much vapor as the amount it condenses, the total evaporation accompHshed per unit of prime steam, or steam economy, iacreases ia almost direct proportioa to the number of effects used. The total heat load is also spHt up betweea the effects so that each effect has a much lower heat duty than a single effect for the same total evaporation load. However, the total available AT is also spHt up similarly so that each effect of a multiple effect requites about as much heating surface as a single effect operating over the same total temperature difference. Thus ia selecting the number of effects to use ia any iastallatioa, steam cost savings and capital cost of effects have to be balanced. Even before... [Pg.475]

The thermal duty here is the opposite of solidification operations. The indirect heat-transfer equipment suitable for one operation is not suitable for the other because of the material-handling rather than the thermal aspects. Whether the temperature of transformation is a definite or a ranging one is of little importance in the selection of equipment for fusion. The burden is much agitated, but the beds are deep. [Pg.1091]

Example 4 Calculation of the BP Method Use the BP method with the SRK eqiiation-of-state for K values and enthalpy departures to compute stage temperatures, interstage vapor and hqiiid flow rates and compositions, and rehoiler and condenser duties for the light-hydrocarhon distdlation-coliimn specifications shown in Fig. 13-51 with feed at 260 psia. The specifications are selected to obtain three products, a vapor distillate rich in Cri and C3, a vapor side-stream rich in n-C4, and a bottoms rich in n-C and n-Cg. [Pg.1284]

TTiis is a severe duty for the switching contactors as they have to endure repeated arcing of the interrupting contacts every time they make or break. (Select only AC-4 duty contactors see Section 12.10.)... [Pg.161]

The rating of current-carrying devices and components should be selected according to the continuous current they have to carry and the duty they have to perform. Deratings, depending upon the service conditions, should also be applied when deciding their continuous current... [Pg.371]

I Shunt reactors These are provided as shown in Figure 24.23 to compensate for the distributed lumped capacitances, C , on EHV networks and also to limit temporary overvoltages caused during a load rejection, followed by a ground fault or a phase fault within the prescribed steady-state voltage limits, as noted in Table 24.3. They ab.sorb reactive power to offset the charging power demand of EHV lines (Table 24.2, column 9). The selection of a reactor can be made on the basis of the duty it has to perform and the compensation required. Some of the different types of reactors and their characteristics are described in Chapter 27. [Pg.798]

Such types of loads may require special design of capacitor elements and their dielectric impregnation, cooling arrangement, size of shell or surface treatment. For all these applications therefore it is important to know the actual operating conditions, behaviour and characteristic of the load and its duty cycle before selecting the capacitors. [Pg.818]

We have summarized in Table 25.2 the basic parameters to select the correct type of components for capacitor duty. [Pg.818]

Selecting the SMPS controller IC. The important factors within this application that affect the choice of switching power supply controller IC are MOSFET driver needed (totem-pole driver), single-ended output, 50 percent duty cycle limit desired, and current-mode control desired. The popular industry choice that meets these needs is the UC3845B. [Pg.117]

As seen in Section 4.1, the major types of losses are the conduction and switching losses. Conduction losses are addressed by selecting a better power switch or rectifier with a lower conduction voltage. The synchronous rectifier can be used to reduce the conduction loss of a rectifier, but it can only be used for forward-mode topologies, and excludes the discontinuous boost-mode converters. The synchronous rectifier will improve the efficiency of a power supply about one to six percent depending upon the average operating duty cycle of the supply. For further improvements, other techniques must be pursued. [Pg.144]

Table 15.1 Selected Operator duties under the Carriage of Dangerous Goods by Road Regulations 1996 ... Table 15.1 Selected Operator duties under the Carriage of Dangerous Goods by Road Regulations 1996 ...
Cooling tower fan motors must be properly selected for long life and trouble free operation. In addition, it is important to match the motor s enclosure to the application. Motors in draw through applications that are mounted directly in the air stream, for example, experience tough duty and must be of the totally enclosed type. Motors are categorized as follows ... [Pg.80]

The actual number of trays needed for a particular separation duty depends on the efficiency of the plate, and the packings if they are used. Thus, any factors that cause a decrease in tray efficiency will also change the performance of the colunm. Tray efficiencies are affected by such factors as fouling, wear and tear and corrosion, and the rates at which these occur depends on the properties of the liquids being processed. Thus the proper materials of construction must be selected for tray construction. [Pg.180]

Employers will need to select how many different emergency preparedness or third lines of defense they plan to have, develop the necessary emergency plans and procedures, appropriately train employees in their emergency duties and responsibilities, and then implement these lines of defense. [Pg.243]

Risk depends on toxicity, design, and the competence of management at each site. Thus, management is responsible for hardware, work practices, and the selection, training, duties, and... [Pg.432]

The designer must fully appreciate the correct fan selection, by ensuring that its duty meets the requirements of the task for which it is intended. [Pg.742]


See other pages where Selected duties is mentioned: [Pg.196]    [Pg.319]    [Pg.500]    [Pg.317]    [Pg.196]    [Pg.319]    [Pg.500]    [Pg.317]    [Pg.6]    [Pg.433]    [Pg.105]    [Pg.288]    [Pg.209]    [Pg.153]    [Pg.160]    [Pg.1340]    [Pg.2371]    [Pg.51]    [Pg.63]    [Pg.65]    [Pg.105]    [Pg.134]    [Pg.312]    [Pg.545]    [Pg.614]    [Pg.221]    [Pg.173]    [Pg.133]    [Pg.413]    [Pg.461]    [Pg.67]    [Pg.114]   