Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Direct loading

Ceramics, without exception, are hard, brittle solids. When designing with metals, failure by plastic collapse and by fatigue are the primary considerations. For ceramics, plastic collapse and fatigue are seldom problems it is brittle failure, caused by direct loading or by thermal stresses, that is the overriding consideration. [Pg.166]

Fig. 1.19 Potential-pH diagram for copper in solutions containing and (NH4>2S04 (after Mattson ) with superimposed times to fracture Tf of direct-loaded a-brass wires held at various potentials in the solution of pH 7-2 the specimen without external polarisation had Ff = 3y h (after Hoar and Booker S)... Fig. 1.19 Potential-pH diagram for copper in solutions containing and (NH4>2S04 (after Mattson ) with superimposed times to fracture Tf of direct-loaded a-brass wires held at various potentials in the solution of pH 7-2 the specimen without external polarisation had Ff = 3y h (after Hoar and Booker S)...
The response of the overall structure may be determined by the same techniques described above. The difference between directly loaded elements and supporting elements is the force amplitude and pulse shape of the applied loading. The loading on the overall stmctural system is determined from the reaction force time histories from directly loaded elements. Note that the loads on supporting members, frames, or shear walls, in some cases, may comprise reaction forces from pressures acting on the front and back faces of the structure simultaneously, taking into account the different arrival times of the blast wave. [Pg.136]

Silicon linker 76 was used for direct loading of aromatic compounds to supports for the assembly of pyridine-based tricyclics (Scheme 39) [87], Following the initial coupling of an aromatic bromide to the resin by halogen/metal exchange in the presence of tert-butyl lithium, a... [Pg.208]

Woolard FX, Paetsch J, Ellman JA. A silicon linker for direct loading of aromatic compounds to supports. Traceless synthesis of pyridinc-bascd tricylics. J Org Chem 1997 62 6102-6103. [Pg.224]

In the simplest scheme of 2D HPLC, effluent of the first dimension (lst-D) was directly loaded into an injector loop (500 pL) of the 2nd-D HPLC for 28 s, and 2 s were allowed for injection. This operation was accompanied by the loss of lst-D effluent for 2 s out of 30 s in each cycle. The flow rate of 10 mL/min allowed the elution of solutes having retention factors (k values) up to 8 for the 2nd-D within the 30-s separation window, with f0 of 3.5 s. Figure 7.7 a and b shows the chromatograms for the 1 st-D and the 2nd-D, respectively, obtained for a mixture of hydrocarbons and benzene derivatives. The lst-D chromatogram showed many overlapping peaks. PAHs were eluted as mixtures from the FR column, and some are separated in the 2nd-D. [Pg.161]

F. X. Woolard, J. Paetsch, J. A. Ellman, A Silicon Linker for Direct Loading of Aromatic Compounds to Supports. Traceless Synthesis of Pyridine-Based Tricyclics , J. Org Chem. 1997, 62, 6102-6103. [Pg.77]

Resulting directions (loading vectors) are orthogonal as in classical PCA. [Pg.81]

Lee T, Papanastassiou DA, Wasserburg GJ (1977) Mg and Ca isotopic study of individual microscopic crystals from the Allende meteorite by the direct loading technique. Geochim Cosmochim Acta 41 1473-1485 Lee T, Russell WA, Wasserburg GJ (1979) Calcium isotopic anomalies and the lack of aluminum-26 in an unusual Allende inclusion. Appl J Lett 228(L93-L98) 661-662 Marshall BD, DePaolo DJ (1982) Precise age determinations and petrogenetic studies using the K-Ca method. Geochim Cosmochim Acta 46 2537-2545... [Pg.286]

Spots from thin-layer chromatography (TLC) plates may often be used directly in the mass spectrometer without eluting thus for air-sensitive compounds, when TLC is done in a glove box, a concentric tube may be directly loaded with the unknown plus support the concentric tube is recommended because it minimizes loss of silica gel into the ion source. [Pg.239]

T. Ruhland, K. Andersen and H. Pedersen, Selenium-linking strategy for traceless solid-phase synthesis Direct loading, aliphatic C-H bond formation upon cleavage and reaction monitoring by gradient MAS NMR spectroscopy, J. Org. Chem., 1998, 63, 9204-9211. [Pg.290]

Metal affinity columns can be used for the purification of antibodies with a hexa-Histidine tag. Immobilized metal affinity chromatography is incompatible, in our own experience, with direct loading of antibodies in supernatants... [Pg.491]

Note. (1) The reaction may be monitored by g.l.c. by the direct loading of a sample (0.1 /d) on to an S.E. 30-column, 1.5 m, held at 170 °C (nitrogen flow 40ml/minute). The retention time of 1-iodoheptane is 52 seconds that of heptyl o-phenylene phosphite under the same conditions is 4 minutes. [Pg.570]

The polymer-gas solution to be tested is prepared separately, and is loaded into the rheometer barrel as a well-mixed, equilibrated sample. The loading method depends on whether the polymer itself is a liquid or a solid at room temperature. For liquid polymers such as PDMS, Gerhard (1994) developed a sealed module that attached to the top of the rheometer barrel, with a side valve though which an equilibrated liquid polymer-gas sample is injected. For solid polymers such as polystyrene, Kwag (1998) found that the diffusion of gas from solid pellets at room temperature was sufficiently slow to allow direct loading of the sample as solid pellets pre-... [Pg.176]

The analyte binding efficiency is matrix dependent. Some matrices, such as urine and tissue extracts, can be directly loaded onto the column, other matrices such as milk may need sample processing prior to loading onto an immunoaffinity column. The simplest sample preparation method is dilution this method has been applied to serum, liver, and kidney extracts after removal of particulates. Sometimes dilution alone is not sufficient to eliminate the matrix effect and classical sample preparation techniques (solvent/solvent extraction, solid phase extraction, etc.) will be necessary prior to immunoaffinity chromatography. We found milk often needs this type of treatment. [Pg.307]

Small drugs, as are most pharmaceuticals, can be directly loaded in the preformed films [56-58], Schneider demonstrated that chitosan/hyaluronic acid (CHI/HA)... [Pg.138]

Optimized, computer-based load allocation will direct load increases to the most cost-effective chiller, while sending the load decreases to the least cost-effective chiller. [Pg.161]

A material that is subjected to cyclic application of stresses may fail after a large number of load cycles without nearly reaching the maximum failure stress of direct loading. The effect of such cyclic stresses is to initiate microscopic cracks at centres of stress concentration within the material or on the surface, and subsequently to enable these cracks to propagate, leading to eventual failure. For high stress amplitudes less cycles are needed for failure than for low stress amplitudes. For high frequencies less cycles are needed for... [Pg.469]


See other pages where Direct loading is mentioned: [Pg.177]    [Pg.311]    [Pg.83]    [Pg.140]    [Pg.635]    [Pg.667]    [Pg.60]    [Pg.769]    [Pg.112]    [Pg.96]    [Pg.284]    [Pg.298]    [Pg.264]    [Pg.264]    [Pg.60]    [Pg.29]    [Pg.610]    [Pg.628]    [Pg.303]    [Pg.142]    [Pg.8]    [Pg.152]    [Pg.154]    [Pg.162]    [Pg.451]    [Pg.195]    [Pg.263]    [Pg.524]   
See also in sourсe #XX -- [ Pg.494 ]




SEARCH



© 2024 chempedia.info