Sample disposal

Forensic analysis is usually required for the collection of data in the course of determining whether legislation has been infringed. The customer requires that, above all, there is an unbroken chain of evidence from the time the samples were taken to the presentation of evidence in courts of law. In the laboratory this will include documentation and authorization for sample receipt, sample transfer, sub-sampling, laboratory notebooks, analytical procedures, calculations and observations, witness statements and sample disposal. All of these aspects can be called as evidence in court. [Pg.6]

Fluid sampling systems generally consist of four main sections, viz. the probe, the sample line, sample treatment and sample disposal. [Pg.523]

COC forms are usually printed as white originals with one or two attached carbon reproduction copies of different colors. A sequential number often (but not always) identifies each form this number is useful for sample tracking. The carbon copy stays at the project site as part of project records, and the original is sent with samples to the laboratory. The laboratory will in turn include a fully completed original COC form with the sample data package. (Technically, a fully completed COC form should include a record of sample disposal, but in reality this never happens because laboratories document sample disposal with internal records). [Pg.93]

For proper budgeting, inquire whether the laboratory charges a fee for samples put on hold, kept in storage for long periods of time, and for sample disposal. [Pg.211]

The unpaired electron with its spin S = 1/2 in a sample disposed into the resonator of the EPR spectrometer interacts magnetically a) with the external magnetic field H (Zeeman interaction) b) with the nuclear spin of the host atom or metal ion / (hyperfine interaction) c) with other electron spins S existing in the sample (dipole-dipole interaction). In the last case, electrons can be localized either at the same atom or ion (the so called fine interaction), for example in Ni2+, Co2+, Cr3+, high-spin Fe3+, Mn2+, etc., or others. These interac-tions are characterized energetically by the appropriate spin-Hamiltonian... [Pg.205]

Tetrachloroethane has a known toxicity, as described in the warning in the Method section. Do not pipette this or any other chemical by mouth, and avoid inhaling the vapor while withdrawing samples. Dispose of waste chemicals as instructed. [Pg.214]

The complete procedure for a single applied sample consists of several discrete steps sample withdrawal, needle wipe-off, predosage application of the sample, disposal of unrequired sample, and, finally, rinse. Sample volumes of 0.1 to 5 pL per spot can be applied by contact application however, for volumes of 0.5 to >50 pL, it uses spray-on application in the form of bands or rectangles (Fig. 6). [Pg.1387]

Although we did not attempt to collect the chlorosilanes, we found that the sample disposal/recycle selector on the pump inlet manifold, made collection of such sensitive compounds as Zn[Mo(CO)jCp]2 (2) into Ace Glass Co. No-Air vessels ( 3) quite easy. [Pg.26]

Sample Collection and Storage. This step in an analytical study offers many opportunities for loss of integrity of samples, and must be described in full detail. Precisely what tools will be used to acquire the samples Disposable scalpels, for example, are coated with an oil that can contaminate tissues. Metal tools obviously should not be used to take samples for trace metal determination. Good judgement can not be assumed details must be provided. [Pg.440]

Sample disposal options depend on the sample type and size. Liquid samples are mostly consumed during the analytical process and require minimal handling as waste. Sample residue should be archived in case re-analysis is required. When the sample results are validated and the client authorizes disposal, the sample residue is discharged to the holding tank. [Pg.273]

After data validation and sample release for disposal by the client, solid samples can be returned to the client or logged into the sample disposal database and packaged for disposal at an approved waste disposal facility. Samples must be disposed as either radiological or mixed waste, and not commingled with sanitary sewer or general landfill discharges. [Pg.273]

The situation described in field E is associated with a concentration of 1% at the level of the electrodes and a concentration of 20% in the internal zone. The results are significant we observe an electric blocking effect much larger for the sample disposing of three metallic zones than with the sample disposing of two metallic zones. [Pg.293]

Samples (disposable diapers with simulated stools or urine) b Si... [Pg.1460]


See other pages where Sample disposal is mentioned: [Pg.303]    [Pg.103]    [Pg.303]    [Pg.528]    [Pg.8]    [Pg.837]    [Pg.403]    [Pg.35]    [Pg.265]    [Pg.111]    [Pg.265]    [Pg.293]    [Pg.100]   
See also in sourсe #XX -- [ Pg.114 ]