Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample linearity

Because acceptable recoveries were obtained at O.Olmgkg", the method LOQ is 0.01 mg kg for flucarbazone-sodium and O.Olmgkg" for Af-desmethyl flucarbazone in all wheat samples. Linearity curves in both solvent and matrix blanks were mn from 0.005 to 0.100 mg kg . Because 0.005 mg kg of each analyte was reliably detected, the method limit of detection (LOD) was 0.005 mg kg in all wheat samples. [Pg.495]

The instrument yields the absorbance by ratioing the transmitted intensities in the presence and absence of sample. Linearity is only observed for weak concentrations (typically below 3 ppm). The methods used, comparable to those used in molecular absorption spectrophotometry, involve classical protocols methods using a calibration curve or standard additions, as long as the range of concentrations stays within the linear conditions of absorbance. [Pg.257]

The most critical part of the method selection is determining the relative merits of seemingly diverse HPLC separations. Unfortunately, there is no standard against which all HPLC methods for vitamins are presently compared. However, there are indicators of assay reliability for which the analyst should look. These include measures of precision, accuracy, and reproducibility recoveries from spiked food samples linearity of calibration limits of detection measures of peak purity comparisons with existing recognized methods and results of collaborative or interlaboratory trials (9,10). [Pg.405]

While these are two separate and distinct activities, each must complement the other to ensure a quality program. Day to day quality control in the laboratory is the obligation of the chemist. The chemist develops the methods, calibrates the instruments, and with management approval develops the standard operating procedures for the laboratory. Quality control is running duplicate samples, reagent blanks, fortification samples, linearity checks and confirmatory analyses. [Pg.44]

A protocol for in vitro transcription used in our laboratory is given below. Rapid plasmid minipreparations made by alkaline lysis without RNase treatment are usually sufficient to prepare DNA templates. DNA samples linearized by restriction digestion are extracted with chloroform, and precipitated with ethanol, and 0.2 to 0.5 /ig of DNA dissolved in 1 pil of distilled water is used per assay. Contamination with RNases must be avoided during the following steps. The reaction mixture for eight reactions is prepared at room temperature to avoid precipitates. [Pg.500]

Samples. Linear polurethane block copolymers with hard segments composed of 2,4- or 2,6-TDI, and 1,4-butanediol, BD, and either 1040 or 2060 molecular weight poly (tetramethylene oxide), PTMO, soft segments were supplied through the courtesy of N. S. Schneider of the Army Materials and Mechanics Research Center, Watertown, MA. These polymers were prepared by a two-step process, first an endcapping of the PTMO with a 5% molar excess of TDI, followed by chain extension... [Pg.104]

The key to controlling sample dispersion in air-segmented flow analysis is the addition of confluent streams. After the confluence point, an increase in the length of each plug (Eq. 3.12) leads to an increase in the length of the entire sample zone. This does not result in a broader recorded peak, however, because the sample linear speed is... [Pg.155]

The energy of a laser pulse is absorbed by the electrons of the material. The absorption mechanism is different for opaque and transparent samples. Linear absorption is the main contribution in opaque materials (e.g., metals) whereas absorption has to be realized by nonlinear processes in transparent materials (e.g., dielectrics). These nonlinear processes are avalanche and multiphoton ionization [20-25]. After electronic excitation, the energy is transferred to the lattice and heats it up to boiling and/or to vaporization temperature. Then, electrons and lattice are in thermal equilibrium. The transfer time of the electronic energy to the lattice (electron-phonon-relax-ation time) is of the order of picoseconds [26]. [Pg.260]

Response Detection limit for sample Linear range Flow sensitive Temperature sensitive Useful with gradient Favourable samples % Usage... [Pg.291]

This validation parameter can be defined as the ability of an analytical procedure to yield test results which are directly proportional to the concentration of the analyte in the sample . Linearity is evaluated across the range of the method. Five different concentrations are recommended by the ICH Guidance. For example, for a typical... [Pg.167]

Figure 6. Resonant frequency change as a function ofE. colt concentration. Plot of the sensor response data versus the log ofE. coli concentration in the beef samples. Linear behavior is observedfor sample concentrations ranging from 100- 10,000 cells/mL. Data are from reference (29). Figure 6. Resonant frequency change as a function ofE. colt concentration. Plot of the sensor response data versus the log ofE. coli concentration in the beef samples. Linear behavior is observedfor sample concentrations ranging from 100- 10,000 cells/mL. Data are from reference (29).
Slowly dried samples linear regression for points at XcaO o Fast dried samples linear r ession for all data points... [Pg.1057]

It should be mentioned that every substance needs heat to change the temperature. Heating a sample linearly needs a heat flow rate, which is proportional to the heat capacity and the heating rate. Consequently, the steady-state heat flow rate measured in the absence of any reaction or transition is never zero in a scanning calorimeter. [Pg.191]

Gutes et al. [113] have described an automated procedure based on voltammetric electronic tongue formed by a biosensor array for the determination of glucose in fruit juice samples. Linear sweep voltammetric signals were obtained with high selectivity and artificial neural networks were used as the modeling tool. [Pg.65]


See other pages where Sample linearity is mentioned: [Pg.703]    [Pg.6]    [Pg.270]    [Pg.449]    [Pg.207]    [Pg.192]    [Pg.84]    [Pg.95]    [Pg.384]    [Pg.222]    [Pg.91]    [Pg.13]    [Pg.140]    [Pg.8]    [Pg.222]    [Pg.552]    [Pg.169]    [Pg.450]    [Pg.347]    [Pg.7]    [Pg.133]    [Pg.520]    [Pg.708]    [Pg.604]    [Pg.339]    [Pg.486]    [Pg.76]    [Pg.571]    [Pg.664]    [Pg.166]    [Pg.218]    [Pg.42]    [Pg.110]    [Pg.60]    [Pg.61]    [Pg.62]   
See also in sourсe #XX -- [ Pg.365 ]




SEARCH



Linear controllers sampling

Non-linear Sampling

Sample Linearized Dose-Response Curves for Threshold and Nonthreshold Responses

© 2024 chempedia.info