Sample size, influence

MW frequency of 10 Hz. There are various considerations that influence the choice of the radiation frequency. Higher frequencies, which require higher magnetic fields, give inlierently greater sensitivity by virtue of a more favourable Boltzmaim factor (see equation (b 1.15.11)). However, several factors place limits on the frequency employed, so that frequencies in the MW region of the electromagnetic spectrum remain favoured. One limitation is the sample size at frequencies around 40 GHz the dimensions of a typical... [Pg.1558]

There are two ways in which the volume occupied by a sample can influence the Gibbs free energy of the system. One of these involves the average distance of separation between the molecules and therefore influences G through the energetics of molecular interactions. The second volume effect on G arises from the contribution of free-volume considerations. In Chap. 2 we described the molecular texture of the liquid state in terms of a model which allowed for vacancies or holes. The number and size of the holes influence G through entropy considerations. Each of these volume effects varies differently with changing temperature and each behaves differently on opposite sides of Tg. We shall call free volume that volume which makes the second type of contribution to G. [Pg.249]

Finally, we note that the size and shape of the particles of the packing, the packing technique, and column dimensions and configuration are additional factors which influence a GPC experiment. In addition, the flow rate, the sample size, the sample concentration, the solvent, and the temperature must all be optimized. Details concerning these considerations are found in analytical chemistry references, as well as in the technical literature of instrument manufacturers. [Pg.652]

Sample quantity to estimate moisture for specific material is influenced to various levels of significance by properties such as particle-size range as well as relative amounts or moisture distributed among denoted forms of retention. Practical sample size estimates require background knowledge of parameters derived from experience for specific materials. More detailed examination of moisture-sampling aspects is provided in reference texts (Pitard). [Pg.1758]

Samples must be introduced into the plasma in an easily vaporized and atomized form. Typically this requires liquid aerosols with droplet diameters less than 10 pm, solid particles 1-5 pm in diameter, or vapors. The sample introduction method strongly influences precision, detection limits, and the sample size required. [Pg.638]

Although sample size will most greatly influence the choice of column, the chemical and physical differences between TSK-GEL SW columns and TSKGEL PW columns will also affect choice. Eor example ... [Pg.130]

The thermal reactions of CaC204 H20 have been very fully investigated and this substance has been used as a thermal analysis reference material [1058], Dehydration, decomposition to the carbonate, and dissociation to CaO are all well separated, though kinetic characteristics are influenced by the presence of C02, 02 and H20 as well as by the reaction conditions, including heating rate, sample size, and sample container. Kinetic parameters for the oxalate decomposition reaction have been summarized by Gurrieri et al. [1059]. Values of E are close to 314 8 kJ mole-1. Decompositions [1057,1060,1061] of Sr (643—743 K) and Ba (663—743 K) oxalates involves some disproportion of CO, yielding residual carbon. [Pg.219]

Similarly, the number and types of tests completed will influence the cost in ways that can be very complex. Recently, the author was involved in designing a proof-of-principle study intended to assess the ability of a dietary supplement to enhance weight loss among subjects instructed to follow a reduced energy diet. Sample size calculations were run for two scenarios, the first using change in body weight as the primary outcome variable, the... [Pg.247]

Sample size may influence the analytical approach, e.g. 0.1 L of milk is easily obtained and extracted, but 10 mL of blood should be sufficient for monitoring purposes, and 5 g of fat is already the upper limit for an efficient fat cleanup by partition or gel permeation chromatography (GPC). [Pg.55]

Figure 1. Schematic diagram showing a TRU-spec extraction chromatography method for separation of uranium, thorium, protactinium, and radium from a single rock aliquot. Further purification for each element is normally necessary for mass spectrometric analysis. Analysis of a single aliquot reduces sample size requirements and facilitates evaluation of uranium-series dating concordance for volcanic rocks and carbonates. For TIMS work where ionization is negatively influenced by the presence of residual extractant, inert beads are used to help remove dissolved extractant from the eluant. Figure 1. Schematic diagram showing a TRU-spec extraction chromatography method for separation of uranium, thorium, protactinium, and radium from a single rock aliquot. Further purification for each element is normally necessary for mass spectrometric analysis. Analysis of a single aliquot reduces sample size requirements and facilitates evaluation of uranium-series dating concordance for volcanic rocks and carbonates. For TIMS work where ionization is negatively influenced by the presence of residual extractant, inert beads are used to help remove dissolved extractant from the eluant.
Another advantage of the micro-LC approach is that the required sample size is minimal, so the sample can be drawn from a 1-1 laboratory scale reactor without influencing the reactor composition. The ISCO pLC-500 microflow syringe pump has proven to be reliable and reproducible in evaluations in our laboratory. Capillary liquid columns have been fabricated on planar devices such as silicon to form a miniaturized separation device.19... [Pg.92]

A useful fingerprint of an active TS-1 catalyst is the particle size of the titanosilicate (<0.4 pm). Although the particle size influences the catalytic activity of all molecular sieves, it is especially so in the case of TS-1 and due care should be exercised in comparing samples varying in particle size (89,90). [Pg.34]

Johnson, L. K., Brown, M. B., Carruthers, E. A., Ferguson, J. A., Dombek, P. E., and Sadowsky, M. J. (2004). Sample size, library composition, and genotypic diversity among natural populations of Escherichia coli from different animals influence accuracy of determining sources of fecal pollution. Appl. Environ. Microbiol. 70,4478M485. [Pg.200]

Statistical analysis of fetal and neonatal data should be conducted with careful consideration of study design, the endpoint under consideration, sample size, effects of gender, and the influence of litter on analytical outcome. It is critical that litter-mates not be treated as independent observations in the statistical analysis (13). [Pg.54]

Generally speaking these sample size considerations are independent of any formal interim comparisons of the treatments, be they efficacy or futility. Given the need to maintain blinding it is also advisable not to involve the DMC in these re-evaluations their potential knowledge of the unfolding data in an unblinded way could well influence their view on a change in the sample size - they know too much ... [Pg.224]

Several factors influence TGA data. Sample size and shape affect the rate and efficiency of decomposition. Powdered versus solid bulk samples will have different decomposition profiles due to the differing surface areas from which exiting decomposition products can leave the sample and be registered as mass losses. Similarly, the packing of the sample in the pan must be even and reproducible from run to run. Loosely distributed particles will heat more evenly and evolve volatilized products more evenly than mounded or densely packed samples. This can be especially important when looking at determinations of residual solvents, moisture or diffusion controlled losses such as plasticizer in the samples. [Pg.117]


See other pages where Sample size, influence is mentioned: [Pg.2242]    [Pg.330]    [Pg.74]    [Pg.15]    [Pg.255]    [Pg.437]    [Pg.227]    [Pg.408]    [Pg.192]    [Pg.302]    [Pg.822]    [Pg.829]    [Pg.118]    [Pg.47]    [Pg.53]    [Pg.221]    [Pg.72]    [Pg.74]    [Pg.246]    [Pg.126]    [Pg.146]    [Pg.71]    [Pg.102]    [Pg.152]    [Pg.320]    [Pg.381]    [Pg.34]    [Pg.431]    [Pg.318]    [Pg.53]    [Pg.452]    [Pg.25]    [Pg.309]    [Pg.229]   
See also in sourсe #XX -- [ Pg.25 , Pg.26 , Pg.43 , Pg.44 , Pg.66 , Pg.107 ]