Sample preparation advantages

In Figure 3, the active steroid (triamcinolone acetonide) and preservative (benzyl alcohol) are determined from a steroid cream. The higher molecular weight components of the cream base are well separated from the analytes. The ability to elute all the components of a cream or ointment in a SMGPC analysis gives an important sample preparation advantage over competing separation techniques. [Pg.177]

A major advantage of this hydride approach lies in the separation of the remaining elements of the analyte solution from the element to be determined. Because the volatile hydrides are swept out of the analyte solution, the latter can be simply diverted to waste and not sent through the plasma flame Itself. Consequently potential interference from. sample-preparation constituents and by-products is reduced to very low levels. For example, a major interference for arsenic analysis arises from ions ArCE having m/z 75,77, which have the same integral m/z value as that of As+ ions themselves. Thus, any chlorides in the analyte solution (for example, from sea water) could produce serious interference in the accurate analysis of arsenic. The option of diverting the used analyte solution away from the plasma flame facilitates accurate, sensitive analysis of isotope concentrations. Inlet systems for generation of volatile hydrides can operate continuously or batchwise. [Pg.99]

When the spectral characteristics of the source itself are of primary interest, dispersive or ftir spectrometers are readily adapted to emission spectroscopy. Commercial instmments usually have a port that can accept an input beam without disturbing the usual source optics. Infrared emission spectroscopy at ambient or only moderately elevated temperatures has the advantage that no sample preparation is necessary. It is particularly appHcable to opaque and highly scattering samples, anodized and painted surfaces, polymer films, and atmospheric species (135). The interferometric... [Pg.315]

Immunoassays. Immunoassays (qv) maybe simply defined as analytical techniques that use antibodies or antibody-related reagents for selective deterrnination of sample components (94). These make up some of the most powerflil and widespread techniques used in clinical chemistry. The main advantages of immunoassays are high selectivity, low limits of detection, and adaptibiUty for use in detecting most compounds of clinical interest. Because of their high selectivity, immunoassays can often be used even for complex samples such as urine or blood, with Httle or no sample preparation. [Pg.247]

Theoretical and applied aspects of microwave heating, as well as the advantages of its application are discussed for the individual analytical processes and also for the sample preparation procedures. Special attention is paid to the various preconcentration techniques, in part, sorption and extraction. Improvement of microwave-assisted solution preconcentration is shown on the example of separation of noble metals from matrix components by complexing sorbents. Advantages of microwave-assisted extraction and principles of choice of appropriate solvent are considered for the extraction of organic contaminants from solutions and solid samples by alcohols and room-temperature ionic liquids (RTILs). [Pg.245]

A major advantage of static SIMS over many other analytical methods is that usually no sample preparation is required. A solid sample is loaded directly into the instrument with the condition that it be compatible with an ultrahigh vacuum (10" —10 torr) environment. Other than this, the only constraint is one of sample size, which naturally varies from system to system. Most SIMS instruments can handle samples up to 1-2 inches in diameter. [Pg.551]

There are advantages to direct solid sampling. Sample preparation is less time consuming and less prone to contamination, and the analysis of microsamples is more straightforward. However, calibration may be more difficult than with solution samples, requiring standards that are matched more closely to the sample. Precision is typically 5% to 10% because of sample inhomogeneity and variations in the sample vaporization step. [Pg.639]

Most of the transition elements that are of primary interest in the semiconductor industry such as Fe, Cr, Mn, Co, and Ni, can be analyzed with very low detection limits. Second to its sensitivity, the most important advantage of NAA is the minimal sample preparation that is required, eliminating the likelihood of contamination due to handling. Quantitative values can be obtained and a precision of 1-5% relative is regularly achieved. Since the technique measures many elements simultaneously, NAA is used to scan for impurities conveniently. [Pg.672]

The advantages of LA are now well-known - no sample preparation is needed, conducting and non-conducting samples of arbitrary structure can be analyzed directly, spatial resolution up to a few microns can be obtained, high vacuum conditions are not required, rapid simultaneous multi-element analysis is possible, and it is possible to obtain complete analytical information with a single laser pulse. A brief overview of the potential and limitations of LA will be given in this chapter. [Pg.231]

The main advantages of electrothermal atomisers are that (a) very small samples (as low as 0.5 pL) can be analysed (b) often very little or no sample preparation is needed, in fact certain solid samples can be analysed without prior dissolution (c) there is enhanced sensitivity, particularly with elements with a short-wavelength resonance line in practice there is an improvement of between 102- and 103-fold in the detection limits for furnace AAS compared with flame AAS. [Pg.788]

Porous materials, such as silica and alumina, have thermal diffusion lengths of approximately 10 m, which is much less than the typical thickness of pressed discs. The small thermal diffusion length gives photoacoustic spectroscopy a larger dynamic range than transmission methods when applied to powdered samples. An additional advantage is the ease of sample preparation, since photoacoustic spectroscopy uses powdered samples with no special preparation required. [Pg.450]

Whilst for the analysis of plant material for cannabinoids both GC and HPLC are commonly used, in analytical procedures the employment of GC-based methods prevails for human forensic samples. Nonetheless, the usage of HPLC becomes more and more of interest in this field especially in combination with MS [115-120]. Besides the usage of deuterated samples as internal standards Fisher et al. [121] describe the use of a dibrominated THC-COOH (see 7.5). The usage of Thermospray-MS and electrochemical detection provide good performance and can replace the still-used conventional UV detector. Another advantage in the employment of HPLC rather than GC could be the integration of SPE cartridges, which are needed for sample preparation in the HPLC-system. [Pg.31]

Sample preparation techniques vary depending on the analyte and the matrix. An advantage of immunoassays is that less sample preparation is often needed prior to analysis. Because the ELISA is conducted in an aqueous system, aqueous samples such as groundwater may be analyzed directly in the immunoassay or following dilution in a buffer solution. For soil, plant material or complex water samples (e.g., sewage effluent), the analyte must be extracted from the matrix. The extraction method must meet performance criteria such as recovery, reproducibility and ruggedness, and ultimately the analyte must be in a solution that is aqueous or in a water-miscible solvent. For chemical analytes such as pesticides, a simple extraction with methanol may be suitable. At the other extreme, multiple extractions, column cleanup and finally solvent exchange may be necessary to extract the analyte into a solution that is free of matrix interference. [Pg.630]

SFE of fruits and vegetables and meat products has been reported, but the sample preparation techniques necessary to obtain reproducible results are extremely time consuming. Solid absorbents such as Hydromatrix, Extrelut " anhydrous magnesium sulfate or absorbent polymers are required to control the level of water in the sample for the extraction of the nonpolar pesticides. Without the addition of Hydromatrix, nonpolar pesticides cannot penetrate the water barrier between the sample particles and the supercritical CO2. The sample is normally frozen and the addition of dry-ice may be required to reduce losses due to degradation and/or evaporation. Thorough reviews of the advantages and limitations of SFE in pesticide residues... [Pg.730]

In addition to instrumental improvements, various approaches have been used to improve the purity or geometry of sources of natural samples for gamma spectrometric measurement. For example, improvements in source preparation for " Th measurement in water and sediment samples by gamma spectrometry are discussed in Cochran and Masque (2003). It should be emphasized that one of the main advantages of gamma spectrometry is ease of use, since in many cases samples may be analyzed directly or with significantly reduced sample preparation compared to alpha, beta, or mass spectrometric techniques. [Pg.31]

The role of extraction in sample preparation consists in analyte concentration, clean-up and change of physical form. Extraction procedures, though time-consuming, have these advantages ... [Pg.58]

The advantages of automation of extraction under reflux versus manual sample preparation are well illustrated for HDPE/(Irganox 1010, Irgafos 168) (Table 3.7) [118]. No spikes were observed in the former case, as opposed to the latter. Boiling under reflux is considered by some [4] as the best all round conventional extraction method. [Pg.67]


See other pages where Sample preparation advantages is mentioned: [Pg.320]    [Pg.320]    [Pg.286]    [Pg.3]    [Pg.49]    [Pg.209]    [Pg.148]    [Pg.315]    [Pg.11]    [Pg.102]    [Pg.436]    [Pg.87]    [Pg.592]    [Pg.701]    [Pg.217]    [Pg.232]    [Pg.232]    [Pg.194]    [Pg.780]    [Pg.28]    [Pg.152]    [Pg.403]    [Pg.194]    [Pg.9]    [Pg.202]    [Pg.63]    [Pg.450]    [Pg.80]    [Pg.308]    [Pg.309]    [Pg.417]    [Pg.428]    [Pg.441]    [Pg.902]    [Pg.299]   