Samples hquids

This analyser is a computer-controlled automated batch analyser, using a stop-flow principle to analyse for pH, conductivity, turbidity and colour. TTie principle of analysis for each module is based on the recommended methods as detailed in the Examination of Waters and Associated Materials issued by the Standing Committee of Analysts of the Department of the Environment. The temperature of the sample hquid flow is measured in order that temperature-compensated results of pH and conductivity can be quoted. [Pg.225]

Fig. 10.11. Polarizing optical microscope. ( Right) The microscope. ( Left) The path of incident somce light through polarizer, birefringent sample (hquid crystals), and... Fig. 10.11. Polarizing optical microscope. ( Right) The microscope. ( Left) The path of incident somce light through polarizer, birefringent sample (hquid crystals), and...
Filling the insert with silanized glass wool has proved effective for the absorption of the sample hquid and for rapid heat exchange. However, the glass wool clearly contributes to enlarging the active surface area of the injector and should therefore be used only in the analysis of noncritical compounds (alkanes, chlorinated hydrocarbons, etc.). For the injection of polar or basic components special care is required keeping the glass wool deactivated by frequent replacements, an empty deactivated insert is recommended. [Pg.119]

Heat a mixture of 15 g. of p-nitroacetanilide and 75 ml. of 70 per cent, sulphuric acid (1) under a reflux water condenser for 20-30 minutes or until a test sample remains clear upon dilution with 2-3 times its volume of water. The p-nitroaniline is now present in the hquid as the sulphate. Pour the clear hot solution into 500 ml. of cold water and precipitate the p-nitroanihne by adding excess of 10 per cent, sodium hydroxide solution or of concentrated ammonia solution. When cold (cool the mixture in ice water, if necessary), filter the yellow crystalline precipitate at the pump, wash it well with water, and drain thoroughly. Recrystallise it from a mixture of equal volumes of rectified (or methylated) spirit and water or from hot water. Filter, wash and dry. The yield of p-nitroanihne, m.p, 148°, is 11 g. [Pg.581]

Thin-Layer Chromatography. Chiral stationary phases have been used less extensively in tic as in high performance Hquid chromatography (hplc). This may, in large part, be due to lack of avakabiHty. The cost of many chiral selectors, as well as the accessibiHty and success of chiral additives, may have inhibited widespread commerciali2ation. Usually, nondestmctive visuali2ation of the sample spots in tic is accompHshed using iodine vapor, uv or fluorescence. However, the presence of the chiral selector in the stationary phase can mask the analyte and interfere with detection (43). [Pg.62]

Hydroquinone can be deterrnined spectrophotometricaHy at 292 nm in methanol after a sample is evaporated to dryness to remove the interference of acrolein. An alternative method is high performance Hquid chromatography on 10-p.m LiChrosorb RP-2 at ambient temperature with 2.0 mL/min of 20%(v/v) 2,2,4-trimethylpentane, 79.20% chloroform, and 0.80 % methanol with uv detection at 292 nm. [Pg.124]

The crystal stmcture of glycerides may be unambiguously determined by x-ray diffraction of powdered samples. However, the dynamic crystallization may also be readily studied by differential scanning calorimetry (dsc). Crystallization, remelting, and recrystallization to a more stable form may be observed when Hquid fat is solidified at a carefully controlled rate ia the iastmment. Enthalpy values and melting poiats for the various crystal forms are shown ia Table 3 (52). [Pg.130]

Electrophoresis (qv), ie, the migration of small particles suspended in a polar Hquid in an electric field toward an electrode, is the best known effect. If a sample of the suspension is placed in a suitably designed ceU, with a d-c potential appHed across the ceU, and the particles are observed through a microscope, they can all be seen to move in one direction, toward one of the two electrodes. AH of the particles, regardless of their size, appear to move at the same velocity, as both the electrostatic force and resistance to particle motion depend on particle surface this velocity can be easily measured. [Pg.390]

The concentration of is determined by measurement of the specific P-activity. Usually, the carbon from the sample is converted into a gas, eg, carbon dioxide, methane, or acetylene, and introduced into a gas-proportional counter. Alternatively, Hquid-scintiHation counting is used after a benzene synthesis. The limit of the technique, ca 50,000 yr, is determined largely by the signal to background ratio and counting statistics. [Pg.418]

Bromine ttifluoride is commercially available at a minimum purity of 98% (108). Free Br2 is maintained at less than 2%. Other minor impurities are HF and BrF. Free Br2 content estimates are based on color, with material containing less than 0.5% Br2 having a straw color, and ca 2% Br2 an amber-red color. Fluoride content can be obtained by controlled hydrolysis of a sample and standard analysis for fluorine content. Bromine ttifluoride is too high boiling and reactive for gas chromatographic analysis. It is shipped as a Hquid in steel cylinders in quantities of 91 kg or less. The cylinders are fitted with either a valve or plug to faciUtate insertion of a dip tube. Bromine ttifluoride is classified as an oxidizer and poison by DOT. [Pg.187]

RVP is a vapor pressure measurement at a fixed air/Hquid ratio of 4 and a temperature of 38°C. It is measured under conditions of water saturation. For samples which contain water-soluble components such as alcohols, ASTM D4953 is used. [Pg.182]

The existence of neon (Greek neos, new) was predicted, as was the existence of heavier members of the group. In 1898 krypton (Greek kTyptos, hidden) was discovered by spectroscopic examination of the residue from a sample of Hquid air. Neon was discovered in the same year. A month later, xenon (Greek xenos, strange) was isolated from the residue left after distillation of krypton. [Pg.4]

Other problems occur in the measurement of pH in unbuffered, low ionic strength media such as wet deposition (acid rain) and natural freshwaters (see Airpollution Groundwatermonitoring) (13). In these cases, studies have demonstrated that the principal sources of the measurement errors are associated with the performance of the reference electrode Hquid junction, changes in the sample pH during storage, and the nature of the standards used in caHbration. Considerable care must be exercised in all aspects of the measurement process to assure the quaHty of the pH values on these types of samples. [Pg.466]

Samples that contain suspended matter are among the most difficult types from which to obtain accurate pH readings because of the so-called suspension effect, ie, the suspended particles produce abnormal Hquid-junction potentials at the reference electrode (16). This effect is especially noticeable with soil slurries, pastes, and other types of colloidal suspensions. In the case of a slurry that separates into two layers, pH differences of several units may result, depending on the placement of the electrodes in the layers. Internal consistency is achieved by pH measurement using carefully prescribed measurement protocols, as has been used in the determination of soil pH (17). [Pg.467]

Other difficulties of measuring pH in nonaqueous solvents are the complications that result from dehydration of the glass pH membrane, increased sample resistance, and large Hquid-junction potentials. These effects are complex and highly dependent on the type of solvent or mixture used (1,5). [Pg.467]

Q are the absorbance and wavenumber, respectively, at the peak (center) of the band, p is the wavenumber, and y is the half width of the band at half height. Liquid band positions ate usually shifted slightly downward from vapor positions. Both band positions and widths of solute spectra are affected by solute—solvent interactions. Spectra of soHd-phase samples are similar to those of Hquids, but intermolecular interactions in soHds can be nonisotropic. In spectra of crystalline samples, vibrational bands tend to be sharper and may spHt in two, and new bands may also appear. If polarized infrared radiation is used, both crystalline samples and stressed amorphous samples (such as a stretched polymer film) show directional effects (28,29). [Pg.197]


See other pages where Samples hquids is mentioned: [Pg.302]    [Pg.135]    [Pg.302]    [Pg.135]    [Pg.1094]    [Pg.1136]    [Pg.45]    [Pg.55]    [Pg.69]    [Pg.142]    [Pg.147]    [Pg.331]    [Pg.384]    [Pg.440]    [Pg.134]    [Pg.277]    [Pg.426]    [Pg.426]    [Pg.431]    [Pg.193]    [Pg.379]    [Pg.404]    [Pg.442]    [Pg.13]    [Pg.15]    [Pg.287]    [Pg.467]    [Pg.104]    [Pg.197]    [Pg.198]    [Pg.199]    [Pg.201]    [Pg.201]    [Pg.209]    [Pg.407]    [Pg.510]    [Pg.510]   